Hemodynamic monitoring, especially cardiac output assessment, is a key feature for the management of critically ill patients. Although the use of invasive methods, such as thermodilution with a pulmonary artery catheter, remains the GOLD standard for the evaluation of the cardiac output, several non-invasive techniques are currently used in practice. An acceptable estimation of the cardiac output can be made by standard transthoracic echocardiography. Cardiac output can be calculated from subaortic velocity time integral (VTI). However, this technique requires a trained operator and depends on the echogenicity of the patient. The best method for assessing cardiac output depends on the patient's needs, the clinical scenario and the physician's experience with the monitoring device itself. No simple and rapid tool currently exist for assessing cardiac output in critically ill patients.
The measurement of end-tidal carbon dioxide (EtCO2) used in routine in critically ill patients requiring mechanical ventilation could be an interesting alternative. Indeed, the amount of carbon dioxide (CO2) exhaled depends on the production of CO2 by the body, the pulmonary blood flow (corresponding to cardiac output) and its elimination by alveolar ventilation. In controlled ventilation, ie for constant alveolar ventilation, EtCO2 should therefore depend only on cardiac output. It has been shown in a porcine model that EtCO2 and cardiac output are strongly related under stable respiratory and metabolic conditions. In humans, only the variation of EtCO2 after volume expansion has been studied and EtCO2 seems to reflect changes in cardiac output. Nevertheless, the usefulness of EtCO2 in assessing cardiac output has never been evaluated.
The objective of this study is therefore to determine the relationship between EtCO2 and cardiac output evaluated by the measurement of subaortic VTI in critically ill patients.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| End tidal carbon monoxide | Diagnostic Test |
|
|
| Measure | Description | Time Frame |
|---|---|---|
| Correlation between cardiac output (VTI) and EtCO2 | ITV ≈ (FR x EtCO2)/PaCO2 | between 0 to 3 day after ICU admission |
| Measure | Description | Time Frame |
|---|---|---|
| Increase the sensitivity for detection of low cardiac output by using EtCO2 | Estimate (development population) and validate (validation population) cut-off to detect low cardiac output by using EtCO2 | between 0 to 3 day after ICU admission |
| Correlation between cardiac output (VTI) and portal veinous velocity |
Not provided
Inclusion Criteria:
Exclusion Criteria:
(be increased without correlation to an infectious process (poly-traumatised patients,
Not provided
Not provided
Not provided
All patients > 18 years intubated and ventilated in the control assisted mode with no inspiratory effort referred to the intensive unit.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Intensive care unit, University hospital of Besançon | Recruiting | Besançon | 25000 | France |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 28595621 | Background | Mercado P, Maizel J, Beyls C, Titeca-Beauport D, Joris M, Kontar L, Riviere A, Bonef O, Soupison T, Tribouilloy C, de Cagny B, Slama M. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient. Crit Care. 2017 Jun 9;21(1):136. doi: 10.1186/s13054-017-1737-7. | |
| 28993038 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D004452 | Echocardiography |
| ID | Term |
|---|---|
| D057791 | Cardiac Imaging Techniques |
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
| between 0 to 3 day after ICU admission |
| Comparison between cardiac output (VTI) and femoral veinous velocity | between 0 to 3 day after ICU admission |
| Long B, Koyfman A, Vivirito MA. Capnography in the Emergency Department: A Review of Uses, Waveforms, and Limitations. J Emerg Med. 2017 Dec;53(6):829-842. doi: 10.1016/j.jemermed.2017.08.026. Epub 2017 Oct 7. |
| 3931979 | Background | Weil MH, Bisera J, Trevino RP, Rackow EC. Cardiac output and end-tidal carbon dioxide. Crit Care Med. 1985 Nov;13(11):907-9. doi: 10.1097/00003246-198511000-00011. |
| 22990869 | Background | Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, Guerin L, Richard C, Teboul JL. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med. 2013 Jan;39(1):93-100. doi: 10.1007/s00134-012-2693-y. Epub 2012 Sep 19. |
| D014463 | Ultrasonography |
| D006334 | Heart Function Tests |
| D003935 | Diagnostic Techniques, Cardiovascular |