The goal of this pilot imaging study is to evaluate the visibility of marking the interface between the pancreas and duodenum with TraceIT Tissue Marker. Patients with a pathologically confirmed diagnosis of BR/LAPC (borderline resectable/locally advanced pancreatic cancer) pancreatic adenocarcinomas indicated for neo-adjuvant image-guided radiotherapy with SBRT (stereotactic body radiation therapy) will be enrolled. This study will thus set the stage for further investigations using the TraceIT Tissue Marker to avoid duodenum toxicity with imaging localization, enabling further dose intensification with SBRT or IMRT to improve the clinical outcomes in BR/LAPC.
Pancreatic ductal adenocarcinoma is now the third leading cause of cancer-related death, with a devastating 5-year overall survival (OS) rate of nearly 8%, despite having the 12th most common incidence of all malignancies in the United States. One-third of patients will present with borderline resectable or unresectable, locally advanced pancreatic cancer (BR/LAPC). In the cases of LAPC, chemotherapy with or without radiation may be recommended to improve the quality of life by relieving symptoms and extending survival. Despite aggressive combined modality therapy, the median survival remains between 9 and 15 months.
Current guidelines for the management of BR/LAPC patients include single- or multi-agent chemotherapy or chemoradiation (CRT) in sequence with chemotherapy. Results of studies comparing chemotherapy alone to CRT for patients with BR/LAPC are mixed. The importance of local control or delaying local progression on improving morbidity and possibly mortality in patients with pancreatic cancer is supported by autopsy data demonstrating that 30% of patients die of locally destructive disease. It follows that in the cases of LAPC, advanced radiation therapy techniques using dose-escalation with intensity modulated radiotherapy (IMRT) and stereotactic body radiotherapy (SBRT) are potential strategies to improve local control.
A consistent challenge to dose-escalation with IMRT (intensity modulation radiation therapy) or SBRT is the sensitivity of the surrounding gastrointestinal organs, particularly the small bowel which is directly adjacent to the head of the pancreas head of the pancreas (HOP). For BR/LAPC patients treated with CRT, advances in image guidance have provided the opportunity to safely deliver higher biologically effective doses of radiation therapy using IMRT of >70 Gy (57.25 Gy in 25 fractions, BED 70.36 Gy) compared to standard fractionation regimens (50.40 Gy in 28 fractions or 50 Gy in 25 fractions, BED 59.47 Gy and 60 Gy, respectively). Those patients who underwent dose-escalated CRT with BED>70 Gy, did have a superior OS compared to those receiving BED<70 Gy, supporting the utility of dose-escalation in improving long-term outcomes. SBRT involves a short course of radiation therapy, five fractions or less, and has demonstrated higher rates of local control compared to CRT in other disease sites. Early studies evaluating SBRT for pancreatic cancer utilized single fractions of 25 Gy, resulting in local control rates of 100% at 1 year but unacceptably high rates of gastrointestinal toxicity. More recently, hypofractionated SBRT (33 Gy total, 6.6 Gy daily fractions) has been evaluated and utilized by our group in an effort to reduce the toxicity of therapy, with results demonstrating nearly 80% rate of freedom from local progression at one year and an acceptable 11% long-term gastrointestinal toxicity. Outcomes with SBRT are thus promising; however, higher local control rates with dose-escalation may be achievable, but current practice is limited due to risks of toxicity.
