This prospective study will randomize 1:1 people living with multiple sclerosis-associated fatigue to one of two spectra of light therapy. Each participant will be asked to use the light box twice daily at home or at the workplace at preset hours during the day for a total of four weeks. Participants will be asked to record their fatigue on standard measurement scales before, during, and after the use of the light therapy box. The investigators anticipate a reduction in self-reported fatigue following the use of the light box therapy of a particular spectrum of light among people living with multiple sclerosis.
Study Protocol:
Eligible participants will be consented and randomized 1:1 to (a) white LT (10,000 lux), or (b) dim red LT (<300 lux). Participants will be informed that this study will examine the effect of two different light spectra on fatigue. The following assessments will be administered by the study principal investigator at the baseline visit: (1) the Kurtzke Extended Disability Status Scale (EDSS), (2) FSS, (3) Beck Depression Inventory II (BDI), (4) Pittsburgh Sleep Quality Index (PSQI), (5) Berlin questionnaire for obstructive sleep apnea, (6) Epworth Sleepiness Scale. A two-week sleep diary will be collected before enrollment in order to screen for significant behavioral insufficient sleep or circadian rhythm disorders. The light box used for LT is designed to stand on a desk or tabletop. It can be used in the home or office. The light is delivered at a downward angle to maximize the effectiveness. The box runs on 124 watts and contains full spectrum 5000k 10,000 lux bulbs. Bright light treatment requires at least 2,500 lux to be effective.
Data Collection:
The study period will include a two-week baseline period, a four-week treatment period, and a four-week follow up period. Throughout the study period, participants will record their fatigue using the Visual Analogue Fatigue Scale (VAFS) four times daily, starting after waking up, and every four hours thereafter. The VAFS is a simple, validated 10-point scale ranging from 1 to 10 in which participants can report their fatigue as a snapshot at that particular moment. Data collection will occur by participants in self-report fashion. A FSS score will be collected at enrollment as well as at the end of the four week treatment period and the end of the four week follow-up period. There will be three visits with a principal investigators (PI), including the baseline visit described above, a visit with the PI at the end of the treatment period in which participants will report a FSS and discuss their experiences with LT, and a third follow-up visit at the end of the four-week follow up period for a final FSS. At this last visit they will be queried on whether they believe the intervention had any effect on their fatigue and whether they believe the alternative therapy (white light or dim red light) would have been more or less beneficial. Additionally participants will be asked to keep a LT log in which they will record daily LT exposure and associated side effects.
Statistical Analysis:
The primary outcome measure is the change in the average FSS after the four-week study period in the bright light "active" vs. dim light "control" groups. There are no reports on FSS in response to bright LT in pMS. Using the conventional values of α=0.05 and β=0.80 for 2-tailed tests of probability with equally sized groups: a difference in 10 points on FSS between groups requires 18 people per study arm; a difference in 8 points requires 28 people per group. If power is reduced to 70%, the sample sizes are 22 and 14 for 8-point and 10-point differences. First, the investigators will compare the mean change in FSS scores, from baseline to after completion of LT, in an intention to treat analysis. The secondary outcome measure will be a change in the global VAFS scores after light therapy in both groups. Frequencies will be used to describe baseline characteristics across treatment arms. X2 statistics or Fisher's exact test will be used to compare the differences between groups. VAFS will be evaluated using a mixed-effects model which accounts for correlation between repeated measurements. Participant logbooks will be used to generate summary statistics and graphically display fatigue patterns throughout the day. Logbooks will also qualitatively assess the safety and tolerability of LT.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Light Therapy-Spectrum 1 | Active Comparator | Light from 'active' spectrum |
|
| Light Therapy-Spectrum 2 | Placebo Comparator | Light from 'placebo' spectrum |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Light Therapy box | Device | The light box used for LT (SunRay by The Sunbox Company, Gaithersburg, Maryland, USA) is approximately 15.5" tall x 23" wide x 3.25" deep and is designed to stand on a desk or tabletop. It can be used both in the home or office. The light is delivered at a downward angle to maximize the effectiveness. The box runs on 124 watts and contains full spectrum 5000k 10,000 lux bulbs. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Average Fatigue Severity Scale (FSS) Score | Measure of general level of fatigue. Range: 9 to 63. Lower scores indicate less reported fatigue. | 4 weeks |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Massachusetts General Hospital | Boston | Massachusetts | 02114 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Light Therapy-Spectrum 1 | Light from 'active' spectrum Light Therapy box: The light box used for LT (SunRay by The Sunbox Company, Gaithersburg, Maryland, USA) is approximately 15.5" tall x 23" wide x 3.25" deep and is designed to stand on a desk or tabletop. It can be used both in the home or office. The light is delivered at a downward angle to maximize the effectiveness. The box runs on 124 watts and contains full spectrum 5000k 10,000 lux bulbs. |
| FG001 | Light Therapy-Spectrum 2 | Light from 'placebo' spectrum Light Therapy box: The light box used for LT (SunRay by The Sunbox Company, Gaithersburg, Maryland, USA) is approximately 15.5" tall x 23" wide x 3.25" deep and is designed to stand on a desk or tabletop. It can be used both in the home or office. The light is delivered at a downward angle to maximize the effectiveness. The box runs on 124 watts and contains full spectrum 5000k 10,000 lux bulbs. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Light Therapy-Spectrum 1 | Light from 'active' spectrum Light Therapy box: The light box used for LT (SunRay by The Sunbox Company, Gaithersburg, Maryland, USA) is approximately 15.5" tall x 23" wide x 3.25" deep and is designed to stand on a desk or tabletop. It can be used both in the home or office. The light is delivered at a downward angle to maximize the effectiveness. The box runs on 124 watts and contains full spectrum 5000k 10,000 lux bulbs. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Row population is equal to overall population. |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Change in Average Fatigue Severity Scale (FSS) Score | Measure of general level of fatigue. Range: 9 to 63. Lower scores indicate less reported fatigue. | 4 participants were withdrawn from the study before providing outcome data. | Posted | Mean | Standard Deviation | score on a scale | 4 weeks |
|
Adverse event data was collected over 4 weeks of light therapy, with collection at 2 and 4 weeks after starting light therapy.
