This study is designed to evaluate the reproductibility and the performance of the 3 minutes sit-to-stand test in patients with idiopathic pulmonary fibrosis.
To do this, the investigators are recruiting 40 patients with idiopathic pulmonary fibrosis in 2 centers (Grenoble university hospital and Lyon university hospital).
Patients had to achieve an effort test on a cycle ergometer. 2 visits are planned in the hospital. During each visit, patients will perform a 3 minutes sit-to-stand test, a 1 minute sit-to-stand test and a 6 minutes walk test. During the second visit, patients will also perform a 3 minutes sit-to-stand test with measurement of oxygen uptake.
The investigators will then analyse the results by comparing numbers of cycle, functional response and symptoms during the 3 minutes sit-to-stand test of the 2 visits. The investigators will also compare the functional response obtained during the 3 minutes sit-to-stand test, the 1 minute sit-to-stand test and the 6 minutes walk test.
Finally, the investigators will compare the maximal values of oxygen uptake, respiration rate and expired volume obtained during the 3 minutes sit-to-stand test to the effort test on cycle ergometer.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| patient with idiopathic pulmonary fibrosis | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 3 minutes sit-to-stand test | Diagnostic Test | 3 minutes sit-to-stand test, 1 minute sit-to-stand test, 6 minutes walk test will be performed 2 times for each patients 3 minutes sit-to-stand test with oxygen uptake measurement will be performed one time for each patient |
| Measure | Description | Time Frame |
|---|---|---|
| Reproductibility of the 3 minutes sit-to-stand test in patient with idiopathic pulmonary fibrosis | Evaluate the reproductibility for the number of rise and down during the 3 minutes sit-to-stand test of the 2 visits (the investigators will compare the number of rise and sit during the 3 minutes sit-to-stand test of the 2 visits to see if they are similar) | 2 days |
| Measure | Description | Time Frame |
|---|---|---|
| Functional response during the 3 minutes sit-to-stand test: Oxygen saturation | Evaluate the reproductibility of functional response (oxygen saturation) during the 3 minutes sit-to-stand test | 2 days |
| 3 minutes sit-to-stand test compared to the 6 minutes walk test: oxygen saturation |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| CHU Grenoble Alpes | La Tronche | 38700 | France | |||
| Groupement Hospitalier Est |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 21719092 | Result | King TE Jr, Pardo A, Selman M. Idiopathic pulmonary fibrosis. Lancet. 2011 Dec 3;378(9807):1949-61. doi: 10.1016/S0140-6736(11)60052-4. Epub 2011 Jun 28. | |
| 24314711 | Result | Cottin V, Crestani B, Valeyre D, Wallaert B, Cadranel J, Dalphin JC, Delaval P, Israel-Biet D, Kessler R, Reynaud-Gaubert M, Cordier JF, Aguilaniu B, Bouquillon B, Carre P, Danel C, Faivre JB, Ferreti G, Just N, Kouzan S, Lebargy F, Marchand Adam S, Philippe B, Prevot G, Stach B, Thivolet-Bejui F; French National Reference and Competence Centers for Rare Diseases; Societe de Pneumologies de Langue Francaise. [French practical guidelines for the diagnosis and management of idiopathic pulmonary fibrosis. From the National Reference and the Competence centers for rare diseases and the Societe de Pneumologie de Langue Francaise]. Rev Mal Respir. 2013 Dec;30(10):879-902. doi: 10.1016/j.rmr.2013.09.007. Epub 2013 Oct 25. No abstract available. French. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D054990 | Idiopathic Pulmonary Fibrosis |
| ID | Term |
|---|---|
| D011658 | Pulmonary Fibrosis |
| D017563 | Lung Diseases, Interstitial |
| D008171 | Lung Diseases |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D000070857 | Walk Test |
| ID | Term |
|---|---|
| D005080 | Exercise Test |
| D006334 | Heart Function Tests |
| D003935 | Diagnostic Techniques, Cardiovascular |
| D019937 | Diagnostic Techniques and Procedures |
Not provided
Not provided
The investigators want to test the reproductibility of a 3 minutes sit-to-stand test in patients with idiopathic pulmonary fibrosis.
