Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
To conduct an outpatient study testing two configurations of the bionic pancreas (bi-hormonal and insulin-only) with and without remote monitoring of hypoglycemia in 25 adult (≥ 18 years of age) subjects with type 1 diabetes in a random-order crossover study versus usual care with an insulin pump with and without remote monitoring of hypoglycemia.
The rationale for this study is to measure the safety of eliminating the glycemic monitoring that the investigators have done in all of the previous outpatient studies under both insulin only and bihormonal bionic pancreas control. The investigators are planning to transition the outpatient studies to an integrated bionic pancreas, the iLet, in the near future. The intended use of this device does not include remote monitoring, which would not be feasible on a commercial scale. Therefore, in this trial the investigators will test the effects on hypoglycemia of eliminating blood glucose related monitoring. In addition, the investigators will perform a pilot trial testing the effects of the bionic pancreas on food intake, exercise, weight and body composition. The primary purpose of this pilot is to assess the feasibility of performing these measurements in the context of a larger trial and to collect data that can be used to power sub-studies of pivotal trials looking at these outcomes. Finally, the investigators will test the accuracy of two new CGM devices to see if they have sufficient accuracy to provide glucose data to the bionic pancreas. If so, this would provide new options for users who may have difficulties with the only currently validated CGM for this purpose, the Dexcom G4 AP / G5 platform.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Usual Care Arm - Monitored | Active Comparator | Subjects will manage their own diabetes and will wear a blinded Dexcom G4 CGM to record their glucose data during the week. They will be monitored for CGM connectivity and hypoglycemia. Monitored for hypoglycemia |
|
| Usual Care Arm - Unmonitored | Active Comparator | Subjects will manage their own diabetes and will wear a blinded Dexcom G4 CGM to record their glucose data during the week. They will be monitored only for CGM connectivity, not hypoglycemia. Not monitored for hypoglycemia |
|
| Bihormonal Bionic Pancreas - Monitored | Experimental | Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G4 CGM, an insulin and glucagon pump and an iPhone running the study algorithm. They will be monitored for CGM connectivity and hypoglycemia. Monitored for hypoglycemia |
|
| Bihormonal Bionic Pancreas - Unmonitored | Experimental | Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G4 CGM, an insulin and glucagon pump and an iPhone running the study algorithm. They will be monitored only for CGM connectivity, not hypoglycemia. Not monitored for hypoglycemia |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Bihormonal Bionic Pancreas | Device | Participants will wear a Bionic Pancreas that uses glucagon and insulin (bihormonal) to automate their glucose control based on continuous glucose monitor readings. |
| Measure | Description | Time Frame |
|---|---|---|
| Percentage of Time Spent With Dexcom CGMG < 60 mg/dl | A measure of hypoglycemia capturing amount of time the continuous glucose monitor is reading less than 60 mg/dl | days 2-7 |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Acceptable contraception methods include: Oral contraceptive pill (OCP), Intrauterine Device (IUD, hormonal or copper), Male condoms, Female condoms, Diaphragm or cervical cap with spermicide, Contraceptive patch (such as OrthoEvra), Contraceptive implant (such as Implanon, Nexplanon), Vaginal ring (such as NuvaRing), Progestin shot (such as Depo-Provera), Male partner with a vasectomy proven to be effective by semen analysis
Need to go outside of the designated geographic boundaries during the study
Current alcohol abuse (intake averaging > 3 drinks daily in last 30 days), use of marijuana within 1 month of enrollment, or other substance abuse (use within the last 6 months of controlled substances other than marijuana without a prescription)
Unwilling or unable to refrain from drinking more than 2 drinks in an hour or more than 4 drinks in a day or use of marijuana during the trial
Unwilling or unable or to avoid use of drugs that may dull the sensorium, reduce sensitivity to symptoms of hypoglycemia, or hinder decision making during the period of participation in the study (use of beta blockers will be allowed as long as the dose is stable and the subject does not meet the criteria for hypoglycemia unawareness while taking that stable dose, but use of benzodiazepines or narcotics, even if by prescription, may be excluded according to the judgment of the principal investigator)
History of liver disease that is expected to interfere with the anti-hypoglycemia action of glucagon (e.g. liver failure or cirrhosis). Other liver disease (i.e. active hepatitis, steatosis, active biliary disease, any tumor of the liver, hemochromatosis, glycogen storage disease) may exclude the subject if it causes significant compromise to liver function or may do so in an unpredictable fashion.
