This study is to compare transthoracic Echocardiography TTE to the gold standard Right Heart Catheterization in Terms of accuracy to measure hemodynamic parameters.
Chronic heart failure is a progressive disease in Western population. Echocardiography and right heart catheterization are important tools in the diagnosis and progress monitoring of heart failure.
Gold standard in diagnosis of hemodynamic parameters in patients with heart failure is right heart catheterization. However, this diagnostic device represents an invasive method that is additionally associated with high risks such as infections, vessel and nerve injuries. Echocardiography is probably in a position to determine hemodynamic parameters as reliably as right heart catheterization without additional health risk due to its non-invasive character. All procedures performed are part of clinical Routine. Patients do not undergo any study-specific procedure at all.
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Measurement of systolic, diastolic and mean CVP | CVP measured in mmHg | During a single right heart catheterization procedure |
| Measure | Description | Time Frame |
|---|---|---|
| Measurement of systolic, diastolic and mean PAP | PAP measured in mmHg | During a single right heart catheterization procedure |
| Measurement of systolic, diastolic and mean RVP | RVP measured in mmHg |
Not provided
Inclusion Criteria:
Exclusion Criteria:
-
Not provided
Not provided
Not provided
All patients scheduled for transthoracic echocardiography and right heart catheterization.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Herz- und Diabeteszentrum NRW | Bad Oeynhausen | North Rhine-Westphalia | 32545 | Germany |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 25242802 | Result | Fox H, Puehler T, Schulz U, Bitter T, Horstkotte D, Oldenburg O. Delayed recovery from Cheyne-Stokes respiration in heart failure after successful cardiac transplantation: a case report. Transplant Proc. 2014 Sep;46(7):2462-3. doi: 10.1016/j.transproceed.2014.06.063. | |
| 32445006 | Result | Szymczyk T, Sauzet O, Paluszkiewicz LJ, Costard-Jackle A, Potratz M, Rudolph V, Gummert JF, Fox H. Non-invasive assessment of central venous pressure in heart failure: a systematic prospective comparison of echocardiography and Swan-Ganz catheter. Int J Cardiovasc Imaging. 2020 Oct;36(10):1821-1829. doi: 10.1007/s10554-020-01889-3. Epub 2020 May 22. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| During a single right heart catheterization procedure |
| Measurement of systolic, diastolic and mean PAWP | PAWP measured in mmHg | During a single right heart catheterization procedure |
| Measurement of Cardiac Index CI | CI measured in l/M/m² | During a single right heart catheterization procedure |
| Measurement of Cardiac Output CO | CO measured in l/min | During a single right heart catheterization procedure |
| Transthoracic Echocardiography | Collected data will be analyzed for comparability | During a single TTE examination |