Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This is a prospective study to determine the optimal technique for obtaining liver tissue with a smaller caliber (22 gauge) needle and whether a good core biopsy can be obtained without the use of suction and secondly to determine the diagnostic yield and safety of 22 g Fine Needle Biopsy needle for liver biopsy.
Liver biopsy (LB) has historically been performed by percutaneous route without image guidance (blind biopsy). However, in the last several years there has been more reliance on image guidance ultrasound-guided (USG) or computed tomography (CT) to direct the needle into the liver with the hope of limiting complications. Other ways of performing liver biopsy are transjugular fluoroscopy guided approach when percutaneous route is deemed not safe because of coagulopathy or ascites. Surgical LB (either laparoscopic or open) is yet another way of obtaining liver tissue.
Endoscopic ultrasound guided liver biopsy (EUS-LB) is proposed as a newer method that may offer several potential advantages over existing techniques for attaining liver tissue. It can be performed in an outpatient setting and offers the comfort of sedation and analgesia. Endoscopic Ultrasound (EUS) provides high resolution images of left lobe of the liver and a good portion of the right lobe of the liver. This coupled with Doppler capability the biopsy needle can be safely directed into the liver for sampling under real time image guidance. Intervening structures such as pleura, bowel loops and gallbladder can be easily seen by EUS and thus avoided that further decreases the risk of adverse events. It has been recognized that sampling error can lead to diagnostic inaccuracy of a biopsy from a single site. As compared to USG or CT scan the EUS allows easy and safe biopsy of both left and right lobes of the liver during same setting, potentially addressing concerns about sampling error.
The cost of the endoscopic procedure is the main expense of EUS-LB. Thus this approach is best used for patients requiring EUS for evaluation of elevated liver tests. If no obstructive lesion is identified by EUS that will require endoscopic retrograde cholangiopancreatography (ERCP) then it would cost-effective to perform EUS-LB during the same setting without much additional time and risks. This approach can spare the patient the additional discomfort and expense of a second dedicated LB procedure by any of the other available techniques (percutaneous, transjugular etc.). In such setting the equipment costs for the EUS-LB will mainly include only the Fine Needle Biopsy (FNB) needle, which is similar in expense to the cost of needles for the transjugular or percutaneous approach.
The traditionally used transcutaneous LB needle is 16 gauge (G) while largest EUS biopsy needle is 19 G. The smaller size of the needle is expected to decrease the complications rate (mainly pain and bleeding) even further. Many studies using a 19 G Tru-cut biopsy or Fine Needle Aspiration (FNA) needle to acquire liver tissue have obtained specimens adequate for histologic diagnosis but there has been a wide range of specimen adequacy (19-100%). The 19 G Tru-cut biopsy needle has been associated with several technical difficulties that could reflect negatively on tissue adequacy.
While it is easy and straight forward to biopsy the left lobe of the liver with any EUS needle. The 19 G needle is a large bore needle for EUS use and it is sometimes difficult to attain an adequate position for biopsy specially in duodenum where scope is torqued and this is the only area of access to right lobe.
In this study the investigators will use a 22 G needle. Smaller caliber of the needle would not only make it technically easier to access right lobe of the liver through the duodenum, it is also expected to decrease the risks further due to smaller size. Also, the 22 G EUS-FNB needle has three cutting points at the cutting edge of the needle that provide stability at puncture while the high quality, fully formed heels are designed to maximize tissue capture and minimize fragmentation, that would result in attaining a good histological specimen, a main stay for liver biopsy.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 22 gauge needle liver biopsy | Experimental | EUS-LB will be performed using a 22 g FNB needle. Specimens obtained from each pass will be placed in a separate biopsy jar. If the third pass does not result in sufficient diagnostic material, a 19 G will be used. A maximum of 3 passes will be made using the alternate needle. The total number of passes with the 22 G needle and the 19 G needle is 6. Data will be collected about the procedure and the performance of the needles for each procedure. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 22 gauge needle liver biopsy | Other | EUS will be performed. Specimens obtained from each pass will be placed in a separate biopsy jar. If the third pass does not result in sufficient diagnostic material, a 19 G will be used. A maximum of 3 passes will be made using the alternate needle. The total number of passes with the 22 G needle and the 19 G needle is 6. Data will be collected about the procedure and the performance of the needles for each procedure. |
| Measure | Description | Time Frame |
|---|---|---|
| Diagnostic adequacy of the liver biopsy specimen | Determine the diagnostic adequacy of the liver biopsy specimen by obtaining a histological specimen using a smaller (22 G) caliber needle. Diagnostic adequacy is defined as a sample that provides definitive pathological diagnosis (yes, no). | Sample obtained during EUS-guided liver biopsy. |
| Measure | Description | Time Frame |
|---|---|---|
| Visible core | The sample will have a visible core (yes/no). | Sample obtained during EUS-guided liver biopsy. |
| Suction | Sample was obtained using suction (yes/no). |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Muhammad Hasan, MD | Florida Hospital - Center for Interventional Endoscopy | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Center for Interventional Endoscopy - Florida Hospital | Orlando | Florida | 32803 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 19243014 | Background | Rockey DC, Caldwell SH, Goodman ZD, Nelson RC, Smith AD; American Association for the Study of Liver Diseases. Liver biopsy. Hepatology. 2009 Mar;49(3):1017-44. doi: 10.1002/hep.22742. No abstract available. | |
| 17561303 | Background | Kalambokis G, Manousou P, Vibhakorn S, Marelli L, Cholongitas E, Senzolo M, Patch D, Burroughs AK. Transjugular liver biopsy--indications, adequacy, quality of specimens, and complications--a systematic review. J Hepatol. 2007 Aug;47(2):284-94. doi: 10.1016/j.jhep.2007.05.001. Epub 2007 May 24. |
Not provided
Not provided
There is no plan to share the individual participant data with other researchers.
