The purpose of this study is the verification of Cloud-DX Vitalitiâ„¢ Continuous Automated Non-Invasive Blood Pressure Monitor for Clinical Use and Self Measurement according to standards laid out by IEEE Std 1708 and AAMI-ISO 81060-2.
Several automated vital sign measurement systems have been developed recently; however, non-invasive continuous blood pressure monitoring continues to be a major limitation. To circumvent the limitations of current systems of interval hemodynamic measurement and increasing demands on health care providers, a non-invasive automated continuous vital sign monitor that can integrate into hospital early warning systems and warn health care providers of deteriorating vital sign parameters would be of significant value and a major advance for current hospital monitoring systems.
Cloud-DX Vitalitiâ„¢ is a new low profile automated vital sign monitor, which includes a continuous non-invasive blood pressure measurement system. Additional parameters are also measured. Paired with companion software from cloud based computing, Vitalitiâ„¢ features a user friendly interface, onboard radios for communication with smartphones/tablets/personal computers, and several sensors.
Cloud-DX Vitalitiâ„¢ has undergone preliminary testing and is now ready for verification to achieve compliance with AAMI/ISO and IEEE standards of medical grade device. At the Hamilton General Hospital (HGH), Cardiac Surgical Intensive Care Unit (CICU) and Vascular Surgical Step Down Units, arterial catheters are standard of care and performed on most patients for variable periods of post-operative recovery. Within this setting, the IEEE Std 1708 and AAMI-ISO 81060-2 would be fully met. Furthermore, the cardiovascular surgical caseloads at HGH would provide sufficient test subjects to validate VitalitiTM in a timely fashion.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Vitaliti | Other | The subject's blood pressure will be simultaneously determined and recorded using the invasive arterial line blood pressure reading and the test Vitaliti device readings. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Vitaliti | Device | Measurements recorded by the Vitaliti device will be compared to the recordings from the arterial catheter. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Blood pressure | Determining the accuracy of non-invasive blood pressure measurement compared to invasive blood pressure. A detailed analysis will be conducted on the invasive blood pressure to verify accuracy as defined in the ISO 81060-2 Standard. | 30 minutes |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael McGillion, RN, PhD | School of Nursing, Faculty of Health Sciences, McMaster University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hamilton General Hospital | Hamilton | Ontario | L8L 2X2 | Canada |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 34876396 | Derived | McGillion MH, Dvirnik N, Yang S, Belley-Cote E, Lamy A, Whitlock R, Marcucci M, Borges FK, Duceppe E, Ouellette C, Bird M, Carroll SL, Conen D, Tarride JE, Harsha P, Scott T, Good A, Gregus K, Sanchez K, Benoit P, Owen J, Harvey V, Peter E, Petch J, Vincent J, Graham M, Devereaux PJ. Continuous Noninvasive Remote Automated Blood Pressure Monitoring With Novel Wearable Technology: A Preliminary Validation Study. JMIR Mhealth Uhealth. 2022 Feb 28;10(2):e24916. doi: 10.2196/24916. |
Not provided
Not provided
The data which will be collected is only valid for the verification of this particular device.
Not provided
Not provided
Not provided
Not provided
Not provided
Vitaliti Continuous Vital Sign Monitoring Device - Version 2.0