Recently published work has suggested that mitral valve annuloplasty ring type may affect the development of post-repair mitral stenosis resulting in adverse intracardiac hemodynamics and poor functional status. However, these results have not been comprehensively determined in a systematic manner on a general mitral valve repair population. As well, an underlying mechanism for these findings is not understood.
The investigators hypothesize that mitral valve repair with a complete annuloplasty ring (Carpentier-Edwards Physio II) when compared to repair with a partial annuloplasty ring (Simplici- T) may not necessarily result in elevated mitral gradients consistent with functional mitral stenosis (FMS). Currently no prospective data exists to test the hypothesis that a correctly sized, flexible complete annuloplasty ring has detrimental effects.
As 60% of annuloplasty rings used in surgical repair of degenerative mitral valve disease in North America utilizes one of the many forms of complete flexible rings available, this information is urgently required.
The investigators will evaluate: 1) the effect on mitral valve hemodynamics, 2) changes to mitral annular, valvular and subvalvular structure and function with 3D echocardiography, and 3) the effect on patient functional capacity at 1 year.
If FMS early post repair is a real phenomenon, the investigators hope to better understand the mechanisms through the use of advanced imaging techniques-namely 3D modeling of the mitral valvular apparatus, aortic mitral interactions and LV remodeling.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Carpentier Edwards Physio 2 Complete flexible mitral ring | Active Comparator | Mitral Valve Annuloplasty Ring Repair using Carpentier Edwards Physio 2 Complete flexible mitral ring |
|
| Simplici T Partial flexible mitral annuloplasty ring | Active Comparator | Mitral Valve Annuloplasty Ring Repair using Simplici T Partial flexible mitral annuloplasty ring |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Carpentier Edwards Physio 2 Complete flexible mitral ring | Device | Mitral valve Annuloplasty Ring repair using a Carpentier Edwards Physio 2 Complete flexible mitral ring |
|
| Measure | Description | Time Frame |
|---|---|---|
| Mean mitral valve gradient | Mean mitral valve gradient measured by transthoracic echocardiogram | 1 year |
| Measure | Description | Time Frame |
|---|---|---|
| Left ventricular remodelling | Assessment of left ventricular remodelling obtained from transthoracic echocardiography performed pre-operatively and at 1 year post surgery using 3D LV end-diastolic volume and 3D end-systolic volume measurements and 3D LV ejection fraction | 1 year |
| Aortic-mitral coupling |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Wendy W Tsang, MD | Contact | 4163403155 | Wendy.Tsang@uhn.ca | |
| Kate H Rankin, MBBS | Contact | 4163403155 | kate.rankin@uhn.ca |
| Name | Affiliation | Role |
|---|---|---|
| Wendy W Tsang, MD | University Health Network, Toronto General Hospital | Principal Investigator |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Simplici T Partial flexible mitral annuloplasty ring | Device | Mitral valve Annuloplasty Ring repair using a Simplici T Partial flexible mitral annuloplasty ring |
|
3D transesophageal echocardiogram assessment intra-operatively both pre and post bypass assessing the entire mitral valvular and subvalvular apparatus, the left ventricle and the aortic valve to assess aortic-mitral valvular coupling and to determine whether there is a difference observed in aorto-mitral coupling between complete and partial ring repairs |
| 1 year |
| Change in functional capacity | Functional capacity will be specifically assessed using workload achieved on stress transthoracic echocardiogram studies performed pre surgery and at 1 year post surgery. Measurements acquired will include total exercise time and total workload achieved. Also patients will complete SF-36 questionnaires pre-surgery and at 1 year post surgery for further assessment of change in functional capacity | 1 year |