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D008113 | Liver Neoplasms |
| D006528 | Carcinoma, Hepatocellular |
| ID | Term |
|---|---|
| D004067 | Digestive System Neoplasms |
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D004066 | Digestive System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Sample obtained during EUS-guided liver biopsy. |
| Number of passes required histological samples | Assessing the median number of passes required to obtain diagnostically adequate histological samples histological samples | Time of Liver biopsy |
| Technical failure | Was there a technical failure (yes/no). | Time of Liver biopsy |
| Complications/Bleeding | Assessing subjects for post-procedural complications via follow up phone calls. Bleeding (yes/no). | 1 month |
| Complications/Pain | Assessing subjects for post-procedural complications via follow up phone calls. Pain (yes/no). | 1 month |
| Complications/Infection | Assessing subjects for post-procedural complications via follow up phone calls. Infection (yes/no). | 1 Month |
| 17897349 | Background | Mathew A. EUS-guided routine liver biopsy in selected patients. Am J Gastroenterol. 2007 Oct;102(10):2354-5. doi: 10.1111/j.1572-0241.2007.01353_7.x. No abstract available. |
| 19081532 | Background | Gleeson FC, Clayton AC, Zhang L, Clain JE, Gores GJ, Rajan E, Smyrk TC, Topazian MD, Wang KK, Wiersema MJ, Levy MJ. Adequacy of endoscopic ultrasound core needle biopsy specimen of nonmalignant hepatic parenchymal disease. Clin Gastroenterol Hepatol. 2008 Dec;6(12):1437-40. doi: 10.1016/j.cgh.2008.07.015. Epub 2008 Jul 26. |
| 19231495 | Background | Dewitt J, McGreevy K, Cummings O, Sherman S, Leblanc JK, McHenry L, Al-Haddad M, Chalasani N. Initial experience with EUS-guided Tru-cut biopsy of benign liver disease. Gastrointest Endosc. 2009 Mar;69(3 Pt 1):535-42. doi: 10.1016/j.gie.2008.09.056. |
| 22248599 | Background | Stavropoulos SN, Im GY, Jlayer Z, Harris MD, Pitea TC, Turi GK, Malet PF, Friedel DM, Grendell JH. High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction. Gastrointest Endosc. 2012 Feb;75(2):310-8. doi: 10.1016/j.gie.2011.09.043. |
| 22396285 | Background | Nakai Y, Samarasena JB, Iwashita T, Park DH, Lee JG, Hu KQ, Chang KJ. Autoimmune hepatitis diagnosed by endoscopic ultrasound-guided liver biopsy using a new 19-gauge histology needle. Endoscopy. 2012;44 Suppl 2 UCTN:E67-8. doi: 10.1055/s-0031-1291567. Epub 2012 Mar 6. No abstract available. |
| 2869260 | Background | Maharaj B, Maharaj RJ, Leary WP, Cooppan RM, Naran AD, Pirie D, Pudifin DJ. Sampling variability and its influence on the diagnostic yield of percutaneous needle biopsy of the liver. Lancet. 1986 Mar 8;1(8480):523-5. doi: 10.1016/s0140-6736(86)90883-4. |
| 26171433 | Background | Diehl DL, Johal AS, Khara HS, Stavropoulos SN, Al-Haddad M, Ramesh J, Varadarajulu S, Aslanian H, Gordon SR, Shieh FK, Pineda-Bonilla JJ, Dunkelberger T, Gondim DD, Chen EZ. Endoscopic ultrasound-guided liver biopsy: a multicenter experience. Endosc Int Open. 2015 Jun;3(3):E210-5. doi: 10.1055/s-0034-1391412. Epub 2015 Feb 27. |
| D008107 |
| Liver Diseases |
| D000230 | Adenocarcinoma |
| D002277 | Carcinoma |
| D009375 | Neoplasms, Glandular and Epithelial |
| D009370 | Neoplasms by Histologic Type |