4 participants were withdrawn from the study prior to collection of adverse event data.
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Light Therapy-Spectrum 1 | Light from 'active' spectrum Light Therapy box: The light box used for LT (SunRay by The Sunbox Company, Gaithersburg, Maryland, USA) is approximately 15.5" tall x 23" wide x 3.25" deep and is designed to stand on a desk or tabletop. It can be used both in the home or office. The light is delivered at a downward angle to maximize the effectiveness. The box runs on 124 watts and contains full spectrum 5000k 10,000 lux bulbs. |
Not provided
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Headache | Nervous system disorders | Non-systematic Assessment |
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Farrah J. Mateen, MD, PhD, Associate Professor of Neurology | Massachusetts General Hospital | 617-724-8653 | fmateen@mgh.harvard.edu |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Aug 8, 2018 | Apr 13, 2020 | Prot_SAP_000.pdf |
Not provided
| ID | Term |
|---|---|
| D020529 | Multiple Sclerosis, Relapsing-Remitting |
| D009103 | Multiple Sclerosis |
| D005221 | Fatigue |
| ID | Term |
|---|---|
| D020278 | Demyelinating Autoimmune Diseases, CNS |
| D020274 | Autoimmune Diseases of the Nervous System |
| D009422 | Nervous System Diseases |
| D003711 | Demyelinating Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| BG001 | Light Therapy-Spectrum 2 | Light from 'placebo' spectrum Light Therapy box: The light box used for LT (SunRay by The Sunbox Company, Gaithersburg, Maryland, USA) is approximately 15.5" tall x 23" wide x 3.25" deep and is designed to stand on a desk or tabletop. It can be used both in the home or office. The light is delivered at a downward angle to maximize the effectiveness. The box runs on 124 watts and contains full spectrum 5000k 10,000 lux bulbs. |
| BG002 | Total | Total of all reporting groups |
| Count of Participants |
| Participants |
|
| Age, Continuous | Mean | Full Range | years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| Years since first diagnosis | Mean | Full Range | years |
|
| Expanded Disability Status Scale Score | Scale of disability in MS. Range: 0 (normal neurological exam) to 10 (death due to MS). Lower scores indicate less disability. | Mean | Full Range | units on a scale |
|
| Type of Multiple Sclerosis | Count of Participants | Participants |
|
| Light Therapy-Spectrum 2 |
Light from 'placebo' spectrum Light Therapy box: The light box used for LT (SunRay by The Sunbox Company, Gaithersburg, Maryland, USA) is approximately 15.5" tall x 23" wide x 3.25" deep and is designed to stand on a desk or tabletop. It can be used both in the home or office. The light is delivered at a downward angle to maximize the effectiveness. The box runs on 124 watts and contains full spectrum 5000k 10,000 lux bulbs. |
|
|
| 0 |
| 17 |
| 0 |
| 17 |
| 15 |
| 17 |
| EG001 | Light Therapy-Spectrum 2 | Light from 'placebo' spectrum Light Therapy box: The light box used for LT (SunRay by The Sunbox Company, Gaithersburg, Maryland, USA) is approximately 15.5" tall x 23" wide x 3.25" deep and is designed to stand on a desk or tabletop. It can be used both in the home or office. The light is delivered at a downward angle to maximize the effectiveness. The box runs on 124 watts and contains full spectrum 5000k 10,000 lux bulbs. | 0 | 14 | 0 | 14 | 3 | 14 |
| Difficulty Sleeping | General disorders | Non-systematic Assessment |
|
| Eye issues | Eye disorders | Non-systematic Assessment | Eye strain, difficulty with night vision, and tearing issues |
|
| Dizziness | General disorders | Non-systematic Assessment |
|
| Fatigue | General disorders | Non-systematic Assessment |
|
| Hot flash | General disorders | Non-systematic Assessment |
|
Not provided
Not provided
| D001327 | Autoimmune Diseases |
| D007154 | Immune System Diseases |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |