This study evaluates SPECT image data acquired from Spectrum Dynamics' multi-purpose CZT SPECT-CT camera. All subjects will undergo routine clinical Anger SPECT imaging and an additional SPECT acquisition on the CZT SPECT camera. Additionally some subjects will undergo CT on the CZT SPECT-CT camera. The quality of images from each device will be compared.
The Spectrum Dynamics Multi-purpose CZT SPECT camera is a whole body SPECT (single photon emission computed tomography) scanner which utilises solid-state cadmium zinc telluride (CZT) detectors to visualise injected, or otherwise introduced, radioactivity in the human body. The CZT SPECT camera detects the location and distribution of gamma-emitting radionuclides in the body and produces 3 dimensional cross-sectional images through computed reconstruction of the data for the purpose of determining various metabolic and physiologic functions in the human body. In comparison to conventional sodium iodide (NaI) gamma camera (or Anger camera) technology, solid state CZT technology offers improved energy, spatial and temporal resolution, and higher count rates. Improvements in energy resolution and sensitivity thus enable the potential capability for enhanced quantification, simultaneous dual isotope imaging and dynamic imaging acquisition. The camera system also incorporates a multi-slice CT gantry and acquired SPECT and CT images can be combined to improve image reconstruction by allowing fusion of CT and SPECT image data for anatomic localisation referencing and CT attenuation correction of the SPECT image data.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| CZT SPECT | Experimental | CZT SPECT imaging with/without the addition of CT on the Spectrum Dynamics camera |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| CZT SPECT imaging | Device | Acquisition of SPECT (single photon emission computed tomography) imaging utilising a camera system with solid-state cadmium zinc telluride (CZT) detectors to visualise injected, or otherwise introduced, radioactivity in the human body. |
| Measure | Description | Time Frame |
|---|---|---|
| CZT SPECT Image Acquisition | Technical adequacy of acquired CZT SPECT images for demonstrating the location and distribution of gamma ray radionuclides within the body | 1 day |
| CZT SPECT-CT Image Acquisition | Technical adequacy of acquired CZT SPECT-CT images for demonstrating the location and distribution of gamma ray radionuclides within the body | 1 day |
| Measure | Description | Time Frame |
|---|---|---|
| CZT SPECT Image Quality | Quality of acquired SPECT images from the CZT SPECT camera | 1 day |
| Comparative Quality of CZT and Anger SPECT Images | Quality of acquired CZT SPECT images in comparison to the quality of images obtained from a conventional Anger gamma camera |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Denis Agostini, MD.PhD | University Hospital, Caen | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| CHU de Caen | Caen | Normandy | 14033 | France |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003704 | Dementia |
| D010300 | Parkinson Disease |
| D006976 | Hypertension, Pulmonary |
| D006331 | Heart Diseases |
| D001847 | Bone Diseases |
| D050723 | Fractures, Bone |
| D007674 | Kidney Diseases |
| D011655 | Pulmonary Embolism |
| ID | Term |
|---|---|
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D019965 | Neurocognitive Disorders |
Not provided
Not provided
All subjects undergo baseline clinically referred routine nuclear scintigraphy imaging and sequential imaging on the CZT SPECT investigational device following a single dose of radiopharmaceutical. Some subjects will additionally undergo CT on the CZT SPECT-CT investigational device.
Not provided
Not provided
Not provided
Not provided
| 1 day |
| Safety of the CZT SPECT Camera | Incidence of device related Adverse Events occurring during clinical use of the Spectrum Dynamics Multi-purpose CZT SPECT camera | Through study completion; anticipated to be 24 months |
| Safety of the CZT SPECT Camera During Imaging Procedures | Incidence of peri-procedural Adverse Events | 1 day |
| CZT SPECT-CT Image Quality | Quality of acquired SPECT-CT images from the CZT SPECT-CT camera | 1 day |
| Comparative Quality of CZT SPECT-CT and Anger SPECT Images | Quality of acquired CZT SPECT-CT images in comparison to the quality of images obtained from a conventional Anger gamma camera | 1 day |
| Safety of the CZT SPECT-CT Camera | Incidence of device related Adverse Events occurring during clinical use of the Spectrum Dynamics Multi-purpose CZT SPECT-CT camera | Through study completion; anticipated to be 24 months |
| Safety of the CZT SPECT-CT Camera During Imaging Procedures | Incidence of peri-procedural Adverse Events | 1 day |
| D001523 | Mental Disorders |
| D020734 | Parkinsonian Disorders |
| D001480 | Basal Ganglia Diseases |
| D009069 | Movement Disorders |
| D000080874 | Synucleinopathies |
| D019636 | Neurodegenerative Diseases |
| D008171 | Lung Diseases |
| D012140 | Respiratory Tract Diseases |
| D006973 | Hypertension |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D009140 | Musculoskeletal Diseases |
| D014947 | Wounds and Injuries |
| D014570 | Urologic Diseases |
| D052776 | Female Urogenital Diseases |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
| D000091642 | Urogenital Diseases |
| D052801 | Male Urogenital Diseases |
| D004617 | Embolism |