For this, patient perform the test during 2 visits and the investigators are going to compare the results of the two visits.
Not provided
Not provided
Not provided
Not provided
|
compared oxygen saturation during the 3 minutes sit-to-stand test to the 6 minutes walk test |
| 2 days |
| 1 minute sit-to-stand test compared to 3 minutes sit-to-stand: oxygen saturation | Compared oxygen saturation during the 3 minutes sit-to-stand test with 1 minute sit-to-stand test | 2 days |
| Functional response during the 3 minutes sit-to-stand test: Heart rate | Evaluate the reproductibility of functional response (heart rate) during the 3 minutes sit-to-stand test | 2 days |
| Functional response during the 3 minutes sit-to-stand test: symptoms | Evaluate the reproductibility of functional response (symptoms) during the 3 minutes sit-to-stand test | 2 days |
| 3 minutes sit-to-stand test compared to the 6 minutes walk test: heart rate | Compared heart rate during the 3 minutes sit-to-stand test to the 6 minutes walk test | 2 days |
| 3 minutes sit-to-stand test compared to the 6 minutes walk test: symptoms | Compared symptoms during the 3 minutes sit-to-stand test to the 6 minutes walk test | 2 days |
| 1 minute sit-to-stand test compared to 3 minutes sit-to-stand: heart rate | Compared heart rate during the 3 minutes sit-to-stand test with 1 minute sit-to-stand test | 2 days |
| 1 minute sit-to-stand test compared to 3 minutes sit-to-stand: symptoms | Compared symptoms during the 3 minutes sit-to-stand test with 1 minute sit-to-stand test | 2 days |
| Lyon |
| 69677 |
| France |
| 21471066 | Result | Raghu G, Collard HR, Egan JJ, Martinez FJ, Behr J, Brown KK, Colby TV, Cordier JF, Flaherty KR, Lasky JA, Lynch DA, Ryu JH, Swigris JJ, Wells AU, Ancochea J, Bouros D, Carvalho C, Costabel U, Ebina M, Hansell DM, Johkoh T, Kim DS, King TE Jr, Kondoh Y, Myers J, Muller NL, Nicholson AG, Richeldi L, Selman M, Dudden RF, Griss BS, Protzko SL, Schunemann HJ; ATS/ERS/JRS/ALAT Committee on Idiopathic Pulmonary Fibrosis. An official ATS/ERS/JRS/ALAT statement: idiopathic pulmonary fibrosis: evidence-based guidelines for diagnosis and management. Am J Respir Crit Care Med. 2011 Mar 15;183(6):788-824. doi: 10.1164/rccm.2009-040GL. |
| 23204124 | Result | Nalysnyk L, Cid-Ruzafa J, Rotella P, Esser D. Incidence and prevalence of idiopathic pulmonary fibrosis: review of the literature. Eur Respir Rev. 2012 Dec 1;21(126):355-61. doi: 10.1183/09059180.00002512. |
| 3208648 | Result | Huang XF, Gao F, Xue ZQ, Wang Y, Xu GW. [Multifactorial analysis of survival in breast cancer]. Zhonghua Zhong Liu Za Zhi. 1988 Mar;10(2):117-9. Chinese. |
| 21131468 | Result | du Bois RM, Weycker D, Albera C, Bradford WZ, Costabel U, Kartashov A, Lancaster L, Noble PW, Sahn SA, Szwarcberg J, Thomeer M, Valeyre D, King TE Jr. Six-minute-walk test in idiopathic pulmonary fibrosis: test validation and minimal clinically important difference. Am J Respir Crit Care Med. 2011 May 1;183(9):1231-7. doi: 10.1164/rccm.201007-1179OC. Epub 2010 Dec 3. |