The goal of this pilot imaging study is to evaluate the visibility of marking the interface between the pancreas and duodenum with TraceIT Tissue Marker. Patients with a pathologically confirmed diagnosis of BR/LAPC pancreatic adenocarcinomas indicated for neo-adjuvant image-guided radiotherapy with SBRT will be enrolled. This study will thus set the stage for further investigations using the TraceIT Tissue Marker to avoid duodenum toxicity with imaging localization, enabling further dose intensification with SBRT or IMRT to improve the clinical outcomes in BR/LAPC.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| TraceIT tissue marker injection | Experimental | The TraceIT injection will be performed during the endoscopic fiducial placement which is the standard of care. CTs to serially confirm TraceIT positioning will be performed on the same day during patient visits for their middle (2nd or 3rd fraction) and last (5th fraction) radiation therapy treatments |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| TraceIT tissue marker injection | Device | The TraceIT injection will be performed during the endoscopic fiducial placement which is the standard of care. CTs to serially confirm TraceIT positioning will be performed on the same day during patient visits for their middle (2nd or 3rd fraction) and last (5th fraction) radiation therapy treatments. |
| Measure | Description | Time Frame |
|---|---|---|
| Number of Patients Where TraceIT Tissue Marker Placement Achieved | Measured as number of patients where marking the interface between the pancreas and duodenum with TraceIT Tissue Marker in patients undergoing image-guided radiotherapy for BR/LAPC pancreatic adenocarcinoma was achieved. | day 1 |
Not provided
Not provided
Inclusion Criteria:
Age ≥18 years old
BR/LAPC pancreatic carcinoma disease
Radiotherapy or chemoradiotherapy for treatment of the disease is indicated with the intent for eventual surgical resection
Subjects Screening/Baseline laboratory testing must meet the following laboratory value criteria:
Zubrod Performance Status 0-2
Subject or authorized representative, has been informed of the nature of the study and has provided written informed consent, approved by the appropriate Institutional Review Board (IRB) of the respective clinical site.
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Amol Narang, MD | Johns Hopkins SKCCC | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Sidney Kimmel Comprehensive Cancer Center at Johns Hopkins | Baltimore | Maryland | 21231-2410 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | TraceIT Tissue Marker Injection | The TraceIT injection will be performed during the endoscopic fiducial placement which is the standard of care. CTs to serially confirm TraceIT positioning will be performed on the same day during patient visits for their middle (2nd or 3rd fraction) and last (5th fraction) radiation therapy treatments TraceIT tissue marker injection: The TraceIT injection will be performed during the endoscopic fiducial placement which is the standard of care. CTs to serially confirm TraceIT positioning will be performed on the same day during patient visits for their middle (2nd or 3rd fraction) and last (5th fraction) radiation therapy treatments. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | TraceIT Tissue Marker Injection | The TraceIT injection will be performed during the endoscopic fiducial placement which is the standard of care. CTs to serially confirm TraceIT positioning will be performed on the same day during patient visits for their middle (2nd or 3rd fraction) and last (5th fraction) radiation therapy treatments TraceIT tissue marker injection: The TraceIT injection will be performed during the endoscopic fiducial placement which is the standard of care. CTs to serially confirm TraceIT positioning will be performed on the same day during patient visits for their middle (2nd or 3rd fraction) and last (5th fraction) radiation therapy treatments. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Number of Patients Where TraceIT Tissue Marker Placement Achieved | Measured as number of patients where marking the interface between the pancreas and duodenum with TraceIT Tissue Marker in patients undergoing image-guided radiotherapy for BR/LAPC pancreatic adenocarcinoma was achieved. | Posted | Count of Participants | Participants | day 1 |
|
immediate post-procedure period (approximately 3 hours after injection of hydrogel while patients in recovery/observation)
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | TraceIT Tissue Marker Injection | The TraceIT injection will be performed during the endoscopic fiducial placement which is the standard of care. CTs to serially confirm TraceIT positioning will be performed on the same day during patient visits for their middle (2nd or 3rd fraction) and last (5th fraction) radiation therapy treatments TraceIT tissue marker injection: The TraceIT injection will be performed during the endoscopic fiducial placement which is the standard of care. CTs to serially confirm TraceIT positioning will be performed on the same day during patient visits for their middle (2nd or 3rd fraction) and last (5th fraction) radiation therapy treatments. |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| nausea | Gastrointestinal disorders | CTCAE (4.0) | Systematic Assessment | Grade 3 |
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Amol Narang. MD | SKCCC @ Johns Hopkins | 410-955-7390 | anarang2@jhmi.edu |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Mar 13, 2018 | Oct 31, 2022 | Prot_SAP_000.pdf |
Not provided
Not provided
Not provided
marking the interface between the pancreas and duodenum with TraceIT Tissue Marker in patients undergoing image-guided radiotherapy
Not provided
Not provided
Not provided
Not provided
|
| Participants |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race/Ethnicity, Customized | Count of Participants | Participants |
|
| Region of Enrollment | Count of Participants | Participants |
|
|
|
| 0 |
| 6 |
| 1 |
| 6 |
| 0 |
| 6 |
Not provided