Radiation dose to interventional cardiologists performing transradial percutaneous coronary procedures is higher compared to those performing transfemoral exams. The radiation dose seems particularly high at pelvic level. We prepared an home-made protective extension of the leaded curtain under table that should reduce the operator exposure during interventional coronary procedures. The aim of the study is to evaluate the procedural efficacy of the protective extension on the operator radiation dose at pelvic level
Interventional cardiologists are routinely exposed to x-rays during their activity increasing the risk of deterministic and stochastic effects. Consequently all the operators should be aware of the possible risks and they should apply all efforts to reduce the radiation dose according to the "As Low As Reasonably Achievable" (ALARA) principle. Moreover interventional cardiologists have to utilise adequate protection devices (lead apron, protective thyroid collar, lead glasses).
Operator performing transradial access procedures showed a significantly higher radiation exposure compared to those performing transfemoral interventions. So, transradial operators should use adjunctive protective shields (as leaded pelvic drapes placed on the patient abdomen) in order to reduce their radio-exposition.
During transradial access a particularly high radiation exposure is observed at operator pelvic level and the use of the protective adjunctive drapes placed on the patient abdomen is only partially effective to control this exposition.
Aim of our study was to evaluate the effect of a protective extension of the leaded curtain placed under the angiographic table in term of operator radiation exposure at pelvic level
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| SCUT | Experimental | Use of a "Small Curtain under table" (SCUT) placed under the cranial part of the angiographic table |
|
| Control | No Intervention | Control Group without the SCUT |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| SCUT | Device | Two different home made curtains were attached to the angiographic table |
|
| Measure | Description | Time Frame |
|---|---|---|
| Operator pelvic dose | Operator radiation dose at pelvic level | 24 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Operator thorax dose | Operator radiation dose at thorax level | 24 hours |
| Operator head dose | Operator radiation dose at head level | 24 hours |
Not provided
Inclusion Criteria:
all patient undergoing percutaneous coronary procedures through transradial access
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Alessandro Sciahbasi, MD, PhD | Ospeadale Sandro Pertini ASL RM2 | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ospedale Sandro Pertini | Rome | Lazio | 00168 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30732471 | Derived | Sciahbasi A, Sarandrea A, Rigattieri S, Patrizi R, Cera M, Di Russo C, Zezza L, Fedele S, Ferraiuolo G. Extended Protective Shield Under Table to Reduce Operator Radiation Dose in Percutaneous Coronary Procedures. Circ Cardiovasc Interv. 2019 Feb;12(2):e007586. doi: 10.1161/CIRCINTERVENTIONS.118.007586. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| ID | Term |
|---|---|
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D014652 | Vascular Diseases |
Not provided
Not provided
Comparison of operator radiation dose at pelvic level during percutaneous coronary procedures through transradial access with or without an extension of the leaded curtain under table
Not provided
Not provided
Not provided
Not provided
| Operator pelvic dose and experimental curtain utilized | Operator radiation Dose at pelvic level comparing the two different experimental leaded curtain utilized | 24 hours |