This is a non-randomized, open label, uncontrolled first in human safety study, testing the the material used in the artificial kidney device in subjects already on hemodialysis.
Six subjects already on hemodialysis, who meet the study inclusion and exclusion criteria, and who dialyze at one of the UCSF associated hemodialysis units will be recruited. Each subject will be tested during one non hemodialysis day, at the UCSF Moffitt-Long Hospital Acute Hemodialysis Unit (AHU).
The artificial kidney engineers have created a blood flow system that can be substituted for the dialysis filter in a standard hemodialysis machine. This is NOT a dialysis filter. It allows the subjects blood to come in contact with the material while the blood is being circulated as is regularly done during a hemodialysis session.
For patient safety, the investigators will measure the following labs:
Blood tests (routine safety and frequency). CBC/platelets: q 1 hr, at HD next day ABGs, including lactate: Q 1 hr x 6 Na, K, Cl, Bicarb, BUN, Creatinine, Ca, ionized Ca, Mg, Phos: Start, end, at HD next day Liver function test: Start, end, at HD next day LDH: Start, end, at HD next day Direct Coombs' Test: Start, end, at HD next day ESR and hsCRP: Start, end, at HD next day CPK: Start, end PT/PTT: Start, end
The investigators will also be doing research blood testing:
IL-6: Start, end, at HD next day Complement: Start, end, at HD next day Haptoglobin: Start, end, at HD next day Free Hg: Start, end, at HD next day Fibrinogen, D-dimer: Start, end, at HD next day
In addition, the investigators will do material testing after each participant's test is complete.
Material studies after in vivo testing :
Cell and Protein Adhesion Studies:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| HemoCartridge | Device | Our goal is to apply MEMS (microelectromechanical systems) and nanotechnology to miniaturize the bioartificial kidney (BAK) into an implantable, self-monitoring, and self-regulating renal surrogate. The implantable BAK (iBAK) is a biocompatible cartridge containing stacks of hemofilter membranes (HemoCartridge) and renal tubule cell bioreactors (BioCartridge) combined to mimic nephron function. Here, we plan to test ONLY the material being used to construct the HemoCartridge, to be sure in humans when substituted for a standard hemodialysis filter, subjects don't develop any clinical problems or side effects during several hours of blood exposure to the material. The AK material will be engineered by the study team to allow the system to be substituted in place of a standard HD filter. |
| Measure | Description | Time Frame |
|---|---|---|
| material stability | This is a first in human safety study, testing the safety of the material used in the artificial kidney device in subjects already on hemodialysis. Specific aims include: Aim 1: To prove that blood does not degrade the material (see study description for details of processes used) 1.a. by evaluating the effect on surface roughness via scanning electron microscopy of the hemocartridge plates 1. b. by studying the effect on film thickness via scanning electron microscopy and immunohistochemistry for platelet adhesion. | 6 months |
| effects of the hemocartridge materials on inflammatory and coagulation factors in blood | Aim 2: To prove that this material is does not induce inflammatory or coagulation effects nor induce hemolysis. The investigators will do this by drawing blood before, during and after the procedure for inflammatory markers and coagulation factors. The investigators will also evaluate whether any evidence of mechanical dysfunction, such as hemolysis occurs during the treatment. See the detailed study description for the listing and timing of the tests. 1.c. evaluation of mechanical dysfunction | 6 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
ESRD
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Shuvo Roy, PhD | University of California, San Francisco | Principal Investigator |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D007676 | Kidney Failure, Chronic |
| ID | Term |
|---|---|
| D051436 | Renal Insufficiency, Chronic |
| D051437 | Renal Insufficiency |
| D007674 | Kidney Diseases |
| D014570 | Urologic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Blood testing, hemocartridge system
| D052776 |
| Female Urogenital Diseases |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
| D000091642 | Urogenital Diseases |
| D052801 | Male Urogenital Diseases |
| D002908 | Chronic Disease |
| D020969 | Disease Attributes |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |