In this study the investigators plan to enroll a total of 25 evaluable volunteers (volunteer population) for the development and optimization of perforator imaging protocols and 50 evaluable clinical patients receiving flap procedures at OSUMC for the clinical validation of the optimized protocol. No extrinsic MR contrast agent will be injected. Clinical patients' MRI images will be evaluated independently by radiologists and plastic surgeons and compared to the clinical CTA images.
The overall objective of this pilot study is to develop and optimize preoperative MRA imaging protocols for various perforators commonly used in flap surgery with phantoms and healthy volunteers and to obtain clinical validation of the optimized protocols with a group of patients receiving flap surgery at The OSU Wexmer Medical Center. Data obtained in this study may also serve as the basis for statistical planning of future clinical trials. Based on previous experience with other magnetic resonance imaging (MRI) techniques, the investigators hypothesize that optimal MRA images can only be obtained with a carefully selected combination of imaging hardware, acquisition, and postprocessing factors. The main objective of this pilot study is to determine this optimal combination through the comparison of image between different combinations. The secondary objective of this pilot study is to evaluate, both qualitatively and quantitatively, the quality of the optimized MRA images and compare them with clinical CTA images. The primary hypothesis is that the quality of the optimized MRA images is at least comparable to that of the CTA images. The quantitative measurements obtained from this pilot population will also serve as the preliminary data for future studies and be used in statistical calculations that determine their study population.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Healthy volunteer population | Experimental | We plan to enroll 25 healthy volunteers. |
|
| Patient population | Experimental | We plan to enroll 50 clinical patients who are receiving flap procedures at the Ohio State Medical Center. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| MRI Scan | Device | Study participants will be scanned with a 3.0 Tesla Phillips Ingenia CX whole body clinical MRI system located at the Wright Center of Innovation at The Ohio State University Medical Center. Anatomical and angiographic MR images will be acquired for one of the most commonly used flap surgery donor perforators including but not limited to: the deep inferior epigastric perforators (DIEP); the superior gluteal arter perforators (SGAP); the inferior gluteal artery perforators (IGAP); the thoracodorsal artery perforators (TDAP); the anterolateral thigh perforators (ATL). |
| Measure | Description | Time Frame |
|---|---|---|
| image quality | assessed by blinded readers | through study completion, on average 2-5 years |
| Artifacts in MRI images assessed by experienced readers | assessed by blinded readers | through study completion, on average 2-5 years |
| Vessel detectability in MRI assessed by experienced readers | assessed by blinded readers | through study completion, on average 2-5 years |
| Image noise as a measure of image quality assessed by quantitative measures | assessed region of interest over target tissue and background | through study completion, on average 2-5 years |
| Measure | Description | Time Frame |
|---|---|---|
| Anatomy accuracy | Location on images | 60 min |
| Vascular network continuity | Location on images | 60 min |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael V Knopp, MD, PhD | Ohio State University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Martha Morehouse Medical Plaza | Columbus | Ohio | 43221 | United States | ||
| The Ohio State University Hospital |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot | Yes | No | No | Study Protocol | Nov 13, 2017 | May 18, 2018 |
Not provided
Two populations are being investigated in this trial; a healthy volunteer population and a patient population. Each population will receive an MRI scan.
Not provided
Not provided
Not provided
Not provided
|
| Perforator branching pattern | Location on images | 60 min |
| Potential Clinical Use of the MRI Images for Clinical Decision making | Clinical reader assessment | Baseline |
| Signal-to-noise ratio (SNR) | ROI based assessment | Baseline |
| Contrast-to-noise ratio (CNR) to muscle and fat | ROI based assessment | Baseline |
| Perforator size | Location on images | 60 min |
| Length of perforator intramuscular course | Location on images | 60 min |
| Columbus |
| Ohio |
| 43221 |
| United States |
| Prot_000.pdf |
| ID | Term |
|---|---|
| D008279 | Magnetic Resonance Imaging |
| ID | Term |
|---|---|
| D014054 | Tomography |
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided