Severe Trauma Brain Injury (TBIs) is a public health problem and monitoring of Intracranial Pressure (ICP) is a determinant key of it prognosis. Within the noninvasive methods to estimate the ICP, the measurement of intraocular pressure has been proposed because of its biological plausibility (proximity of the eye to the encephalic contend).
Objective. Correlate intraocular pressure with ICP in children with TBIs and obtain their utility values.
Severe Trauma Brain Injury (TBIs) is a public health problem and monitoring of Intracranial Pressure (ICP) is a determinant key of it prognosis. Within the noninvasive methods to estimate the ICP, the measurement of intraocular pressure has been proposed because of its biological plausibility (proximity of the eye to the encephalic contend).
Objective. Correlate intraocular pressure with ICP in children with TBIs and obtain their utility values.
Material and methods. Correlation and diagnostic test design study. Inclusion criteria: children with TBIs admitted to the emergency room and indication of catheter for ICP measurement.
Exclusion criteria: injury or ophthalmic disease, glaucoma, encephalic death. Intraocular pressure was measured with electronic tonometer in both eyes prior to placement of the catheter for ICP measurement.
Correlation was estimated with Spearman's Rho. The utility values of the diagnostic test were obtained from an Receiver Operating Characteristic curve.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| With intraocular pressure high | Intracranial pressure equal or more than 20 mmHg |
| |
| Without intraocular pressure high | Intracranial pressure smaller than 20 mmHg |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| with intraocular pressure high | Diagnostic Test | Measurement of intraocular pressure The measurement will be made with a electronic minimum contact tonometer for measuring intraocular pressure immediately before the placement of the invasive catheter for measurement of intracranial pressure. |
| Measure | Description | Time Frame |
|---|---|---|
| Intraocular pressure smaller than 20 mmHg | Abscence of increased intraocular pressure (smaller than 20 mmHg) without intracranial pressure smaller than 20 mmHg. | Immediately |
| Measure | Description | Time Frame |
|---|---|---|
| Intraocular pressure equal or more than 20 mmHg | Intraocular pressure equal or more than 20 mmHg with Intracranial pressure equal or more than 20 mmHg | Immediately |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Children of 2 at 15 years old with severe trauma brain injury (Coma Glasgow Scale smaller than 9 points), in pediatric emergency room, with indication by the neurosurgeon to place a invasive catheter for intracranial pressure measurement.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Karla Isis I Aviles-Martinez, PhD | Contact | 39424400 | 48052 | draisispediatra@yahoo.com.mx |
| Adriana López-EnrÃquez, MD | Contact | 39424400 | 48051 | aleurg2@hotmail.com |
| Name | Affiliation | Role |
|---|---|---|
| Karla Isis I Aviles Martinez, PhD | Hospital Civil Fray Antonio Alcalde | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital Civil Fray Antonio Alcalde | Recruiting | Guadalajara | Jalisco | 44280 | Mexico |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D019586 | Intracranial Hypertension |
| D000070642 | Brain Injuries, Traumatic |
| ID | Term |
|---|---|
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D001930 | Brain Injuries |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| without intraocular pressure high | Diagnostic Test | Measurement of intraocular pressure The measurement will be made with a electronic minimum contact tonometer for measuring intraocular pressure immediately before the placement of the invasive catheter for measurement of intracranial pressure. |
|
| D006259 |
| Craniocerebral Trauma |
| D020196 | Trauma, Nervous System |
| D014947 | Wounds and Injuries |