An observational comparison of different locations of saturation measurements during Flexible Bronchoscopy
The study group will include 100 patients undergoing flexible fiberoptic bronchoscopy (FFB).
The patients will receive sedation with Midazolam, Fentanyl and Propofol. All patients will receive supplemental oxygen via nasal cannula (2-4 L/min) before the beginning of the procedure.
In all cases, patients will be monitored using continuous electrocardiography, pulse oximetry (on patients finger), and transcutaneous carbon dioxide and saturation (on patients earlobe), and automated noninvasive blood pressure recordings every 5 minutes. All parameters will be recorded from accepting patient to bed of procedure until 10 minutes after removal of FFB from nasopharynx.
The saturation will be measured in 3 different locations (one pulse is added in other earlobe). additionally, A blood gas sample will be taken during discrepancy between different measurements.
Immediately after the end of procedure, the measurements from 3 different monitors will be printed, and the blood sample be taken to a gas sample machine by the investigator.
Desaturation value and time will be compared between the different locations. The blood arterial saturation will be compared to other measurements taken at the same time.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| blood gas sampling | Diagnostic Test |
| Measure | Description | Time Frame |
|---|---|---|
| Value changes between locations | Difference of 10% of blood saturation between different locations during sedation for bronchoscopy procedure. | Through completion of bronchoscopy procedure an average of 30 minutes |
| Time changes between locations | The level of desaturation of 90% is checked in the different monitors and the gap in seconds is registered | Through completion of bronchoscopy procedure an average of 30 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| gap between arterial gas sample and different monitors | during differences of more than 5% between finger and earlobe monitors we will take an arterial blood sample and the lab result will be compared to the measurements at the same time | Through completion of bronchoscopy procedure an average of 30 minutes |
Not provided
Inclusion Criteria:
Exclusion Criteria:
-
Not provided
Not provided
Not provided
100 patients, adults, undergoing Flexible Fiberoptic Bronchoscopy under sedation
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mordechai R Kramer, MD | Rabin Medical Center, Belinson Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Pulmonary Institute Rabin Medical Center | Petah Tikva | 49100 | Israel |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D008171 | Lung Diseases |
| ID | Term |
|---|---|
| D012140 | Respiratory Tract Diseases |
Not provided