Prospective, randomised, controlled, single-surgeon, single-center clinical study to compare the clinical outcomes of two trifocal IOLs with different material (hydrophobic and hydrophilic) from the same manufacturer. Implantation of the IOLs is bilaterally.
This is a prospective, randomised, controlled, single-surgeon, single-center clinical study whereby patients undergoing routine cataract surgery will have bilateral implantation of trifocal intraocular lenses. The patients will either be implanted with the hydrophobic IOL FineVision POD F GF or the hydrophilic IOL FineVision POD F (both lenses: (PhysIOL, Liège, Belgium).
The devices under investigation (FineVision POD F GF and POD F) are trifocal glistening-free acrylic intraocular lenses (IOLs) manufactured by the sponsor of this study PhysIOL sa/nv. The main difference between the lenses is the material (hydrophobic and hydrophilic). The IOLs will be implanted as part of the routine cataract surgery on patients suffering from cataract development.
Subjects participating in the trial will attend a total of 12 study visits (1 preoperative, 2 operative and 9 postoperative) over a period of 36 months. Subjects would have the option for unscheduled visits if required medically.
Primary endpoint data will be collected at the 3 months follow up visit and secondary endpoint data will be collected at the 3, 12, 24 and 36 months follow up visits. Data analyses will be done after the last patient finished the final examination to support the study publication plan.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| IOL implantation experimental | Experimental | hydrophobic, trifocal intraocular lens POD F GF |
|
| IOL implantation active comparator | Active Comparator | hydrophilic, trifocal intraocular lens POD F |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| IOL implantation experimental | Device | Implantation of trifocal IOL POD F GF consisting of hydrophobic material |
|
| Measure | Description | Time Frame |
|---|---|---|
| Monocular Uncorrected Distance Visual Acuity (UDVA) under photopic light conditions. | No statistically significant difference between the two study groups on monocular UDVA at 3 months follow up visit. A significance level of 0.05 or lower (p < 0.05) will be considered statistically significant. UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2014 | 3 months postoperative |
| Measure | Description | Time Frame |
|---|---|---|
| Manifested refraction | The manifested refraction is measured by means of a phoropter. The data contains values for sphere, cylinder and axis of cylinder according to ISO 11979-7:2014. This data will also be used to calculate the manifested refractive spherical equivalent (MRSE) | Pre-OP, 1 week postoperative, 1 month postoperative, 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Measure | Description | Time Frame |
|---|---|---|
| Intraocular pressure (IOP) measurement | The IOP will be measured with non-contact tonometer as part of the routine follow up examinations | Pre-OP, 1 day postoperative, 1 week postoperative, 1 month postoperative, 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Keratometry |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Robert Edward Ang, MD | Asian Eye Institute | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Asian Eye Institute | Makati City | 1200 | Philippines |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002386 | Cataract |
| D011305 | Presbyopia |
| ID | Term |
|---|---|
| D007905 | Lens Diseases |
| D005128 | Eye Diseases |
| D012030 | Refractive Errors |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| IOL implantation active comparator | Device | Implantation of trifocal IOL POD F consisting of hydrophilic material |
|
| Uncorrected Distance Visual Acuity (UDVA) - monocular | UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2014. This assessment is done monocularly. | 1 day postoperative, 1 week postoperative, 1 month postoperative, 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Uncorrected Distance Visual Acuity (UDVA) - binocular | UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2014. This assessment is done binocularly. | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Corrected Distance Visual Acuity (CDVA) - monocular | CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2014. This assessment is done monocularly. | Pre-OP, 1 week postoperative, 1 month postoperative, 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Corrected Distance Visual Acuity (CDVA) - binocular | CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2014. This assessment is done binocularly. | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Distance Corrected Intermediate Visual Acuity at 70cm (DCIVA) - monocular | DCIVA is measured with ETDRS charts placed in 70cm distance with corrective glasses for far distance according to ISO 11979-7:2014. This assessment is done monocularly. | 1 week postoperative, 1 month postoperative, 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Distance Corrected Intermediate Visual Acuity at 70cm (DCIVA) - binocular | DCIVA is measured with ETDRS charts placed in 70cm distance with corrective glasses for far distance according to ISO 