The purpose of this study is to evaluate the accuracy and efficacy of the Cambridge Medical Technologies, LLC LabPatch Continuous Glucose Monitoring (CGM) System compared to a laboratory glucose analyzer (YSI 2300 STAT Plus) and 2 commercial glucometers, OneTouch Verio and Freestyle Lite.
The LabPatch system includes:
Study design:
This is a cross-sectional, pilot, precision, single center, single-arm study, enrolling 30 adult subjects with type 1 or type 2 diabetes treated with insulin.
The study will include both a screening visit and a single study visit.The accuracy of the LabPatch CGM will be evaluated during the study visit, comparing to YSI 2300 STAT Plus, OneTouch Verio and FreeStyle Lite.
Screening Visit:
Following the informed consent process, screening evaluation will determine subject eligibility for enrollment, including:
Study Visit (visit window: screening visit + 0 to 30 Days):
Subject Admission
The subject will arrive at the clinical research center at Joslin Diabetes Center during the day, no later than 10:00 AM and the following will be performed:
During this visit the following procedures will be conducted:
Before discharge:
Subject Instructions prior to the visit
Estimated Visit Duration
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Study Cohort | 30 adult subjects with type 1 or type 2 diabetes treated with insulin. The accuracy of the LabPatch Continuous Glucose Monitoring (CGM) will be evaluated during the study visit, comparing to YSI 2300 STAT Plus, OneTouch Verio and FreeStyle Lite. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| LabPatch Continuous Glucose Monitoring (CGM) | Device |
|
| Measure | Description | Time Frame |
|---|---|---|
| Mean absolute relative difference (MARD) | Blood glucose values (mg/dL) from the LabPatch system and reference YSI, One Touch Verio, and FreeStyle Lite will be used to report the mean absolute relative difference (MARD) in Percentage (%). | Baseline, every 15 minutes after breakfast for 2 hours, every 30 minutes until lunch time, and every 30 minutes after lunch for 2 hours |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Adult subjects with type 1 or type 2 diabetes treated with insulin.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Osama Hamdy, M.D.,Ph.D | Joslin Diabetes Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Joslin Diabetes Center | Boston | Massachusetts | 02215 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003924 | Diabetes Mellitus, Type 2 |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
20 to 22 blood sample( A total of about 110 mL of blood will be drawn during the visit).
|
| D004700 | Endocrine System Diseases |