Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The study design of this research project involves orthodontic patients registered at the Harvard School of Dental Medicine who are deemed eligible to undergo orthodontic treatment and who have been provided with sufficient information to make informed consent to join the sleep study. These patients will be provided with the Medibyte sleep monitor and instructed on the proper manner in which it should be set up and worn for the one night study period. This process will be carried out twice throughout the course of the study, once before any orthodontic appliance has been cemented and once after the required amount of tooth movement has been attained with the orthodontic appliance still in place.
The de-identified data from the Medibyte monitor will be downloaded using the Braebon software and analyzed.
The study design of this research project involves recruiting orthodontic patients registered at the Harvard School of Dental Medicine who are deemed eligible to undergo orthodontic treatment and who have been provided with sufficient information to make informed consent to join the sleep study. The participants will be provided with the Medibyte sleep monitor and instructed on the proper manner in which it should be set up and worn for the one or two night study period. The purpose of the Medibyte monitor is solely to provide a calibrated value of AHI. The Medibyte monitor will not be utilized for investigations and/or treat, cure, mitigate a medical condition. This process will be carried out twice throughout the course of the study, once before any orthodontic appliance has been cemented and once after the required amount of tooth movement has been attained with the orthodontic appliance still in place.
The de-identified data from the Medibyte monitor will be downloaded using the Braebon software and analyzed providing a baseline value and post orthodontic movement AHI value. Additionally the patients arch width, length and other orthodontic measurements will also be taken both from their 3-D dental models and also their 2-D lateral cephalogram x-ray all of which are part of the routine orthodontic records (the x-rays will be taken regardless of the patients participation in the study since they are a required component of the orthodontic records taken at HSDM). The values obtained from the patients casts, lateral cephalogram and Medibyte AHI values will be analyzed both pre-orthodontic appliance cementation and also post tooth movement. The changes, if any, in the dental parameters as compared with the AHI values will allow the investigation of the orthodontic effects of expanding the maxilla, moving the front teeth either forwards or backwards which in effect cause changes to the airway and its effect on AHI values during sleep. In addition to the measurements taken intra-orally, surveys will also be undertaken to study any changes the patients may experience in their sleep and quality of life. If the Medibyte shows a severe reading for obstructive sleep apnea, these patients will then be referred to a sleep specialist for further more conclusive testing.
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Medibyte Portable Monitor | Other | Patients will be provided with the portable monitor in order to measure their apnea/hypopnea index. |
| Measure | Description | Time Frame |
|---|---|---|
| Relationship between dental movements and AHI | This outcome aims to measure any changes in the dental measurements such as arch length, arch perimeter, inter-canine and inter-molar changes on the AHI value. | 2 Year |
| Relationship between skeletal changes and AHI | This outcome aims to measure any changes in the skeletal changes such as SNA, SNB, ANB etc. as measured by the lateral cephalogram and any changes in the AHI | 2 Year |
| Relationship between airway cephalometric changes and AHI | This outcome aims to measure any changes in the airway cephalometric measurements such as the upper/middle/superior airway space etc. and the AHI | 2 Year |
| Measure | Description | Time Frame |
|---|---|---|
| Relationship between the changes in the reported quality of life measurements and the AHI | This outcome aims to measure any changes in the reported quality of life measurements as measured by questionnaires such as conners, epworth, pediatric quality of life and pediatric sleep quesitonnaire and the AHI vale. | 2 Year |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
The study population will include patients already registered at the Harvard School of Dental Medicine department of Orthodontics. Informed consent will be obtained before the questionnaires and portable monitor will be provided.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Shaima Tabari | Contact | 415-851-0166 | shaima_tabari@hsdm.harvard.edu |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Harvard School of Dental Medicine | Recruiting | Boston | Massachusetts | 02115 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D020181 | Sleep Apnea, Obstructive |
| D001049 | Apnea |
| D012891 | Sleep Apnea Syndromes |
| ID | Term |
|---|---|
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
| D020919 | Sleep Disorders, Intrinsic |
| D020920 | Dyssomnias |
Not provided
Not provided
Not provided
Not provided
Not provided
| D012893 |
| Sleep Wake Disorders |
| D009422 | Nervous System Diseases |
| D012818 | Signs and Symptoms, Respiratory |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |