This study evaluates the application of non-invasive brain stimulation in the treatment of Mild Cognitive Impairment (MCI) in adults aged 55-85. Half of the participants will receive transcranial direct current stimulation (tDCS), while the other half will receive sham (like placebo) stimulation.
The purpose of this study is to investigate whether giving transcranial direct current stimulation (tDCS) treatment using an investigational device called the Soterix tES Device (tDCS device) on the right side of the brain can improve performance on cognitive tests. Investigational means that the tDCS device is not approved by the U.S. Food and Drug Administration (FDA) for the use in this study.
tDCS is a non-invasive way to electrically stimulate the brain. The tDCS device is portable and runs on two 9-volt batteries. Electrodes from the tDCS device carry weak electrical current through the scalp and skull and into the brain. When the direction of the electric current flow is called cathodal, the brain under the site of stimulation reduces its activity.
When tasks are performed, certain parts of the brain are activated. Research studies have shown that younger adults and older adults activate similar parts of the brain when performing the same task (a memory task, for example). However, other researchers found older adults who scored worse on memory tasks, and those with Mild Cognitive Impairment, activated an additional part of the brain so both sides of the brain are activated. Researchers are not sure whether this additional activation is helpful or not. Investigators in this study believe that this extra activation may be contributing to worse performance on tasks.
It may be possible to use tDCS to reduce the brain activity on the extra activation (right) side in older adults, to resemble an activation pattern seen in younger adults (or higher scoring cohort). Using cathodal tDCS to reduce brain activity might help the brain in performing tasks.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Active tDCS | Active Comparator | Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week. |
|
| Sham tDCS | Sham Comparator | Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001 | Device | Transcranial direct current stimulation works by sending constant, low direct current through the electrodes. When these electrodes are placed in the region of interest, the current induces intracerebral current flow. This current flow then either increases or decreases the neuronal excitability in the specific area being stimulated based on which type of stimulation is being used. This change of neuronal excitability leads to alteration of brain function, which can be used in various therapies as well as to provide more information about the functioning of the human brain. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Flanker Inhibitory Control and Attention Test Scores | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Baseline, 1-month post intervention |
| Change in Picture Vocabulary Test Scores | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Baseline, 1 month post intervention |
| Change in List Sorting Working Memory Test Scores | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Baseline, 1 month post intervention |
| Change in Dimensional Change Card Sort Test | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Yonas E Geda, MD, MSc | Mayo Clinic | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mayo Clinic in Arizona | Scottsdale | Arizona | 85259 | United States |
Not provided
| Label | URL |
|---|---|
| Mayo Clinic Clinical Trials | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Active tDCS | Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week. |
| FG001 | Sham tDCS | Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Active tDCS | Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Change in Flanker Inhibitory Control and Attention Test Scores | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Posted | Least Squares Mean | Standard Error | score on a scale | Baseline, 1-month post intervention |
|
A symptom-based questionnaire was used to measure adverse events and was administered at each intervention visit for the 5 consecutive days over a total study duration of 12 months.
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Active tDCS | Active tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The active tDCS intervention include stimulation for 15 minutes at 1mA. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Dr. Yonas Geda | Mayo Clinic | 480-301-6934 | geda.yonas@mayo.edu |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Jul 19, 2017 | Feb 20, 2020 | Prot_SAP_000.pdf |
Not provided
| ID | Term |
|---|---|
| D060825 | Cognitive Dysfunction |
| D003072 | Cognition Disorders |
| ID | Term |
|---|---|
| D019965 | Neurocognitive Disorders |
| D001523 | Mental Disorders |
Not provided
Not provided
| ID | Term |
|---|---|
| D065908 | Transcranial Direct Current Stimulation |
| ID | Term |
|---|---|
| D004599 | Electric Stimulation Therapy |
| D013812 | Therapeutics |
| D003295 | Convulsive Therapy |
| D013000 | Psychiatric Somatic Therapies |
Not provided
Not provided
Randomized 1:1 to active or sham transcranial direct current stimulation (tDCS) intervention
Not provided
Not provided
Double-blind
|
|
| Baseline, 1 month post intervention |
| Change in Pattern Comparison Processing Speed Test Scores | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Baseline, 1 month post intervention |
| Change in Picture Sequence Memory Test v2.1 Score | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Baseline, 1 month post intervention |
| Change in Oral Reading Recognition Test Score | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Baseline, 1 month post intervention |
| BG001 | Sham tDCS | Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week. |
| BG002 | Total | Total of all reporting groups |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Ethnicity (NIH/OMB) | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| OG001 | Sham tDCS | Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week. |
|
|
|
| Primary | Change in Picture Vocabulary Test Scores | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Posted | Least Squares Mean | Standard Error | score on a scale | Baseline, 1 month post intervention |
|
|
|
|
| Primary | Change in List Sorting Working Memory Test Scores | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Posted | Least Squares Mean | Standard Error | score on a scale | Baseline, 1 month post intervention |
|
|
|
|
| Primary | Change in Dimensional Change Card Sort Test | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Posted | Least Squares Mean | Standard Error | score on a scale | Baseline, 1 month post intervention |
|
|
|
|
| Primary | Change in Pattern Comparison Processing Speed Test Scores | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Posted | Least Squares Mean | Standard Error | score on a scale | Baseline, 1 month post intervention |
|
|
|
|
| Primary | Change in Picture Sequence Memory Test v2.1 Score | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Posted | Least Squares Mean | Standard Error | score on a scale | Baseline, 1 month post intervention |
|
|
|
|
| Primary | Change in Oral Reading Recognition Test Score | Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10. | Posted | Least Squares Mean | Standard Error | score on a scale | Baseline, 1 month post intervention |
|
|
|
|
| 0 |
| 8 |
| 0 |
| 8 |
| 0 |
| 8 |
| EG001 | Sham tDCS | Sham tDCS uses the Soterix Medical 1x1 Low Intensity Transcranial Electrical Stimulator (tES) Model 2001. The sham tDCS intervention lasts for 15 minutes. The cathode electrode will be placed over the right dorsolateral prefrontal cortex with reference electrode (anode) over the left dorsolateral prefrontal cortex. Both electrodes are covered by saline-soaked sponges that are held against the scalp by a pair of large, adjustable head straps. Treatment sessions will last for 15 minutes. 5 consecutive treatment sessions will be completed within 1 week. | 0 | 8 | 0 | 8 | 0 | 8 |
Not provided
Not provided
Not provided
| D004191 | Behavioral Disciplines and Activities |
| D004597 | Electroshock |
| D011580 | Psychological Techniques |
| Superiority |
| Wilcoxon (Mann-Whitney) | 0.2500 | Superiority |
| Superiority |
| Wilcoxon (Mann-Whitney) | 0.7500 | Superiority |
| Superiority |
| Wilcoxon (Mann-Whitney) | 0.7188 | Superiority |
| Superiority |
| Wilcoxon (Mann-Whitney) | 0.0156 | Superiority |
| Superiority |
| Wilcoxon (Mann-Whitney) | 0.0938 | Superiority |
| Superiority |
| Wilcoxon (Mann-Whitney) | 1.0000 | Superiority |