Randomized Controlled Study to Evaluate Safety and Efficacy of Ologen® Collagen Matrix Versus Mitomycin-C in Patients With Juvenile-onset Open Angle Glaucoma
Randomized Controlled Study to Evaluate Safety and Efficacy of Ologen® Collagen Matrix Versus Mitomycin-C in Patients With Juvenile-onset Open Angle Glaucoma
To the best of Investigator knowledge, no studies to this date have compared the safety and efficacyof ologen® Collagen Matrix to MMC in exaggerated healing response among JOAG patients. Given that,filtration surgery is usually less successful in patients with juvenile glaucoma; the purpose of this study is to compare these two adjuvant therapies in exaggerated healing response among JOAG patients. Investigator hypothesis is that trabeculectomy with ologen® Collagen Matrix would be as effective as MMC in IOP control, with prominent bleb morphology as compared to MMC bleb.
Standard trabeculectomy All trabeculectomy surgeries will be performed under peribulbar anesthesia.Under aseptic surgical technique, superior rectus suture will be placed using 4-0 silk and a fornix-based conjunctival flap will be performed. Sub-Tenon dissection and hemostasis may be performed as required.A half-thickness 4 x 4mm rectangular/ triangular scleral flap will be dissected up to clear cornea, and a 2 × 2 mm deep scleral block will be excised and peripheral iridectomy will be performed. The scleral flap will be closed with one or two 10-0 nylon sutures and conjunctiva will be closed with 8-0 vicryl suture. Releasable sutures may be applied to the scleral flap if needed.
ologen® Collagen Matrix ologen® Collagen Matrix approved by Indian health authority with registration numberof MD-1517 (valid till Mar-15-2018) will be provided by Aeon Ajanta India Pvt. Ltd. free of cost for this clinical research only.
The following table summarizes the model number, shape and manufacturer of ologen® Collagen Matrix to be used in this clinical research.
Product Model Shape Size Manufacturer Country of Origin Product Registration ologen® Collagen Matrix 830601 Round cylindrical 6mm (diameter) x 2mm (thickness) Aeon Astron Europe B. V. The Netherlands MD-1517 (valid till Mar-15-2018)
Mitomycin C Mitomycin-C Kyowa®; Kyowa Hakko Kogyo Co., Ltd. will be used. 0.02% solution of MMC will be prepared freshly on the day of planned surgery.
Inclusion Criteria:
Exclusion Criteria:
1. Patients with steroid-induced glaucoma and other types of secondary open angle glaucoma 2. Juvenile-onset Open Angle Glaucoma eyes that underwent trabeculectomy with MMC or had a previous filtering surgery 3. Patients with any other ocular disease that may expose them to an undue risk of a significant adverse event during the course of the study, including but not limited to ocular cancer, trauma, corneal surface damage or other conditions as determined by the clinical judgment of the investigator 4. Patient with single functional eye 5. Participation in any study 30 days prior to trabeculectomy 6. Pregnant or breast-feeding women
-