Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The study has 2 phases:
Measurements will be made from the forehead using the TTP's biocompatible sensor Unit that will be attached to the skin. The SU will transfer data to the MCU.
TTPâ„¢ system, which is composed of 2 parts:
The communication between the two units can be wired or wireless. The system to be used in this study is wired and the two units were connected via a Sensor Unit Cable (SCU).
The SU is attached to the temple area by a biocompatible disposable adhesive. It measures skin temperature across the temporal artery using several sensors, translates it to electrical signals and transmits those signals to the MCU. The MCU translates the electrical signals to core temperature using a special mathematical algorithm which overcomes the effect of the ambient temperature as well as the thermal properties of a specific patient. The core temperature as well as any concurrent error in the measurement process is displayed on the screen of the MCU or transmitted to the hospital VSM. The MCU has a wired connection to the hospital's VSM using Standard YSI400.
Study Objectives
The objectives of this clinical study are:
It is estimated that the study with take 18 months to complete.
Type of Study
Temperature measurements Measurements will be made from the forehead using the TTP's biocompatible sensor Unit that will be attached to the skin The SU will transfer data to the MCU. The TTPTM system will be disinfected before use an alcohol-chlorhexidine solution.
This part shall include up to 600 patients who will be monitored and analyzed during their stay in the ICU in order to get at least 30 sepsis cases.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| patients in ICU | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| TTP | Device | TTPâ„¢ allows to continuously measure body temperature using a new non-invasive method, and was cleared for marketing by US FDA (K150160) for as a temperature monitoring system intended to measure and monitor core body temperature of patients of all ages, by applying a sensor unit on the forehead. |
| Measure | Description | Time Frame |
|---|---|---|
| Continuously measure body temperature using TTP | During the trial, temperature measurements will be conducted using the TTPâ„¢ and currently used thermometers which are in routine use, later to be regarded as reference methods To examine the effectiveness of the TTPâ„¢ as a measure for detection of temperature changes pattern and to correlate such changes with fever related to infections such as sepsis. | Estimated time frame of the trial is 18 months. |
Not provided
Not provided
Study Participants - Patients hospitalized in ICU department.
Inclusion Criteria:
The Retrospective Phase
Both genders (Male or Female).
Aged 18 years and/or above.
Patients were Admitted to our ICU for more than 3 days, and shall be at least 72 hours prior to sepsis or infection detection in the ICU The Prospective Phase
Exclusion Criteria:
The patients will be excluded from the trial if one of the following occurs:
The Retrospective Phase
No exclusion criteria The Prospective Phase
- The medical staff decides that the patien t should not participate.
Unavailable measurement site in case of head injury in the head area.
Unavailable measurement reading during admission to ICU
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Vered Nehemia, MD | Contact | 02-5791921 | 846 | veredh@medisim.co.il |
| Olga Yakov, MD | Contact | 02-5791921 | 836 | olgay@medisim.co.il |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hadassah Medical Center | Jerusalem | POB 12000 | Israel |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|