Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The objective of this study is to evaluate the accuracy of four heart rate monitors in cardiac rehabilitation patients during typical, supervised cardiac rehabilitation involving exercise on a treadmill and/or stationary bicycle.
This study will assess the accuracy of four of the best-selling optical heart rate monitors when worn by cardiac rehabilitation patients.
During testing, each subject will wear:
The types of wrist-worn heart rate monitors assigned to each subject will be randomly assigned.
The location (left or right wrist) will also be randomly assigned.
Heart rate will be assessed using each of the 4 monitors with the subject on the exercise machines under each of the following conditions:
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Fit Bit Blaze | Active Comparator | Fit Bit Blaze Heart Rate Monitoring Device |
|
| Garmin Forerunner 235 | Active Comparator | Garmin Forerunner 235 Heart Rate Monitoring Device |
|
| Tom Tom Spark Cardio | Active Comparator | Tom Tom Spark Cardio Heart Rate Monitoring Device |
|
| Apple Watch | Active Comparator | Apple Watch Heart Rate Monitoring Device |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Fit Bit Blaze | Device | Fit Bit Blaze Heart Rate Monitoring Device |
|
| Measure | Description | Time Frame |
|---|---|---|
| Heart Rate Monitor Accuracy Compared to ECG | The primary outcome measure is the accuracy of each heart rate monitor compared to ECG. This will be expressed by the correlation coefficient. | 16 minutes |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Marc Gillinov, MD | The Cleveland Clinic | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Cleveland Clinic | Cleveland | Ohio | 44195 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 27732703 | Result | Wang R, Blackburn G, Desai M, Phelan D, Gillinov L, Houghtaling P, Gillinov M. Accuracy of Wrist-Worn Heart Rate Monitors. JAMA Cardiol. 2017 Jan 1;2(1):104-106. doi: 10.1001/jamacardio.2016.3340. No abstract available. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Garmin Forerunner 235 | Device | Garmin Forerunner 235 Heart Rate Monitoring Device |
|
| Tom Tom Spark Cardio | Device | Tom Tom Spark Cardio Heart Rate Monitoring Device |
|
| Apple Watch | Device | Apple Watch Heart Rate Monitoring Device |
|