The objective of the clinical investigation is to test whether intra-operative traction force feed back during vacuum extraction leads to a significant decrease in incidence of brain damage in neonates.
By randomization, half of the vacuum extraction patients will be assigned to delivery using a new intelligent handle for vacuum extractions, and half will be assigned to conventional method without traction force measurement.
The most common indications for vacuum extraction are dystocia and/or fetal asphyxia. The safety of assisted vaginal delivery with vacuum extraction has been discussed since its introduction almost fifty years ago. Serious complications such as asphyxia, intracranial hemorrhage and seizures are overrepresented at vacuum extraction compared to spontaneous vaginal delivery.
Little has been done to improve the procedure since the introduction. Safety measures recommended include restricting total time and number of pulls, a full 34 week gestation, and station of the head at the spines or below. A general advice is also to avoid excessive traction force. There is no general agreement to what a safe traction force might be. With exceeding force there seems to be an increased risk for rupture of the sagittal sinus and tearing of the falx at its attachment to the tentorium. Furthermore, when the fetal head is becoming exceedingly elongated and flattened, and as the cup pops off it might cause damage to the brain and blood vessels.
During the procedure the obstetrician is under significant stress and the subjective element of the evaluation of traction force is a concern. The difficult decision of whether to continue a heavy extraction or abort the operation is made under stressful conditions and based mostly on subjective impressions.
To provide the obstetrician with more objective information, the investigators developed a new device consisting of an intelligent handle hooked to the chain of a regular metal cup.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Vacuum extraction intelligent system | Experimental | Measurement and intra-operative feed back of vacuum extraction data: notification signal based an algorithm calculation using traction force (peak and time force integral) and time. |
|
| conventional | No Intervention | conventional handle |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Vacuum extraction intelligent system | Device | Vacuum extraction intelligent system - this is the intervention |
|
| Measure | Description | Time Frame |
|---|---|---|
| Composite neonatal brain damage | Composite consists of: Hypoxic ischemic encephalopathy (HIE), intracranial hemorrhage (ICH), seizures, perinatal mortality and subgaleal hematoma as routinely diagnosed in patient chart | From start of extraction through 28 days after delivery (or until discharge from the hospital) |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Magnus Westgren, Professor | Karolinska Institutet | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Karolinska University Hospital | Stockholm | 14186 | Sweden |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 13497632 | Background | MALMSTROM T. The vacuum extractor, an obstetrical instrument. I. Acta Obstet Gynecol Scand Suppl. 1957;36(suppl 3):5-50. No abstract available. | |
| 471369 | Background | Moolgaoker AS, Ahamed SO, Payne PR. A comparison of different methods of instrumental delivery based on electronic measurements of compression and traction. Obstet Gynecol. 1979 Sep;54(3):299-309. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D020925 | Hypoxia-Ischemia, Brain |
| ID | Term |
|---|---|
| D002545 | Brain Ischemia |
| D002561 | Cerebrovascular Disorders |
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 17762410 | Background | Towner DR, Ciotti MC. Operative vaginal delivery: a cause of birth injury or is it? Clin Obstet Gynecol. 2007 Sep;50(3):563-81. doi: 10.1097/GRF.0b013e31811eaa39. |
| 15031028 | Background | Whitby EH, Griffiths PD, Rutter S, Smith MF, Sprigg A, Ohadike P, Davies NP, Rigby AS, Paley MN. Frequency and natural history of subdural haemorrhages in babies and relation to obstetric factors. Lancet. 2004 Mar 13;363(9412):846-51. doi: 10.1016/S0140-6736(04)15730-9. |
| 25558833 | Result | Pettersson K, Ajne J, Yousaf K, Sturm D, Westgren M, Ajne G. Traction force during vacuum extraction: a prospective observational study. BJOG. 2015 Dec;122(13):1809-16. doi: 10.1111/1471-0528.13222. Epub 2015 Jan 5. |
| 33637058 | Derived | Romero S, Pettersson K, Yousaf K, Westgren M, Ajne G. Perinatal outcome after vacuum assisted delivery with digital feedback on traction force; a randomised controlled study. BMC Pregnancy Childbirth. 2021 Feb 26;21(1):165. doi: 10.1186/s12884-021-03604-z. |
| D009422 | Nervous System Diseases |
| D002534 | Hypoxia, Brain |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D000860 | Hypoxia |
| D012818 | Signs and Symptoms, Respiratory |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |