The purpose of the study is to measure patient- temperature in the perioperative period of patients undergoing plastic surgery in an ambulatory surgical unit. This study will evaluate if active warming with self-warming blanket (Easywarm®) is as effective as active warming with forced-air blanket (BairHugger®). Second the study will evaluate if one or both methods is effective in preventing perioperative hypothermia.
Background:
Anesthesia medicaments given in general anesthesia cause impaired thermoregulation and thermogenesis. After induction of general anesthesia the core temperature is reduced to redistribution of blood from the body core to the cooler skin. Later impaired thermogenesis contributes to further loss of heat.
Mild hypothermia (<36 degrees Celsius) contributes to increased incidence of wound infections, prolonged stay in the post anesthesia care unit, shivering and reduced patient comfort.
There are several effective interventions to prevent hypothermia such as active warming pre-, per- and postoperatively. Preheated intravenous fluids and medical interventions to alter the blood distribution from the periphery to the body core have been effective in preventing hypothermia.
In the department both self-warming blanket (Easywarm®) and forced-air blanket (BairHugger®) are routinely used to prevent hypothermia. It has been observed that a few patients undergoing plastic surgery with anesthesia time more than one hour are shivering and feeling cold in the postoperative period.
Purpose:
The purpose of the study is to observe and measure patient- temperature in the perioperative period of patients undergoing plastic surgery in an ambulatory surgical unit. This study will evaluate if active warming with self-warming blanket (Easywarm®) is as effective as active warming with forced-air blanket (BairHugger®). Second the study will evaluate if one or both methods is effective in preventing perioperative hypothermia.
Design:
The is a quality assurance study deigned as a prospective randomised trial. With a validated non-invasive termometer (SpotOn® 3M) temperature is measured before, during and after surgical procedures in general anesthesia. An equal number of notes with the number 1 and 2 were put into an envelope (1=EasyWarm®, 2=BairHugger®). For each operation theater a note is drawn, and all patients in that operation theater receives active warming according to the number on the note.
Population data:
Sex, age , weight, height, BMI, medication, morbidities and ASA class will be registered.
Measurements:
Other registrations:
Data is collected and registered on a dataform. Data are analysed in a anonymized excel workbook.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Easywarm | Self warming blanket to prevent perioperative hypothermia |
| |
| BairHugger | Forced-air warming blanket to prevent perioperative hypothermia |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Easywarm | Device | Warming blanket |
| |
| BairHugger |
| Measure | Description | Time Frame |
|---|---|---|
| Temperature | Temperature Celsius measured by SpotOn 3M | Perioperative period |
| Measure | Description | Time Frame |
|---|---|---|
| Medication given during study period | Type and dosage is registered. Ephedrine and phenylephrine are known to interact with temperature regulation. | Perioperative period |
| Temperature Numerical Rating Scale |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients planned for plastic surgery with planned total anestesia for more than 60 minutes are enrolled consecutively.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Stig S Tyvold, MD PhD | Aleris Helse AS | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Aleris Solsiden | Trondheim | Sør-Trøndelag | 7014 | Norway |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31567576 | Derived | Tyvold SS. Preventing hypothermia in outpatient plastic surgery by self-warming or forced-air-warming blanket: A randomised controlled trial. Eur J Anaesthesiol. 2019 Nov;36(11):843-850. doi: 10.1097/EJA.0000000000001087. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D011183 | Postoperative Complications |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
Patient warming mattress with continuous warm air. |
|
To identify at which temperature the patient is comfortably warm without need for warming intervention.
| Perioperative period. |