To control pain after total knee replacement surgery a catheter (tubing) is sometimes inserted into an anatomic space containing nerves that provide sensation to parts of the knee. This space is called the adductor canal.
The catheters often stop working before we remove them for unclear reasons. The investigators think this is because the catheters become dislodged from where it was meant to be. This could be due to repeated movements of the catheter tip brought on by patients contracting their leg muscles when they ambulate or perform physio.
The investigators want to confirm this by measuring the distance from a fixed spot on the patient's thigh to the adductor canal using an ultrasound machine. The leg will be measured in various positions to simulate muscle movements. A significant change in the distance could possibly contribute to catheter dislodgement and result in catheter failure.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| TKA Patients |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Measurements Using Ultrasound | Other | Ultrasound measurements will be made in 5 positions. The ultrasound probe will be measuring from a fixed external location of the thigh. The 5 positions include: external rotation, neutral, manual tissue external rotation, straight leg raise at 30 degrees and hip/knee flexion at 90 degrees. |
| Measure | Description | Time Frame |
|---|---|---|
| Skin to Adductor Canal Distance Disparity | The largest distance disparity as measured from the 5 different leg positions | Measurements will be made on the day of surgery, no other assessment or follow up needed |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
We are recruiting patients undergoing total knee replacement. Per hospital protocol, patients will receive a spinal anesthetic and adductor canal block as part of their anesthetic regimen. After surgery, previously consented patients will have their skin to adductor canal distance measured by ultrasound in 5 different positions.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jason Wilson, MD | University of British Columbia | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of British Columbia Hospital | Vancouver | British Columbia | V6T 2B5 | Canada |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 32385824 | Derived | Tholin M, Wilson J, Lee S, Tang R, Sawka A, Vaghadia H. Impact of leg movement on skin-adductor canal distance: a potential cause for catheter tip displacement? Can J Anaesth. 2020 Aug;67(8):936-941. doi: 10.1007/s12630-020-01693-6. Epub 2020 May 8. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Patients older than 18 years of age undergoing elective total knee arthroplasty who were able to give informed consent
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | TKA Patients | Measurements Using Ultrasound: Ultrasound measurements will be made in 5 positions. The ultrasound probe will be measuring from a fixed external location of the thigh. The 5 positions include: external rotation, neutral, manual tissue external rotation, straight leg raise at 30 degrees and hip/knee flexion at 90 degrees. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | TKA Patients | Measurements Using Ultrasound: Ultrasound measurements will be made in 5 positions. The ultrasound probe will be measuring from a fixed external location of the thigh. The 5 positions include: external rotation, neutral, manual tissue external rotation, straight leg raise at 30 degrees and hip/knee flexion at 90 degrees. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Skin to Adductor Canal Distance Disparity | The largest distance disparity as measured from the 5 different leg positions | Posted | Mean | 90% Confidence Interval | centimeters | Measurements will be made on the day of surgery, no other assessment or follow up needed |
|
|
Adverse event date was not collected since this was an observational study
There was no opportunity for adverse event since the object of the study was ultrasound measurements of anatomy.
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | TKA Patients | Measurements Using Ultrasound: Ultrasound measurements will be made in 5 positions. The ultrasound probe will be measuring from a fixed external location of the thigh. The 5 positions include: external rotation, neutral, manual tissue external rotation, straight leg raise at 30 degrees and hip/knee flexion at 90 degrees. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Marcus Tholin | Vancouver General Hospital | 604-875-4111 | marcus.tholin@vch.ca |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Apr 15, 2019 | Apr 15, 2019 | Prot_SAP_000.pdf |
Not provided
Not provided
Not provided
Not provided
|
| Participants |
|
| Age, Continuous | Mean | Full Range | years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race and Ethnicity Not Collected | Race and Ethnicity were not collected from any participant. | Count of Participants | Participants |
|
| Region of Enrollment | Count of Participants | Participants |
|
| Participants |
|
|
| 0 |
| 0 |
| 0 |
| 0 |
| 0 |