Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| The First Affiliated Hospital of Xiamen University | OTHER |
Not provided
Not provided
Not provided
Not provided
In colorectal surgery, hand suturing and stapling are routine methods for performing intestinal anastomoses, and these methods appear to be similar in terms of clinical safety. Despite several years of experience with surgical procedures as well as improvements to the medical devices, problems with disturbed anastomotic healing leading to leakage and stenosis after colorectal surgery remain a significant challenge for surgeons. In addition, preoperative radiotherapy has been shown to increase the risk of anastomotic leakage even further.
The methods that are used today to detect leakages are unfortunately inaccurately and limited to monitoring symptoms, temperature, CRP (C-reactive protein)-levels, and performing abdominal examinations and CT-scans. These clinical signs and parameters usually become apparent several days after onset of the leakage, which leads to a delayed diagnosis. Anastomotic leakage is not only a significant cause of increased morbidity of complications and mortality in patients, but also associated with increased risk of local recurrence and poor prognosis. Moreover, when reoperation is required to fix the leakage, a permanent stoma may be made at the level of the sigmoid colon and this procedure impacts quality of life negatively.
Based on the above considerations, a novel, adaptive anastomotic method has been developed by CarpoNovum to achieve a safer anastomosis. The method's working name is C-REX Ring-locking Procedure (C-REX is referred to our Colorectal anastomotic rings for Re-join the intestinal ends and validate the anastomosis, with function of Extract samples for analysis and conduct X-ray through connected catheters).
The novel adaptive anastomotic medical devices, C-REX LapAid and C-REX DMH/DMHC are easy to use, with unique possibility to control the anastomosis during and after surgery. The previous successful preclinical study encourages a clinical verification in patients undergoing colonic resection to evaluate the safety and performance of C-REX Ring-locking Procedure by use of C-REX LapAid and C-REX DMH/DMHC.
OVERALL DESIGN The study is a prospective, multicenter, single arm study Possible study candidates are patients requiring resection of the left colon (descending colon and sigmoid) or the upper rectum (15cm above the anal rim) due to malign or benign disease. After physical examination, checking of inclusion/exclusion criteria, and after informed consent has been achieved, potential subjects will be enrolled in the study, and the investigational surgery will be performed during hospitalization. The devices, i.e. C-REX LapAid and C-REX DMH/DMHC (dual male handle/dual male catheter handle), included in C-REX Ring-locking Procedure are applied to the inside of the intestine and connected to catheters that allow monitoring of the anastomosis (if DMC is applied).
The healing period is expected to be approximately 10 ± 2 days. The short-term implant, i.e. the anastomotic ring, detaches via necrosis on the inner part of the intestinal surface and is expelled the natural way during hospitalization.
The subject can be discharged from the hospital when the short-term implant has been evacuated, and the subject has begun to eat and has normal bowel movements. The observation period lasts until 30 days after surgery. The subject then continues follow-up according to local routine.
QUALITY CONTROL Authorization to perform C-REX Ring-locking Procedure According to CarpoNovum's regulation (Document 0041: Procedure, Accreditation of Surgeons for Clinical Studies), clinical investigators must be authorized to conduct the C-REX Ring-locking Procedure with C-REX LapAid and C-REX DMH/DMHC by performing at least one surgery on pigs and at least one train-in surgery on patients with the person in charge of the study (Dr. Anders Grönberg). When the clinical investigator is authorized to perform the C-REX Ring-locking Procedure with C-REX LapAid System, he or she receives a certificate. This certificate could also admit the clinical investigator the right to authorize other surgeons to perform C-REX Ring-locking Procedure with C-REX LapAid and C-REX DMH/DMHC (i.e. to perform at least one operations on pigs and at least one train-in operations on patients with the authorized clinical investigator).
Monitoring To ensure that the study is appropriately conducted, a monitor appointed by the sponsor will visit the investigation site regularly and oversee the investigator's compliance with the CIP, perform source-data verification and report to the sponsor on the progress of the study.
Each investigation site and clinical investigator in the study will be monitored. On all occasions, the responsible monitor and/or the person in charge of the study will secure for example that:
The responsible monitor will write a report after each visit to the medical institutions. The reports will be sent to the sponsor and the principal clinical investigators.
Documentation and data processing Medical record of subjects
The following information should be clearly documented in medical record of subjects:
Document and data control Prior to commencement of the study, clinical investigators and their staff will be informed about CIP, CRFs and other study documents and procedures.
For each subject enrolled, regardless of medical device initiation, a CRF must be completed and signed by corresponding investigation personnel. This applies to those subjects who fail to complete the study. If a subject withdraws from the study, the reason must be noted on CRF.
Data and information of subjects derived from the study are considered as source data. To ensure that all data are complete and correct, source data verification (SDV) will be confirmed by the monitor.
