Not provided
Not provided
Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| HM20011159 | Other Identifier | VCU IRB |
Not provided
Not provided
Not provided
Unable to find any suitable patients to enroll
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Daxor Corporation | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Burn surgery is associated with significant reductions in hematocrit. However, it is unclear whether these reductions are the result of hemodilution from non-red cell containing intraoperative transfusions or from loss of red blood cells. The investigators will be using the Daxor Blood Volume Analyzer (BVA-100), an FDA approved instrument that can measure total blood volume, plasma volume, and RBC volume using the indicator dilution technique. By comparing pre-operative measurements of blood volume, plasma volume, and RBC volume to that of post-operative measurements after burn surgery, the investigators can determine the primary cause of the reduction in hematocrit associated with burn surgery. The investigators hypothesize that these reductions in hematocrit are primarily the result of hemodilution rather than blood loss and that there will be a statistically significant difference in measured plasma volume from the pre-operative group to the post-operative group.
Burn surgery is associated with significant changes (reductions) in hematocrit. However, it is unclear whether these reductions are the result of hemodilution from non-red cell containing intraoperative transfusions or from loss of red blood cells. The investigators will be using the Daxor Blood Volume Analyzer (BVA-100), an FDA approved instrument that can measure total blood volume, plasma volume, and RBC volume using the indicator dilution technique. With this technique, a tracer substance (I-131 albumin) is mixed with an unknown volume. An identical amount of the tracer is mixed into a solution with a known volume. By comparing the concentration of the indicator between the known and unknown volumes, the investigators can determine the volume of the unknown volume (or in this case, the blood volume).
The investigators will be measuring the change in blood volume, plasma volume, and RBC volume from the pre-operative to the post-operative state after completion of burn surgery. We hypothesize that these reductions in hematocrit are primarily the result of hemodilution rather than blood loss and that there will be a statistically significant change in measured plasma volume from the pre-operative to the post-operative measurements.
Average plasma volume for male and female patients is 2950ml SD=590 ml. To detect a 10% increase in plasma volume from hemodilution with a power 0.80 and alpha error 0.05, a one tailed normal distribution t-test determines a sample size fifty. To account for a 10% data loss (technical difficulty, patient withdraw) a sample size of fifty-five would be required.
Fifty-five consecutive adult patients (18 years or older) having burn surgery will be enrolled. Patients with recognized coagulopathy will be excluded. The outcome variables included blood volume (BV, ml), plasma volume (PV, ml) and red blood cell volume (RBCV, ml). All three outcome variables will be measured at two time points; pre-surgery and post-surgery. The pre-surgery measurement will be collected precisely after induction of general anesthesia but prior to surgery start. The post-surgery measurement will be taken immediately after the operation and after all intraoperative red blood cell transfusions are complete. For those patients receiving blood transfusions in the operating room prior to all data collection points, the transfused RBC volume will be recorded and subtracted from the RBCV measured after the transfusion. Transfused RBCV will take into account Hct of 60% for pRBCs. Additional baseline information, including age (year), sex (male, female), weight (kg), and surgery type, will be collected. For the tracer dilution method, the following blood samples will be collected: a baseline (no radiation sample), a first sample 12 minutes after injection (after complete mixing in the blood volume) and additional samples every 6 minutes for at least three successive timed sample points. These multiple timed sample points produce a logarithmic curve of radiation over time, as only a small fraction of albumin leaves the blood volume into the interstitial space. The investigators will compare the pre-operative and post-operative blood volume, RBC volume, and plasma volume measurements to determine if the decrease in hematocrit associated with burn surgery is truly due to hemodilution or loss of RBC volume.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Pre-operative cohort | This cohort will have their total blood volume, RBC volume, and plasma volumes measured using the Daxor BVA-100 prior to any surgical intervention |
| |
| Post-operative cohort | This cohort will consist of the same study participants in the pre-operative cohort. The only difference is that this cohort will have their total blood volume, RBC volume, and plasma volumes measured using the Daxor BVA-100 AFTER burn surgery. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Burn surgery | Procedure | Burn surgery including wound debridement, skin grafting |
| |
| Measure | Description | Time Frame |
|---|---|---|
| Change in measured plasma volume | Measured plasma volume using Daxor BVA-100 | Pre-operative period after intubation, but before surgery start and post-operative period after surgery stop and after all intraoperative blood transfusions are complete |
| Change in measured RBC volume | Measured RBC volume using Daxor BVA-100 | Pre-operative period after intubation, but before surgery start and post-operative period after surgery stop and after all intraoperative blood transfusions are complete |
| Change in measured total blood volume | Measured total blood volume using Daxor BVA-100 | Pre-operative period after intubation, but before surgery start and post-operative period after surgery stop and after all intraoperative blood transfusions are complete |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
18-70 year old male or non-pregnant females who have sustained deep partial thickness to full thickness thermal burns between 10-50% TBSA who are undergoing burn surgery
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mark Nelson, MD | VCU Medical Center | Principal Investigator |
| Michael Feldman, MD | VCU Medical Center | Principal Investigator |
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 16414197 | Background | Ong YS, Samuel M, Song C. Meta-analysis of early excision of burns. Burns. 2006 Mar;32(2):145-50. doi: 10.1016/j.burns.2005.09.005. Epub 2006 Jan 18. | |
| 8471147 | Background | Budny PG, Regan PJ, Roberts AH. The estimation of blood loss during burns surgery. Burns. 1993 Apr;19(2):134-7. doi: 10.1016/0305-4179(93)90036-8. |
Not provided
Not provided
There is no plan to make individual participant data available to other researchers outside of the investigators listed in this study group.
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D016063 | Blood Loss, Surgical |
| D002056 | Burns |
| ID | Term |
|---|---|
| D006470 | Hemorrhage |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D007431 | Intraoperative Complications |
Not provided
Not provided
| ID | Term |
|---|---|
| D010953 | Plasma Volume |
| ID | Term |
|---|---|
| D001810 | Blood Volume |
| D001790 | Blood Physiological Phenomena |
| D002943 | Circulatory and Respiratory Physiological Phenomena |
| D006439 | Hemodynamics |
Not provided
Not provided
Not provided
Not provided
Not provided
Venous blood samples drawn via venipuncture
| Measurement of RBC volume, plasma volume, and total blood volume using Daxor BVA-100 |
| Diagnostic Test |
Measurement of RBC volume, plasma volume, and total blood volume using Daxor BVA-100 |
|
| 11220251 | Background | Meiser A, Casagranda O, Skipka G, Laubenthal H. [Quantification of blood loss. How precise is visual estimation and what does its accuracy depend on?]. Anaesthesist. 2001 Jan;50(1):13-20. doi: 10.1007/s001010050957. German. |
| 15415456 | Background | CRISPELL KR, PORTER B, NIESET RT. Studies of plasma volume using human serum albumin tagged with radioactive iodine. J Clin Invest. 1950 May;29(5):513-6. doi: 10.1172/JCI102288. No abstract available. |
| 17496003 | Background | Manzone TA, Dam HQ, Soltis D, Sagar VV. Blood volume analysis: a new technique and new clinical interest reinvigorate a classic study. J Nucl Med Technol. 2007 Jun;35(2):55-63; quiz 77, 79. doi: 10.2967/jnmt.106.035972. Epub 2007 May 11. |
| D014947 | Wounds and Injuries |
| D002320 | Cardiovascular Physiological Phenomena |