Coronary computed tomography angiography (CCTA) is a frequently performed test for the diagnosis and/or exclusion of coronary artery disease (CAD) in appropriately selected patients. The performance of non-contrast computed tomography for the detection and quantification of coronary calcification is typically performed prior to CCTA in an effort to identify significant calcification which may influence subsequent data acquisition during the CCTA. However, performance of calcium scoring adds significant radiation and most coronary calcification is proximal in its location, potentially visualized using a focused non-contrast scan.
The purpose of this study is to prospectively compare the usefulness of a modified non-contrast CT, using a significantly shorter scan length and lower radiation parameters, as compared to standard coronary artery calcium scanning for the detection of coronary calcification that may influence subsequent CCTA performance.
Prior to undergoing CCTA, non-contrast CT scanning of the entire heart is usually performed in adults over 50-years of age in order to assess for the presence and severity of coronary artery calcium. By providing a modified CT scan with a reduced length the same data can be obtained by the imager to ensure a high quality scan while decreasing the patient's overall radiation exposure. Our objectives and specific aims to validate our hypothesis include:
Study Design Prospective, randomized single-center cohort study.
Anticipated Requirements
Facilities: Walter Reed National Military Medical Center
Duration of enrollment: 12 months
Budget: no additional budget is needed.
Subject Population
One hundred seventy-five (175) male and female adult subjects (military health beneficiaries age greater than 50 years) who are clinically referred for CCTA will be eligible for participation.
The Walter Reed National Military Medical Center Cardiology Department and Radiology Departments perform multiple clinically appropriate and indicated coronary CTA studies weekly (approximately 8-12), which will allow for ease of subject recruitment. Although there are other open studies using CCTA in our department there is not a lot of overlap in their requirements and should not prohibit enrollment in our study. This study will enroll both men and women of all ethnic origins aged ≥ 50 years. All subjects will consent for themselves. All patients' participation in this research and subsequent contribution to our medical knowledge notwithstanding, no intent to benefit patients from enrollment is implied or offered. Pregnant women will be excluded from enrollment based on:
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Modified Field of View | Active Comparator | In patients randomized to undergo the modified non-contrast CT scan to assess coronary calcification burden, this study will be performed by a radiologist and cardiologist as follows: axial acquisition obtained at 70% of the R-R interval using the following parameters: rotation time 0.35 sec; collimation of 64 x 0.625mm; detector coverage of 20.0 mm; axial thickness 2.5; tube voltage 80kV and tube current 250mA. The scan length will be from 1 cm below the carina to the level beneath the proximal coronary vessels defined as the greatest diameter of the apex of the right atrium. |
|
| Standard Field of View | Placebo Comparator | In patients randomized to standard coronary artery calcium scoring, this scan will be performed in usual axial fashion obtained at 70% of the R-R interval using the following parameters: rotation time 0.35 sec; collimation of 64 x 0.625mm; detector coverage of 20.0 mm; axial thickness 2.5; tube voltage, 120 kV and tube current 250mA. The scan length, in accordance with current protocol, will be from 1 cm below the carina through the diaphragms. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Field of View | Radiation | Non-Contrast CT Scan for coronary calcium assessment prior to CT coronary angiography |
|
| Measure | Description | Time Frame |
|---|---|---|
| Qualitative Quality Comparison | The measurement of quality in comparison of the modified versus non-modified CCTA using a qualitative (four point scale).
| Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
| Quantitative Quality Comparison | The measurement of quality in comparison of the modified versus non-modified CCTA using a quantitative score (CCTA signal, noise, signal to noise ratio): image signal and noise obtained during scan analysis by placing a circular region of interest (1 cm in diameter) within the proximal ascending aorta and there measuring Hounsfield Units (HU) which is the CCTA "signal" and standard deviation of the HU within that same region (which is the "noise"), the ratio of these signal/noise is also captured by this method. | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
| Measure | Description | Time Frame |
|---|---|---|
| Number of Patients With Coronary CT Parameter Changes (mA by 50). | Any changes in the cardiac CT after evaluation of the modified or standard calcium scoring in a change in milliamps by 50. | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Hampton A Crimm, MD | WRNMMC Cardiology Department | Principal Investigator |
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 32868247 | Derived | Crimm HA, Fergestrom NM, Dye C, Philip C, Nguyen BT, Villines TC. Focused, low tube potential, coronary calcium assessment prior to coronary CT angiography: A prospective, randomized clinical trial. J Cardiovasc Comput Tomogr. 2021 May-Jun;15(3):240-245. doi: 10.1016/j.jcct.2020.08.011. Epub 2020 Aug 22. |
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Modified Field of View | In patients randomized to undergo the modified non-contrast CT scan to assess coronary calcification burden, this study will be performed by a radiologist and cardiologist as follows: axial acquisition obtained at 70% of the R-R interval using the following parameters: rotation time 0.35 sec; collimation of 64 x 0.625mm; detector coverage of 20.0 mm; axial thickness 2.5; tube voltage 80kV and tube current 250mA. The scan length will be from 1 cm below the carina to the level beneath the proximal coronary vessels defined as the greatest diameter of the apex of the right atrium. Field of View: Non-Contrast CT Scan for coronary calcium assessment prior to CT coronary angiography |
| FG001 | Standard Field of View | In patients randomized to standard coronary artery calcium scoring, this scan will be performed in usual axial fashion obtained at 70% of the R-R interval using the following parameters: rotation time 0.35 sec; collimation of 64 x 0.625mm; detector coverage of 20.0 mm; axial thickness 2.5; tube voltage, 120 kV and tube current 250mA. The scan length, in accordance with current protocol, will be from 1 cm below the carina through the diaphragms. Field of View: Non-Contrast CT Scan for coronary calcium assessment prior to CT coronary angiography |
| Title | Milestones | Reasons Not Completed | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
82 patients were enrolled to the Modified group. As previously mentioned, one withdrew consent immediately after randomization (i.e. prior to undergoing scan). Two additional scans within the modified group were unavailable to the PI at the time of data analysis (i.e. years after the scan, due to data migration failure)
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Modified Field of View | In patients randomized to undergo the modified non-contrast CT scan to assess coronary calcification burden, this study will be performed by a radiologist and cardiologist as follows: axial acquisition obtained at 70% of the R-R interval using the following parameters: rotation time 0.35 sec; collimation of 64 x 0.625mm; detector coverage of 20.0 mm; axial thickness 2.5; tube voltage 80kV and tube current 250mA. The scan length will be from 1 cm below the carina to the level beneath the proximal coronary vessels defined as the greatest diameter of the apex of the right atrium. Field of View: Non-Contrast CT Scan for coronary calcium assessment prior to CT coronary angiography |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Qualitative Quality Comparison | The measurement of quality in comparison of the modified versus non-modified CCTA using a qualitative (four point scale).
| Within the modified group: 1 patient had previously withdrawn consent and 2 additional scans were subsequently unavailable for review at the time of measurement of the outcomes. | Posted | Mean | Inter-Quartile Range | score on a scale | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
3 years
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Modified Field of View | In patients randomized to undergo the modified non-contrast CT scan to assess coronary calcification burden, this study will be performed by a radiologist and cardiologist as follows: axial acquisition obtained at 70% of the R-R interval using the following parameters: rotation time 0.35 sec; collimation of 64 x 0.625mm; detector coverage of 20.0 mm; axial thickness 2.5; tube voltage 80kV and tube current 250mA. The scan length will be from 1 cm below the carina to the level beneath the proximal coronary vessels defined as the greatest diameter of the apex of the right atrium. Field of View: Non-Contrast CT Scan for coronary calcium assessment prior to CT coronary angiography |
Not provided
Not provided
single center design and relatively small sample size.
