Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| National University of Singapore | OTHER |
Not provided
Not provided
Not provided
Not provided
The study is to investigate the effect of a soft robotic glove approach providing continuous passive motion of fingers (flexion and extension) on degenerative arthritis patients. The approach may help reduce pain, maintain mobility and flexibility and to improve hand function.
The aim is to investigate the effect of soft robotic gloves in providing continuous passive motion of the fingers (finger flexion and extension) of degenerative arthritis patients, for the purpose of providing pain relief and alleviating stiffness at the finger joints. Specifically, we intend to 1) observe the changes in range of motion of the fingers using the Total Active Motion (TAM) measure; 2) observe the changes in grip strength and pinch strength; and 3) record changes in the patients' perception of performance in activities of daily living using the Canadian Occupational Performance Measure (COPM).
The hypothesis is that a soft robotics approach in providing continuous passive motion of the finger joints of degenerative arthritis patients can reduce pain, maintain mobility and flexibility of the joints, and to improve hand function. The soft robotics approach and the standard hand therapy is better than the standard hand therapy alone.
The proposed soft robotic glove is capable of providing continuous passive motion (flexion and extension) of the fingers, and in addition, it is also designed to be portable and easy to operate, with minimal supervision. It is aimed at the home therapy of degenerative arthritis patients. In this study, by using the soft robotic glove and in observing changes in finger range of motion, grip and pinch strength, as well as perception of performance in daily activities. This is important in establishing this device as a viable means to ultimately slow down the progression of degenerative arthritis, and to significantly improve the patients' abilities in carrying out activities of daily living, which had been impaired by degenerative arthritis.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Control Group | Active Comparator | This group will receive standard care. |
|
| Soft Robotic Glove Group | Experimental | This group will receive standard care and soft robotic therapy (continuous passive motion device developed by National University of Singapore). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Control Group | Other | Patients receive standard care |
| |
| Soft Robotic Glove Group |
| Measure | Description | Time Frame |
|---|---|---|
| Change in fingers' Total Active Motion | Measure hand range of motion in which the sum of the extension at the metacarpophalangeal (MCP), proximal interphalangeal (PIP), and distal interphalangeal (DIP) joints is subtracted from the total achievable flexion of the same joints. Unit: Degree | Week 1 baseline assessment and Week 11 post intervention assessment |
| Change in grip and pinch strength | Measure hand strength. Unit: g/kg | Week 1 baseline assessment and Week 11 post intervention assessment |
| Measure | Description | Time Frame |
|---|---|---|
| Change in patient's Canadian Occupational Performance Measure | Identify issues of personal importance to the patient and to detect changes in a patient's self-perception of occupational performance over time. | Week 1 baseline assessment and Week 11 post intervention assessment. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| National University Hospital | Singapore | 119074 | Singapore |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 6481515 | Result | Salter RB, Hamilton HW, Wedge JH, Tile M, Torode IP, O'Driscoll SW, Murnaghan JJ, Saringer JH. Clinical application of basic research on continuous passive motion for disorders and injuries of synovial joints: a preliminary report of a feasibility study. J Orthop Res. 1984;1(3):325-42. doi: 10.1002/jor.1100010313. | |
| 19433134 | Result |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D010003 | Osteoarthritis |
| D012216 | Rheumatic Diseases |
| ID | Term |
|---|---|
| D001168 | Arthritis |
| D007592 | Joint Diseases |
| D009140 | Musculoskeletal Diseases |
| D003240 | Connective Tissue Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D035061 | Control Groups |
| ID | Term |
|---|---|
| D015340 | Epidemiologic Research Design |
| D004812 | Epidemiologic Methods |
| D008919 | Investigative Techniques |
| D012107 | Research Design |
Not provided
Not provided
Comparing the control group and intervention group
Not provided
Not provided
Not provided
Not provided
| Device |
This group will receive standard care and soft robotic therapy (continuous passive motion device developed by National University of Singapore). |
|
| Kitay GS, Koren MJ, Helfet DL, Parides MK, Markenson JA. Efficacy of combined local mechanical vibrations, continuous passive motion and thermotherapy in the management of osteoarthritis of the knee. Osteoarthritis Cartilage. 2009 Oct;17(10):1269-74. doi: 10.1016/j.joca.2009.04.015. Epub 2009 May 4. |
| 15829571 | Result | Kjeken I, Dagfinrud H, Slatkowsky-Christensen B, Mowinckel P, Uhlig T, Kvien TK, Finset A. Activity limitations and participation restrictions in women with hand osteoarthritis: patients' descriptions and associations between dimensions of functioning. Ann Rheum Dis. 2005 Nov;64(11):1633-8. doi: 10.1136/ard.2004.034900. Epub 2005 Apr 13. |
| D017437 |
| Skin and Connective Tissue Diseases |
| D008722 | Methods |