This study aims to assess the efficacy of three-dimensional magnetic resonance (MR) compared to three-dimensional computed tomography (CT) imaging. This proposed study is a prospective, unrandomized, single-blinded, self-controlled, and single-armed diagnostic radiological evaluation study.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 3D MR and 3D CT Imaging | Other | All shoulder arthroplasty candidates with glenohumeral osteoarthritis will be receiving both 3D computed tomography (CT) and 3D non-contrast magnetic resonance (MR) imaging. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 3-dimensional (3D) magnetic resonance (MR) imaging | Diagnostic Test | MRI is performed using 3T scanners with a dedicated 16-channel shoulder array coils. The MRI sequences include 3-mm slice thickness and 0.5-mm gap width with a field of view of 14 or 15 cm. There were 6 diagnostic sequences with axial, coronal, and sagittal proton density weighting as well as coronal T2 with frequency selective fat suppression and sagittal T1 images. |
| Measure | Description | Time Frame |
|---|---|---|
| Glenoid Version | All scans from 3D CT and 3D MR imaging were reviewed carefully for the presence of any morphological changes. For the determination of glenoid version, a line was drawn between the anterior and posterior margins of the glenoid. The transverse axis of the scapula was determined by a line drawn from the midpoint of the genoid fossa to the medial end of the image of the scapula; a line drawn perpendicular to this was defined as a line of neutral version. The angle between the line of neutral version and the line connecting the anterior and posterior margins of the glenoid was measured and recorded as the Glenoid Version. | 3 Months |
| Glenoid Inclination | The 3D MRI glenoid inclination is measured by the two observers with the same method used for CT 3D glenoid inclination measurement following generating a new 2D axial MR images form the 3D MRI model using the three-point method. A line on the supraspinatus fossa and 3 points are drawn: Point S represents the inferior border of the glenoid, point R represents the intersection of the supraspinatus fossa line with the glenoid surface, and point A represents the vertex of the right triangle created by the line of the supraspinatus fossa and a perpendicular line passing through point S; this line (RS) is the hypotenuse of the right triangle. The inclination corresponds to the area in which the glenoid component of RSA is implanted. | 3 Months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Joseph D Zuckerman, MD | NYU Langone Health | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| New York University School of Medicine | New York | New York | 10016 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Shoulder Arthroplasty (SA) | 3D computed tomography (CT) and 3D non-contrast magnetic resonance (MR) 3-dimensional (3D) magnetic resonance (MR): MRI is performed using 3T scanners with a dedicated 16-channel shoulder array coils. The MRI sequences include 3-mm slice thickness and 0.5-mm gap width with a field of view of 14 or 15 cm. There were 6 diagnostic sequences with axial, coronal, and sagittal proton density weighting as well as coronal T2 with frequency selective fat suppression and sagittal T1 images. 3D computed tomography (CT) imaging: The CT protocol consists of 3-mm axial images of the glenoid reconstructed into 1-mm sagittal and coronal 2D reconstructions using the following parameters: 120 kV, 280 mA, and pitch of 0.9. The CT data were also used to produce a 3D reconstruction of each glenoid. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Shoulder Arthroplasty (SA) | 3D computed tomography (CT) and 3D non-contrast magnetic resonance (MR) 3-dimensional (3D) magnetic resonance (MR): MRI is performed using 3T scanners with a dedicated 16-channel shoulder array coils. The MRI sequences include 3-mm slice thickness and 0.5-mm gap width with a field of view of 14 or 15 cm. There were 6 diagnostic sequences with axial, coronal, and sagittal proton density weighting as well as coronal T2 with frequency selective fat suppression and sagittal T1 images. 3D computed tomography (CT) imaging: The CT protocol consists of 3-mm axial images of the glenoid reconstructed into 1-mm sagittal and coronal 2D reconstructions using the following parameters: 120 kV, 280 mA, and pitch of 0.9. The CT data were also used to produce a 3D reconstruction of each glenoid. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Median |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Glenoid Version | All scans from 3D CT and 3D MR imaging were reviewed carefully for the presence of any morphological changes. For the determination of glenoid version, a line was drawn between the anterior and posterior margins of the glenoid. The transverse axis of the scapula was determined by a line drawn from the midpoint of the genoid fossa to the medial end of the image of the scapula; a line drawn perpendicular to this was defined as a line of neutral version. The angle between the line of neutral version and the line connecting the anterior and posterior margins of the glenoid was measured and recorded as the Glenoid Version. | Posted | Mean | Standard Deviation | degrees | 3 Months |
|
6 months
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Shoulder Arthroplasty (SA) | 3D computed tomography (CT) and 3D non-contrast magnetic resonance (MR) 3-dimensional (3D) magnetic resonance (MR): MRI is performed using 3T scanners with a dedicated 16-channel shoulder array coils. The MRI sequences include 3-mm slice thickness and 0.5-mm gap width with a field of view of 14 or 15 cm. There were 6 diagnostic sequences with axial, coronal, and sagittal proton density weighting as well as coronal T2 with frequency selective fat suppression and sagittal T1 images. 3D computed tomography (CT) imaging: The CT protocol consists of 3-mm axial images of the glenoid reconstructed into 1-mm sagittal and coronal 2D reconstructions using the following parameters: 120 kV, 280 mA, and pitch of 0.9. The CT data were also used to produce a 3D reconstruction of each glenoid. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Joseph Zuckerman, MD | NYU Langone Health | 212-598-6674 | Joseph.Zuckerman@nyulangone.org |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Oct 11, 2017 | Apr 3, 2020 | Prot_SAP_000.pdf |
Not provided
| ID | Term |
|---|---|
| D001168 | Arthritis |
| ID | Term |
|---|---|
| D007592 | Joint Diseases |
| D009140 | Musculoskeletal Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D008279 | Magnetic Resonance Imaging |
| D003952 | Diagnostic Imaging |
| ID | Term |
|---|---|
| D014054 | Tomography |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| 3D computed tomography (CT) imaging | Diagnostic Test | The CT protocol consists of 3-mm axial images of the glenoid reconstructed into 1-mm sagittal and coronal 2D reconstructions using the following parameters: 120 kV, 280 mA, and pitch of 0.9. The CT data were also used to produce a 3D reconstruction of each glenoid. |
|
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race and Ethnicity Not Collected | Race and Ethnicity were not collected from any participant. | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
|
|
| Primary | Glenoid Inclination | The 3D MRI glenoid inclination is measured by the two observers with the same method used for CT 3D glenoid inclination measurement following generating a new 2D axial MR images form the 3D MRI model using the three-point method. A line on the supraspinatus fossa and 3 points are drawn: Point S represents the inferior border of the glenoid, point R represents the intersection of the supraspinatus fossa line with the glenoid surface, and point A represents the vertex of the right triangle created by the line of the supraspinatus fossa and a perpendicular line passing through point S; this line (RS) is the hypotenuse of the right triangle. The inclination corresponds to the area in which the glenoid component of RSA is implanted. | Posted | Mean | Standard Deviation | degrees | 3 Months |
|
|
|
| 0 |
| 29 |
| 0 |
| 29 |
| 0 |
| 29 |