11979-7:2014. This assessment is done binocularly. | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Uncorrected Intermediate Visual Acuity at 70cm (UIVA) - monocular | UIVA is measured with ETDRS charts placed in 70cm distance. The examination is done without corrective glasses and according to ISO 11979-7:2014. This assessment is done monocularly. | 1 week postoperative, 1 month postoperative, 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Uncorrected Intermediate Visual Acuity at 70cm (UIVA) - binocular | UIVA is measured with ETDRS charts placed in 70cm distance. The examination is done without corrective glasses and according to ISO 11979-7:2014. This assessment is done binocularly. | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Distance Corrected Near Visual Acuity at 35cm (DCNVA) - monocular | DCNVA is measured with ETDRS charts placed in 35cm distance with corrective glasses for far distance according to ISO 11979-7:2014. This assessment is done monocularly. | 1 week postoperative, 1 month postoperative, 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Distance Corrected Near Visual Acuity at 35cm (DCNVA) - binocular | DCNVA is measured with ETDRS charts placed in 35cm distance with corrective glasses for far distance according to ISO 11979-7:2014. This assessment is done binocularly. | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Uncorrected Near Visual Acuity at 35cm (UNVA) | UNVA is measured with ETDRS charts placed in 35cm distance. The examination is done without corrective glasses and according to ISO 11979-7:2014. This assessment is done monocularly. | 1 week postoperative, 1 month postoperative, 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Uncorrected Near Visual Acuity at 35cm (UNVA) | UNVA is measured with ETDRS charts placed in 35cm distance. The examination is done without corrective glasses and according to ISO 11979-7:2014. This assessment is done binocularly. | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Contrast Sensitivity | Contrast Sensitivity under photopic and mesopic light conditions | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Aberrometry | Aberrometry outcomes are measured with a standard aberrometer. The following values will be evaluated in this study: Spherical aberrations, high order aberrations, lens tilt. | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| AcuTarget diagnostic device | Measurement of Ocular Scatter Index (OSI) score to evaluate and compare the scattering of the implanted lenses. | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Visual Functioning Questionnaire - 25 (VFQ-25) | Outcomes measures of a questionnaire to address the general patient satisfaction and possible side effects of the treatment. For this study, the validated and verified Visual Functioning Questionnaire - 25 (VFQ-25) will be used. The maximum score for each questionaire is 100. | 3 months postoperative, 12 months postoperative. |
| Defocus Curve | To assess the visual acuity for different distances, defocus curves under photopic light conditions are measured. This test is performed with best distance corrected refraction and spherical additions ranging from -5.0 D to +1.5 D. This examination is performed monocularly and binocularly. | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Slitlamp examination - Corneal Status | The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Corneal Status | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Slitlamp examination - Fundus | The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Fundus | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Slitlamp examination - Signs of inflammation | The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Signs of inflammation | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Slitlamp examination - Pupillary block | The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Pupillary block | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Slitlamp examination - Retinal detachment | The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Retinal detachment | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Slitlamp examination - Status of anterior and posterior capsule | The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Status of anterior and posterior capsule | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Slitlamp examination - IOL decentration | The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • IOL decentration | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Slitlamp examination - IOL tilt | The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • IOL tilt | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Slitlamp examination - IOL discoloration | The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • IOL discoloration | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
| Slitlamp examination - IOL opacity | The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • IOL opacity | 3 months postoperative, 12 months postoperative, 24 months postoperative, 36 months postoperative. |
Keratometric measurements are performed to calculate the required IOL power |
| Pre-OP |
| Biometry | Biometry measurements are performed to calculate the required IOL power | Pre-OP |