The Accuro is a three dimensional handheld ultrasound device. This device uses sound waves to create pictures of the spine in three dimensions. This may allow the physician to view the spine in more detail for procedures such as spinal anesthesia and other diagnostic procedures.
We aim to assess the benefit of using both the Accuro and traditional landmark palpation technique to determine accurate spinal level in women who undergo cesarean section. This study will also assess provider preference for use of both Accuro and palpation compared with palpation alone or use of Accuro alone.
Anesthesia Providers will first identify the L4/L5 space using the traditional technique of palpating the iliac crests to estimate spinal level, which will be marked with a single dot from a marking pen. The provider will then use the Accuro 3000 to identify the L4/L5 interspace.
Results will be compared to results obtained in IRB 18070 "Handheld 3D lumbar spine navigation: A clinical validation study RM002" where subjects who were undergoing a C-section were randomized to either palpation or Accuro alone.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Palpation and Accuro | Experimental | The placement site for the spinal anesthesia will be identified using both palpation and Accuro. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Palpation and Accuro | Device | Identify placement for spinal |
|
| Measure | Description | Time Frame |
|---|---|---|
| success rates | Success rates: defined as successful spinal administration on the first needle insertion attempt. | Day 1 |
| Measure | Description | Time Frame |
|---|---|---|
| Level of spinal placement: a record of the vertebral level where the spinal is administered. | Level of spinal placement: a record of the vertebral level where the spinal is administered. | Day 1 |
Not provided
Inclusion Criteria:
• Patients between the ages of 18 and 45 presenting for a C-section delivery or scheduled for elective Cesarean section
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mohamed Tiouririne, MD | University of Virginia | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Virginia Health System | Charlottesville | Virginia | 22908 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 21572316 | Background | Chin KJ, Perlas A, Chan V, Brown-Shreves D, Koshkin A, Vaishnav V. Ultrasound imaging facilitates spinal anesthesia in adults with difficult surface anatomic landmarks. Anesthesiology. 2011 Jul;115(1):94-101. doi: 10.1097/ALN.0b013e31821a8ad4. | |
| 20696564 | Background | Vallejo MC, Phelps AL, Singh S, Orebaugh SL, Sah N. Ultrasound decreases the failed labor epidural rate in resident trainees. Int J Obstet Anesth. 2010 Oct;19(4):373-8. doi: 10.1016/j.ijoa.2010.04.002. Epub 2010 Aug 8. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| May 3, 2022 | Jun 1, 2022 | 2 |
| ID | Term |
|---|---|
| D010173 | Palpation |
| ID | Term |
|---|---|
| D010808 | Physical Examination |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 11421838 | Background | Grau T, Leipold RW, Conradi R, Martin E. Ultrasound control for presumed difficult epidural puncture. Acta Anaesthesiol Scand. 2001 Jul;45(6):766-71. doi: 10.1034/j.1399-6576.2001.045006766.x. |
| 14656785 | Background | Grau T, Bartusseck E, Conradi R, Martin E, Motsch J. Ultrasound imaging improves learning curves in obstetric epidural anesthesia: a preliminary study. Can J Anaesth. 2003 Dec;50(10):1047-50. doi: 10.1007/BF03018371. |
| 21422997 | Background | Chin KJ, Karmakar MK, Peng P. Ultrasonography of the adult thoracic and lumbar spine for central neuraxial blockade. Anesthesiology. 2011 Jun;114(6):1459-85. doi: 10.1097/ALN.0b013e318210f9f8. |
| Background | Karmakar MK. Ultrasound for central neuroaxial blocks. Techniques in regional anesthesia and pain management 2009;13:161-70. |