Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Reaching a peripheral venous access or making a blood sample in a scared infant or toddler can be challenging even for experienced nurses o pediatricians. Up to 60% of children report pain and distress during venipuncture and multiple attempts can result in more difficult physical and emotional conditions for subsequent insertions so that the procedure should be performed with the less number of punctures as possible. In about one third of children, more than one attempt is required to achieve peripheral intravenous cannulation. In the last years, specific tools have been developed to enhance the success in venipuncture or incannulation. Near-infrared (NIR) technology consists on light-emitting diodes placed underneath the hand, that makes vessels visible by projecting the processed image in a green light directly on to the puncture site. According to previous studies, NIR had shown a trend in reduction of time employed for a blood sample, in children younger of 6 yr.
The aim of this trial is to investigate if the use of the VeinViewer® in a pediatric blood drawing center could decrease time spent to perform the procedure and improve the rate of first attempt success.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| VeinViewer® group | Experimental | Use of near infrared light to perform blood draw (VeinViewer®) |
|
| Usual care group | Active Comparator | Blood drawing performed traditionally |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| VeinViewer® | Device | Near-infrared (NIR) technology consists on light-emitting diodes placed underneath the hand, that makes vessels visible by projecting the processed image in a green light directly on to the puncture site |
| Measure | Description | Time Frame |
|---|---|---|
| Time to perform the procedure | In seconds, from the placement of the tourniquet until the blood flows in the needle | Intraprocedural |
| Measure | Description | Time Frame |
|---|---|---|
| Success at first attempt | Percentage of success at first attempt | Intraprocedural |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Egidio Barbi, MD PhD | IRCCS Burlo Garofolo | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| IRCCS Burlo Garofolo | Trieste | 34137 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 29801519 | Derived | Conversano E, Cozzi G, Pavan M, Minute M, Gortan E, Montico M, Vecchi Brumatti L, Ronfani L, Barbi E. Impact of near infrared light in pediatric blood drawing Centre on rate of first attempt success and time of procedure. Ital J Pediatr. 2018 May 25;44(1):60. doi: 10.1186/s13052-018-0501-1. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Usual care | Procedure | The blood drawing is performed traditionally |
|