The study is designed to repeat an initial training set study conducted at Johns Hopkins Medical Center, comparing a new investigational device, Indicor, a non-invasive tool for estimating left ventricular end diastolic pressure (LVEDP), to the gold standard, invasively measured LVEDP via direct measurement via left heart catheterization. The study is divided into an initial training set, followed by the validation set which is designed to support an FDA 510(k) submission and validate the final algorithm. Patients will be enrolled who are scheduled to undergo a cardiac catheterization and will be asked to perform three tests with the Indicor.
Patients who are scheduled to undergo a left heart cardiac catheterization for direct measure of left ventricular end diastolic pressure (LVEDP) as part of routine care will be asked to participate. Investigators will take non-invasive measures of LVEDP using the Indicor device, repeated at three time points before and after the catheterization procedure. The Indicor indirectly measures LVEDP by calculating a value from finger photoplethysmography (PPG) waveforms that will be recorded while the patient performs a Valsalva maneuver.
Participants baseline characteristics will be gathered from the electronic medical record, including history of coronary artery disease, heart failure, hypertension, diabetes, or lung disease; list of blood pressure medications; serum markers of kidney function; and echocardiogram measurements including ejection fraction. These parameters will be used to assess relevance to the calculation of LVEDP by Indicor.
The first Indicor measure will be conducted before the catheterization procedure. PPG probes will be attached to participants' first or second finger. Participants will be asked to strain as if having a bowel movement (Valsalva maneuver) for 10 seconds. Participants will blow into a pressure transducer that measures and displays the pressure of their effort. The Indicor device will acquire 3 successful efforts.
During the cardiac catheterization, while the pressure transducer used by the clinical team to measure LVEDP is in the aorta, the Valsalva testing will be repeated. The device will again acquire 3 successful efforts. This will allow investigators to determine how well the amplitude changes of the PPG signal during Valsalva maneuver reflect the amplitude changes of central arterial pressure during the Valsalva maneuver. According to experienced catheterization cardiologists, this set of tests will not add significant risk to the procedure. This second set of tests may not be performed in all participants.
Immediately after the cardiac catheterization, while the patient is still on the catheterization table, the Valsalva testing will be repeated. The device will again acquire 3 successful efforts.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| LeftHeartCath | Patients scheduled for LV catheterization for direct measurement of LVEDP |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Indicor | Diagnostic Test | Calculation of LVEDP via analysis of PPG waveform with Valsalva |
|
| Measure | Description | Time Frame |
|---|---|---|
| C-LVEDP | Specificity of Calculated LVEDP (C-LVEDP) in identifying invasively Measured LVEDP (M-LVEDP) > 20 mmHg | During patients scheduled left heart cardiac catheterization |
Not provided
Not provided
Inclusion Criteria:
-Adult patients scheduled to undergo a left-heart catheterization that will include the measurement of left ventricular end-diastolic pressure (LVEDP)
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients scheduled to undergo cardiac catheterization as part of their routine care and clinically indicated
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Harry Silber, MD, PhD | Johns Hopkins Medical Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Christiana Care | Newark | Delaware | 19713 | United States | ||
| Deborah Heart and Lung Center |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 28754567 | Background | Gilotra NA, Tedford RJ, Wittstein IS, Yenokyan G, Sharma K, Russell SD, Silber HA. Usefulness of Pulse Amplitude Changes During the Valsalva Maneuver Measured Using Finger Photoplethysmography to Identify Elevated Pulmonary Capillary Wedge Pressure in Patients With Heart Failure. Am J Cardiol. 2017 Sep 15;120(6):966-972. doi: 10.1016/j.amjcard.2017.06.029. Epub 2017 Jun 28. | |
| 28185634 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| Browns Mills |
| New Jersey |
| 08015 |
| United States |
| Stony Brook Medicine | Stony Brook | New York | 11794 | United States |
| Lancaster General Health | Lancaster | Pennsylvania | 17603 | United States |
| Background |
| Galiatsatos P, Win TT, Monti J, Johnston PV, Herzog W, Trost JC, Hwang CW, Fridman GY, Wang NY, Silber HA. Usefulness of a Noninvasive Device to Identify Elevated Left Ventricular Filling Pressure Using Finger Photoplethysmography During a Valsalva Maneuver. Am J Cardiol. 2017 Apr 1;119(7):1053-1060. doi: 10.1016/j.amjcard.2016.11.063. Epub 2017 Jan 5. |
| 22389389 | Background | Silber HA, Trost JC, Johnston PV, Maughan WL, Wang NY, Kasper EK, Aversano TR, Bush DE. Finger photoplethysmography during the Valsalva maneuver reflects left ventricular filling pressure. Am J Physiol Heart Circ Physiol. 2012 May 15;302(10):H2043-7. doi: 10.1152/ajpheart.00609.2011. Epub 2012 Mar 2. |
| 12374516 | Background | Sharma GV, Woods PA, Lambrew CT, Berg CM, Pietro DA, Rocco TP, Welt FW, Sacchetti P, McIntyre KM. Evaluation of a noninvasive system for determining left ventricular filling pressure. Arch Intern Med. 2002 Oct 14;162(18):2084-8. doi: 10.1001/archinte.162.18.2084. |
| 16596832 | Background | Gillard C, Henuzet C, Lallemand J, Moscariello A, Guillaume M, Van Meerhaeghe A. Operating characteristics of the Finapress system to predict elevated left ventricular filling pressure. Clin Cardiol. 2006 Mar;29(3):107-11. doi: 10.1002/clc.4960290305. |
| 22840672 | Background | Zema MJ. Bedside assessment of cardiac hemodynamics: role of the simple Valsalva maneuver. Am J Med. 2012 Aug;125(8):e13; author reply e15-6. doi: 10.1016/j.amjmed.2011.12.020. No abstract available. |
| 16443410 | Background | Felker GM, Cuculich PS, Gheorghiade M. The Valsalva maneuver: a bedside "biomarker" for heart failure. Am J Med. 2006 Feb;119(2):117-22. doi: 10.1016/j.amjmed.2005.06.059. |
| 2913385 | Background | Stevenson LW, Perloff JK. The limited reliability of physical signs for estimating hemodynamics in chronic heart failure. JAMA. 1989 Feb 10;261(6):884-8. |