| 25956020 | Result | Nathan SD, du Bois RM, Albera C, Bradford WZ, Costabel U, Kartashov A, Noble PW, Sahn SA, Valeyre D, Weycker D, King TE Jr. Validation of test performance characteristics and minimal clinically important difference of the 6-minute walk test in patients with idiopathic pulmonary fibrosis. Respir Med. 2015 Jul;109(7):914-22. doi: 10.1016/j.rmed.2015.04.008. Epub 2015 Apr 24. |
| 12091180 | Result | ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories. ATS statement: guidelines for the six-minute walk test. Am J Respir Crit Care Med. 2002 Jul 1;166(1):111-7. doi: 10.1164/ajrccm.166.1.at1102. No abstract available. |
| 10380242 | Result | Jones CJ, Rikli RE, Beam WC. A 30-s chair-stand test as a measure of lower body strength in community-residing older adults. Res Q Exerc Sport. 1999 Jun;70(2):113-9. doi: 10.1080/02701367.1999.10608028. |
| 18808608 | Result | Buatois S, Miljkovic D, Manckoundia P, Gueguen R, Miget P, Vancon G, Perrin P, Benetos A. Five times sit to stand test is a predictor of recurrent falls in healthy community-living subjects aged 65 and older. J Am Geriatr Soc. 2008 Aug;56(8):1575-7. doi: 10.1111/j.1532-5415.2008.01777.x. No abstract available. |
| 16634026 | Result | Macfarlane DJ, Chou KL, Cheng YH, Chi I. Validity and normative data for thirty-second chair stand test in elderly community-dwelling Hong Kong Chinese. Am J Hum Biol. 2006 May-Jun;18(3):418-21. doi: 10.1002/ajhb.20503. |
| 19008696 | Result | Hill CJ, Denehy L, Holland AE, McDonald CF. Measurement of functional activity in chronic obstructive pulmonary disease: the grocery shelving task. J Cardiopulm Rehabil Prev. 2008 Nov-Dec;28(6):402-9. doi: 10.1097/HCR.0b013e31818c3c65. |
| 19863362 | Result | Perrault H, Baril J, Henophy S, Rycroft A, Bourbeau J, Maltais F. Paced-walk and step tests to assess exertional dyspnea in COPD. COPD. 2009 Oct;6(5):330-9. doi: 10.1080/15412550903156317. |
| 18432536 | Result | Brodin E, Ljungman S, Sunnerhagen KS. Rising from a chair: a simple screening test for physical function in predialysis patients. Scand J Urol Nephrol. 2008;42(3):293-300. doi: 10.1080/00365590701797556. |
| 16806873 | Result | Ozalevli S, Ozden A, Itil O, Akkoclu A. Comparison of the Sit-to-Stand Test with 6 min walk test in patients with chronic obstructive pulmonary disease. Respir Med. 2007 Feb;101(2):286-93. doi: 10.1016/j.rmed.2006.05.007. Epub 2006 Jun 27. |
| 4181548 | Result | Craig CP, Reynolds SL, Airhart JW, Staab EV. Alterations in immune responses by attenuated Venezuelan equine encephalitis vaccine. I. Adjuvant effect of VEE virus infection in guinea pigs. J Immunol. 1969 May;102(5):1220-7. No abstract available. |
| 10501650 | Result | Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999 Jun;8(2):135-60. doi: 10.1177/096228029900800204. |
| 6655447 | Result | Passing H, Bablok. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, Part I. J Clin Chem Clin Biochem. 1983 Nov;21(11):709-20. doi: 10.1515/cclm.1983.21.11.709. |
| 19998394 | Result | Carstensen B. Comparing methods of measurement: Extending the LoA by regression. Stat Med. 2010 Feb 10;29(3):401-10. doi: 10.1002/sim.3769. |
| D003933 | Diagnosis |