The purpose of the study "Usability and Ergonomic Evaluation of Self-Positioning System for Retinal Imaging" is to enable self-operation of a monitoring device in home-simulated environment
One of the main challenges in developing a retinal imager is to design it to be self-operated by elderly patients in their home setting The study's objective is to explore ergonomic solutions that will allow the user to perform imaging on their own. The study will be done in a home-simulated environment using a dedicated ergonomic system (termed "PAF" - Positioning And Fixation system) that stimulates the retinal imager and enables to record the tested subject using standard cameras. The prototype doesn't include the retinal imager and does not include any imaging capabilities aside from standard means of photography Subjects will be evaluating for positioning accuracy and comfort by comparing different methods. Pupil position will be recorded using commercial off the shelf cameras when the subject is performing simple ergonomic tasks while looking at a screen presenting images.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Usability and Ergonomic Evaluation of Self-Positioning System | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| PAF (Positioning And Fixation device) | Device | Up to 60 Subjects will be evaluating for positioning accuracy and comfort by comparing different methods utilizing the PAF device. Some methods of positioning will be applied and compare for each usability factor X, Y, Z location, and fixation. The patient will be evaluated before pupil dilation. VA and ophthalmic diagnoses will be recorded. Pupil position will be recorded using 3 commercial off the shelf cameras when the subject is performing simple ergonomic tasks while looking at a screen presenting images. Each testing session will be limited 20 min long. Subjects will be able to rest within the testing session if required. Total session time per patient will not exceed 30 minutes. |
| Measure | Description | Time Frame |
|---|---|---|
| spatial location of the pupil, during an eye examination | documentation of pupil location by a camera | 1 year |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Sorasky Medical Center | Tel Aviv | Israel |
Not provided
| ID | Term |
|---|---|
| D056888 | Patient Positioning |
| ID | Term |
|---|---|
| D005791 | Patient Care |
| D013812 | Therapeutics |
| D006296 | Health Services |
| D005159 | Health Care Facilities Workforce and Services |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|