Comments in CRF should be made with a ballpoint pen with permanent ink. If comments are missing in CRF, reasons for this must be stated. No questions, squares, fields or similar should be left without comments.
CRF entries and corrections will only be performed by investigational personnel, authorized by the principle clinical investigator. Errors should be crossed out but not obliterated, the correction inserted, and the change initialed and dated by the clinical investigator.
Then entries will be checked by the monitor and any errors or inconsistencies will be checked and corrected immediately.
The responsible clinical investigator is obliged to keep the subject identification lists with the subject's identification code and identity in a safe place at the investigation site (hospital), accessible only to the investigation personnel. These source data and subject identification lists will be saved for 10 years after the close of the study at the medical institution.
NUMBER OF SUBJECTS The aim of this study is to verify the novel device in clinical practise and for CE (Conformité Européenne) marking later. Since no control group is included, there is no need for power determinations.
Considering that similar anastomotic devices have been used in clinic for decades, 20 subjects will be included in The First Affiliated Hospital of Xiamen University.
STATISTICAL ANALYSIS OF VARIABLES Descriptive methods are used to analyze the data collected in the study. The incidences of anastomotic leakage and other AEs/device deficiencies are calculated.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| C-REX group | Experimental | After resection of the disease in colon, the intestinal ends will be anastomosed by the investigational device, i.e. C-REX LapAid and C-REX DMH/DMHC included in the C-REX Ring-locking Procedure. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| C-REX Ring-locking Procedure | Device | The C-REX Ring-locking Procedure is a method based on adaptive anastomosis, in which intestinal ends adapt to each other after resection due to tumor, injury, or other disease. The investigational devices comprised of two components, i.e. C-REX LapAid and C-REX DMH/DMHC |
| Measure | Description | Time Frame |
|---|---|---|
| Time to evacuation of the short-term implant | The subject informs the clinical investigator and hand over the expelled short-term implant | About 2 weeks after surgery |
| Measure | Description | Time Frame |
|---|---|---|
| Time to first intestinal sounds | The subject informs the clinical investigator about when the intestine begin to murmur, and the clinical investigator will check the sound with a stethoscope. | Up to 30 days after surgery |
| Time to first passage of gas |
| Measure | Description | Time Frame |
|---|---|---|
| Hemoglobin | Blood tests to detect potential anastomotic leakage. | Up to 30 days after surgery, when needed |
| WBC (white blood cell) | Blood tests to detect potential anastomotic leakage. |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Qi Luo | The First Affiliated Hospital of Xiamen University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| The First Affiliated Hospital of Xiamen University | Xiamen | Fujian | 361003 | China |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003110 | Colonic Neoplasms |
| D003111 | Colonic Polyps |
| ID | Term |
|---|---|
| D015179 | Colorectal Neoplasms |
| D007414 | Intestinal Neoplasms |
| D005770 | Gastrointestinal Neoplasms |
| D004067 | Digestive System Neoplasms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
The subject informs the clinical investigator when it occurs.
| Up to 30 days after surgery |
| Time to first defecation | The subject informs the clinical investigator when it occurs. | Up to 30 days after surgery |
| Number of postoperative interventions related to the device | The clinical investigator notes the interventions after surgery related to the use of device, for instance, CT scan, endoscopy examination and re-operation etc. | Up to 30 days after surgery |
| Integrity pressure | To confirm that the two anastomotic rings are properly locked to each other, measure integrity pressure through catheters connected to DMC (if DMC is applied). By infusing air into the closed space adjacent to the anastomosis via on catheter and concomitantly camping the other three catheters. When the pressure in the closed space exceeds the contact-induced closure by the joined intestinal segments, the pressure abruptly dropped and is defined as integrity pressure. | The operation day |
| Post-operative X-ray examination | The anastomosis could be examined through catheters connected to DMC (if DMC is applied) in case of suspect of anastomotic leakage. The integrity of anastomosis is examined by local infusion of water-soluble contract media through one of the catheters, and at the same time conduct X-ray examination. The contract media will leak from the closed space adjacent to the anastomosis if there is a anastomotic leakage. | Up to 4 days after surgery |
| Time of surgery | The time to complete the operation. | The operation day |
| Up to 30 days after surgery, when needed |
| Physical examination | Body temperature, palpation of abdomen etc. | Up to 30 days after surgery |
| Procedures and/or device related adverse events | The clinical investigator notes the adverse events, severity and the relation to the investigational device. | Up to 30 days after surgery |
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D004066 | Digestive System Diseases |
| D005767 | Gastrointestinal Diseases |
| D003108 | Colonic Diseases |
| D007410 | Intestinal Diseases |
| D007417 | Intestinal Polyps |
| D011127 | Polyps |
| D020763 | Pathological Conditions, Anatomical |
| D013568 | Pathological Conditions, Signs and Symptoms |