There are patient related risk factors for PPI that can be identified and assessed in retrospective pooling of 1000+ TAVI patient datasets.
Retrospective pooling of 6 datasets already available at participating centres (4 sites in Germany, 1 in Zwolle / The Netherlands, 1 in Linköping / Sweden).
Additional assessment of calcifications using a CT data core lab. Statistical analysis of the obtained dataset with respect to the objectives of the registry.
Permanent pacemaker implantation is a widely recognized clinical event associated with TAVI becoming evident within a few days after the procedure.
While a number of registries have documented the rates of PPI with different valves, much less evidence has been provided for 1) patient based characteristics (e.g. RBBB etc.) affecting the likelihood of PPI and for 2) procedural variables (e.g. implantation depth, valve size etc.) that should be considered to perform an as safe and minimal invasive procedure as possible.
Prior research To date there are 7 published reports on pacemaker rates and predictors associated with the use of the Edwards SAPIEN 3 THV (see Table). These studies suggest that the need for pacemaker implantation in single centers ranges between 14.4 and 20.4% derived from patient numbers between 131 and 335. These analyses resulted in the identification of pre-existing conduction disturbance / aortic valve calcification as patient related and implantation depth /oversizing as procedure related variables associated with Edwards SAPIEN 3 THV TAVI. Furthermore a scoring algorithm for patient related factors has been proposed from a dataset of 240 patients to predict the likelihood of PPI after THV .
Limitations of prior research Current evidence though is limited by patient numbers versus event rates (with a max. of 62 PPI considered in any of the available datasets) resulting in a limited power in multivariable analyses, the single center design of these ventures, the lack of a consistent definition of variables potentially associated and the unexplained differences in the number and type of variables identified.
Aims For this reason the investigators consider it necessary to 1) to retrospectively pool data from all of these 7 datasets to arrive at a more comprehensive picture of patient related variables (retrospective part I), to 2) assess procedural variables in a prospective multicenter registry (prospective part II) and 3) to potentially validate the identified variables in a future prospective cohort.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients with aortic stenosis | Patients receiving Edwards SAPIEN 3 Transcatheter aortic valve implantation |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| transcatheter valve implantation | Procedure | aortic transcatheter valve implantation using Edwards SAPIEN 3 valve |
|
| Measure | Description | Time Frame |
|---|---|---|
| occurence of PPI after TAVI | need for permanent pacemaker implantation after TAVI | 30 days |
| Measure | Description | Time Frame |
|---|---|---|
| Timing of PPI | Time interval after TAVI until PPI in days | 30 days |
| Indications for PPI | possible reasons to implant a PP:
|
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Patients that already underwent transfemoral transcatheter valve implantation with the SAPIEN 3 valve
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Tobias Geisler, Prof. | University Clinic Tübingen, Tübingen, Germany - Department of Internal Medicine III | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Clinic Tübingen, Department of Internal Medicine III | Tübingen | Baden-Wurttemberg | 72076 | Germany | ||
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 32591894 | Result | Droppa M, Rudolph TK, Baan J, Nielsen NE, Baumgartner H, Vendrik J, Froehlich M, Borst O, Wohrle J, Gawaz M, Potratz P, Hack LP, Mauri V, Baranowski J, Bramlage P, Kurucova J, Thoenes M, Rottbauer W, Geisler T. Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis. Heart Vessels. 2020 Dec;35(12):1735-1745. doi: 10.1007/s00380-020-01653-6. Epub 2020 Jun 26. | |
| 36750275 |
Not provided
Not provided
no IPD will be made available
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001024 | Aortic Valve Stenosis |
| D054537 | Atrioventricular Block |
| D002037 | Bundle-Branch Block |
| C562942 | Aortic Valve, Calcification of |
| ID | Term |
|---|---|
| D000082862 | Aortic Valve Disease |
| D006349 | Heart Valve Diseases |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D065467 | Transcatheter Aortic Valve Replacement |
| ID | Term |
|---|---|
| D019918 | Heart Valve Prosthesis Implantation |
| D006348 | Cardiac Surgical Procedures |
| D013504 | Cardiovascular Surgical Procedures |
| D013514 | Surgical Procedures, Operative |
Not provided
Not provided
Not provided
Not provided
Not provided
| 30 days |
| University Clinic Ulm, Department of Internal Medicine II |
| Ulm |
| Baden-Wurttemberg |
| 89073 |
| Germany |
| Herzzentrum, Universität Köln | Cologne | North Rhine-Westphalia | 50937 | Germany |
| Universitätsklinikum Münster, Klinik und Poliklinik für Erwachsene mit angeborenen und erworbenen Herzfehlern | Münster | North Rhine-Westphalia | 48149 | Germany |
| Derived |
| Rudolph T, Droppa M, Baan J, Nielsen NE, Baranowski J, Hachaturyan V, Kurucova J, Hack L, Bramlage P, Geisler T. Modifiable risk factors for permanent pacemaker after transcatheter aortic valve implantation: CONDUCT registry. Open Heart. 2023 Feb;10(1):e002191. doi: 10.1136/openhrt-2022-002191. |
| D014694 |
| Ventricular Outflow Obstruction |
| D006327 | Heart Block |
| D001145 | Arrhythmias, Cardiac |
| D000075224 | Cardiac Conduction System Disease |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D019919 | Prosthesis Implantation |
| D019616 | Thoracic Surgical Procedures |