Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The aim of this study was to evaluate the efficacy and safety to use external haemostatic between Axiostat® (Chitosan haemostatic dressing) and conventional cotton gauze dressing as a pre hospital acute hemorrhagic control in trauma in ambulance settings.
Abstract:
Accidents and trauma comprise leading causes of death and disability throughout the world. In developing countries such as India, where emergency trauma care is still in its infancy, it accounts for almost 10% deaths every year. Lack of adequate pre-hospital care and uncontrolled bleeding from wound site are stated to be the prominent reasons for such deaths.
In this study, a novel chitosan-based haemostatic dressing (Axiostat®, Axio Biosolutions, India) was investigated as an initial hemorrhage controlling device in pre-hospital scenario. The study was conducted with the help of 35 Emergency Medical Technicians (EMTs).
A total of 133 patients with scalp wound injury were identified for the study, of which 104 patients meeting the selection criteria were included in the study. The selected patients were randomly assigned into two groups, the test group consisting of 47 subjects received Axiostat® treatment; whereas, 57 subjects in the control group were treated with a conventional cotton-gauze dressing. All subjects needed suturing as the subjects included in the study were brought with open scalp wounds.
The Axiostat® showed a superior efficacy in controlling bleeding in comparison to the cotton gauze. The average time for haemostasis with cotton gauze dressing was about 18.56 ± 5.04 minutes; while with Axiostat® haemostasis was achieved in less than 5 minutes (4.68 ± 1.04 min).
On analyzing this study, it was evident that Axiostat® dressing enables early haemostasis which prevents much blood loss and the wound becomes very clean on removal of dressing for later wound suturing when compared to normal cotton gauze.
These findings demonstrated the potential of Axiostat® as a first-line intervention in controlling acute hemorrhage in the pre-hospital scenarios.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Axiostat® Size | Experimental | Device: Axiostat® Size: 8 x 5 cm Axiostat® is a sterile, non-absorbable haemostatic dressing intended to control profuse bleeding within minutes of application by providing an active mechanical barrier to the wound site. Mechanism of action is such that Axiostat® is an extremely positive dressing that becomes very sticky in the presence of negatively charged blood and thus seals the wound area. |
|
| Cotton Gauze | Active Comparator | Cotton Gauze Size: 8 x 5 cm |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Axiostat® | Device |
|
| |
| Cotton Gauze |
| Measure | Description | Time Frame |
|---|---|---|
| Time to achieve hemostasis | Time to achieve hemostasis by observing the time at which blood oozing through or from periphery of the dressing stops. | 1 Day |
| Measure | Description | Time Frame |
|---|---|---|
| Number of patients with rebleeding | Number of patients with rebleeding will be counted (unit of measurement is number/count of patients) | 1 Day |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Dr. Mohmmad Kabeer | Malabar Institute of Medical Sciences | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Malabar Insitute of Medical Sciences | Calicut | Kerala | 673016 | India |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006470 | Hemorrhage |
| D014947 | Wounds and Injuries |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
|