The Prosthesis-to-Annulus Relation I (PAR I) trial is a German multicenter study assessing the relation between the prosthetic GOA and the area of LVOT as potentially new parameter for the prediction of hemodynamic outcome. The results may possibly guide future valve size selection an may allow prediction of functionally relevant PPM (Patient-Prosthesis-Mismatch)
Great debates revolve around the hemodynamic performance of prosthetic tissue valves. It is influenced by the design and the specific sizing strategy. Design determines the actual geometric orifice area (GOA), sizing strategy the actual size of the selected valve. Currently, hemodynamic performance is generally assessed by determining the effective orifice area (EOA, derived from the continuity equation by relating flow velocities and LVOT area). The question whether a prosthesis patient mismatch (PPM) is present is then addressed by relating EOA to body surface area (EOAi). However, this relation may not be reasonable because EOAi relates flow velocity twice to patient-specific anatomic parameters (LVOT area and body surface area) . Considering this potential methodological flaw, debate and confusion regarding PPM is easily understood, despite the fact that, intuitively leaving a gradient behind after aortic valve replacement cannot be irrelevant. Thus a reliable and comparable method to determine the presence of PPM is needed. In PAR I Trial the relation between true prothetic GOA and LVOT area will be assesses as a potentially new parameter for prediction of hemodynamic outcome, to possibly guide future valve size selection (inclusive valve-in-valve) and to allow the detection of functionally relevant PPM. In the trial it will be assessed how anatomic dimensions of patients and implanted valves relate to each other and whether they allow the prediction of hemodynamic outcome.
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| recording of hemodynamic outcome of a aortic valve in mutual dependence of anatomical facts on the basis of echocardiographic parameter | Echocardiographic evaluation of the anatomical facts e.g. Left ventricular outflow area | postprocedure before discharge (less than 30 days after implant) |
| Measure | Description | Time Frame |
|---|---|---|
| Mortality 30 days after implant | Mortality | 30 days |
| Morbidity 30 days after implant | Morbidity | 30 days |
Not provided
Inclusion Criteria:1.Patient has an indication for primary, isolated aortic valve implantation 2. Patient is above 18 Years old 3. Patient has signed patient informed consent 4. foreseen implantation of an Epic, Epic supra or Trifecta valve 5. Patient has sinus rhythm
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients with aortic valve disease selected for tissue valve implantation (routine care)
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Torsten Doenst, M.D.Ph.D. | Head of Cardiac surgery department | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Herzzentrum Dresden | Dresden | Germany | ||||
| Asklepios St. Georg |
Not provided
| ID | Term |
|---|---|
| D000082862 | Aortic Valve Disease |
| ID | Term |
|---|---|
| D006349 | Heart Valve Diseases |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| Hamburg |
| Germany |
| Department of Cardiothoracic Surgery | Jena | 07747 | Germany |
| Hospital Bogenhausen | Munich | 81925 | Germany |
| Herz- und Kreislaufzentrum Rotenburg / Fulda | Rotenburg (Wümme) | Germany |
| Krankenhaus der Barmherzigen Brüder | Trier | Germany |
| University Hospital of Ulm | Ulm | Germany |