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Hampton Crimm | WRNMMC Cardiology | 301-295-4500 | hampton.a.crimm.mil@mail.mil |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Oct 14, 2014 | Oct 1, 2019 | Prot_SAP_000.pdf |
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Number of Patients With Coronary CT Parameter Changes (Tube Potential). | Any changes in the cardiac CT after evaluation of the modified or standard calcium scoring (i.e. increasing or decreasing the tube potential) | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
| Number of Patients With Coronary CT Using High Definition Scanning. | Any use of of the "high definition" scanning parameter after evaluation of the calcium burden by modified or standard calcium scoring. | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
| Number of Patients With Coronary CT Parameter Changes (Padding in Milliseconds). | Any changes in the cardiac CT after evaluation of the modified or standard calcium scoring in any changes in padding (milliseconds). | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
| Comparison Radiation Exposure in Non-Con CT (Dose Length Product) | The measurement of radiation exposure as DLP (measured in mSv/mGycm) in comparison of the modified versus standard calcium scoring. | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
| Comparison Radiation Exposure Contrast Coronary CT (Dose Length Product / Milli-sieverts) | The measurement of radiation exposure difference measured as DLP/milli-sieverts of the entire CCTA study on the modified versus standard calcium scoring. | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
| Number of Participants for Which There Was a Scan Termination Event | Number of patients whose coronary CTA scan was canceled by the imaging provider due to extreme levels of calcium noted during the modified or standard calcium scoring scan. | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
| BG001 | Standard Field of View | In patients randomized to standard coronary artery calcium scoring, this scan will be performed in usual axial fashion obtained at 70% of the R-R interval using the following parameters: rotation time 0.35 sec; collimation of 64 x 0.625mm; detector coverage of 20.0 mm; axial thickness 2.5; tube voltage, 120 kV and tube current 250mA. The scan length, in accordance with current protocol, will be from 1 cm below the carina through the diaphragms. Field of View: Non-Contrast CT Scan for coronary calcium assessment prior to CT coronary angiography |
| BG002 | Total | Total of all reporting groups |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Count of Participants | Participants |
|
|
|
|
| Primary | Quantitative Quality Comparison | The measurement of quality in comparison of the modified versus non-modified CCTA using a quantitative score (CCTA signal, noise, signal to noise ratio): image signal and noise obtained during scan analysis by placing a circular region of interest (1 cm in diameter) within the proximal ascending aorta and there measuring Hounsfield Units (HU) which is the CCTA "signal" and standard deviation of the HU within that same region (which is the "noise"), the ratio of these signal/noise is also captured by this method. | Posted | Mean | Standard Deviation | ratio | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
|
|
|
| Secondary | Number of Patients With Coronary CT Parameter Changes (mA by 50). | Any changes in the cardiac CT after evaluation of the modified or standard calcium scoring in a change in milliamps by 50. | Posted | Count of Participants | Participants | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
|
|
|
| Secondary | Number of Patients With Coronary CT Parameter Changes (Tube Potential). | Any changes in the cardiac CT after evaluation of the modified or standard calcium scoring (i.e. increasing or decreasing the tube potential) | Posted | Count of Participants | Participants | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
|
|
|
| Secondary | Number of Patients With Coronary CT Using High Definition Scanning. | Any use of of the "high definition" scanning parameter after evaluation of the calcium burden by modified or standard calcium scoring. | Posted | Count of Participants | Participants | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
|
|
|
| Secondary | Number of Patients With Coronary CT Parameter Changes (Padding in Milliseconds). | Any changes in the cardiac CT after evaluation of the modified or standard calcium scoring in any changes in padding (milliseconds). | Posted | Count of Participants | Participants | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
|
|
|
| Secondary | Comparison Radiation Exposure in Non-Con CT (Dose Length Product) | The measurement of radiation exposure as DLP (measured in mSv/mGycm) in comparison of the modified versus standard calcium scoring. | Posted | Mean | Standard Deviation | mSv/mGycm | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
|
|
|
| Secondary | Comparison Radiation Exposure Contrast Coronary CT (Dose Length Product / Milli-sieverts) | The measurement of radiation exposure difference measured as DLP/milli-sieverts of the entire CCTA study on the modified versus standard calcium scoring. | Posted | Mean | Standard Deviation | mSv/mGycm | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
|
|
|
| Secondary | Number of Participants for Which There Was a Scan Termination Event | Number of patients whose coronary CTA scan was canceled by the imaging provider due to extreme levels of calcium noted during the modified or standard calcium scoring scan. | Posted | Count of Participants | Participants | Following completion of data acquisition (i.e. CT scans) for all patients (last patient scan was 2/26/18), each outcome measure was then assessed (this process spanned approximately 3 months from March to June 2018). |
|
|
|
| 0 |
| 82 |
| 0 |
| 82 |
| 0 |
| 82 |
| EG001 | Standard Field of View | In patients randomized to standard coronary artery calcium scoring, this scan will be performed in usual axial fashion obtained at 70% of the R-R interval using the following parameters: rotation time 0.35 sec; collimation of 64 x 0.625mm; detector coverage of 20.0 mm; axial thickness 2.5; tube voltage, 120 kV and tube current 250mA. The scan length, in accordance with current protocol, will be from 1 cm below the carina through the diaphragms. Field of View: Non-Contrast CT Scan for coronary calcium assessment prior to CT coronary angiography | 0 | 93 | 0 | 93 | 0 | 93 |
Not provided
Not provided
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |