The purpose of this study is to evaluate the effect of printing layer thickness on accuracy of computer aided surgical guide
Computer aided surgical guide has many variables that affect its accuracy , in this study one variable is considered that may affect the accuracy of surgical guide which is printing of layer thickness of surgical guide whether 50 micron or 100 micron.
computer aided surgical guide is constructed by imaging the patient pre-operative cone beam CT wearing scan appliance , then virtual implant placement on special soft ware ( Blue sky Bio ) and optical scanning of patient casts , afterword superimposition of the virtual implants on the scanned casts to design the surgical guide and printing on 3D printer ( Zenith 3D printer , Dentis , Korea ) with printing layer thickness 50 micron in first group and 100 micron in second group . Fixation of surgical guide in patient mouth and drilling of implant osteotomy through the guiding sleeves , post-operative Cone Beam CT with the same apparatus and setting as pre-operative scan .
Finally, the pre-operative and post operative scans were then overlapped to measure linear and angular deviation of the virtually planned and actual implants position.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 50 micron | Experimental | surgical guide constructed with 3D printing with printing layer thickness 50 micron |
|
| 100 micron | Active Comparator | surgical guide constructed with 3D printing with printing layer thickness 100 micron |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| computer aided surgical guide | Device | comparing accuracy of surgical guide of printing layer thickness of 50 micron and 100 micron by superimposition of pre-operative and post-operative CBCT |
| Measure | Description | Time Frame |
|---|---|---|
| accuracy of surgical guide | 6 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Amr M Hanafy, master | Contact | 01111228022 | amrhanafy201055@yahoo.com | |
| Amr H El-Khadem, phd | Contact | 01001162401 | amrelkhadem@gmail.com |
| Name | Affiliation | Role |
|---|---|---|
| Mahmoud El far, phd | Cairo University | Study Director |