Renal failure on dialysis
Personal history of cystic fibrosis, pancreatitis, pancreatic tumor, or any other pancreatic disease
Any known history of coronary artery disease including, but not limited to, history of myocardial infarction, stress test showing ischemia, history of angina, or history of intervention such as coronary artery bypass grafting, percutaneous coronary intervention, or enzymatic lysis of a presumed coronary occlusion)
Abnormal EKG consistent with coronary artery disease or increased risk of malignant arrhythmia including, but not limited to, evidence of active ischemia, prior myocardial infarction, proximal LAD critical stenosis (Wellen's sign), prolonged QT interval (> 440 ms). Non-specific ST segment and T wave changes are not grounds for exclusion in the absence of symptoms or history of heart disease. A reassuring evaluation by a cardiologist after an abnormal EKG finding may allow participation.
Congestive heart failure (established history of CHF, lower extremity edema, paroxysmal nocturnal dyspnea, or orthopnea)
History of TIA or stroke
Seizure disorder, history of any non-hypoglycemic seizure within the last two years, or ongoing treatment with anticonvulsants
History of hypoglycemic seizures (grand-mal) or coma in the last year
History of pheochromocytoma: fractionated metanephrines will be tested in patients with history increasing the risk for a catecholamine secreting tumor:
History of adrenal disease or tumor
Hypertension with systolic BP ≥160 mm Hg or diastolic BP ≥100 despite treatment
Untreated or inadequately treated mental illness (indicators would include symptoms such as psychosis, hallucinations, mania, and any psychiatric hospitalization in the last year), or treatment with anti-psychotic medications that are known to affect glucose regulation.
Electrically powered implants (e.g. cochlear implants, neurostimulators) that might be susceptible to RF interference
The presence of any other active implanted device
Unable to completely avoid acetaminophen for duration of study
Unable to completely avoid ascorbic acid (Vitamin C) for duration of study
Unable to completely avoid salicylic acid (used in some pain relievers such as Aspirin and some skin care products)
History of adverse reaction to glucagon (including allergy) besides nausea and vomiting
Established history of allergy or severe reaction to adhesive or tape that must be used in the study
History of eating disorder within the last 2 years, such as anorexia, bulimia, or diabulemia or omission of insulin to manipulate weight
History of intentional, inappropriate administration of insulin leading to severe hypoglycemia requiring treatment
Use of oral (e.g. thiazolidinediones, biguanides, sulfonylureas, glitinides, DPP-4 inhibitors, SGLT-2 inhibitors) anti-diabetic medications
Lives in or frequents areas with poor Verizon wireless network coverage (which would prevent remote monitoring)
Any factors that, in the opinion of the principal investigator would interfere with the safe completion of the study
A condition preventing or complicating the placement, operation or removal of the Senseonics sensor or wearing of transmitter, including upper extremity deformities or skin condition
Currently receiving (or likely to need during the study period): immunosuppressant therapy, chemotherapy, anticoagulant/antithrombotic therapy (excluding aspirin), glucocorticoids (excluding ophthalmic or nasal). This does include the use of inhaled and topical glucocorticoids and antibiotics for chronic infection
A condition requiring or likely requiring magnetic resonance imaging (MRI), Computed Tomography (CT) scan, or high-frequency electrical heat (diathermy)
A known topical or local anesthetic allergy
A known glucocorticoids allergy
The presence of any other CGM sensor or transmitter located in the upper arm (other location is acceptable)
Hemoglobin < 12 g/dl
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Steven J Russell, MD, PhD | Massachusetts General Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| MGH Diabetes Research Center | Boston | Massachusetts | 02114 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
27 subjects were enrolled, but only 24 participated in the study. 2 subjects were ineligible, and 1 could not participate for scheduling reasons. 1 of the 24 was terminated by the investigator during the first arm of the study, so that 1 subject only started 1 arm. 23 subjects finished that arm, and 23 subjects started and finished the other arms
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | BBPM First, Then BBP, Then UCM, Then UC, Then IOBPM, Then IOBP | UC=usual care-Subjects will manage their own diabetes and wear a Dexcom CGM G5 to record their glucose data during the week IOBP-insulin only bionic pancreas. Subjects will wear the insulin only bionic pancreas consisting of a Dexcom G5 CGM, an insulin pump, and an iPhone running the study algorithm. BBP- bihormonal bionic pancreas- Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G5 CGM, and insulin and glucagon pump and an iPhone running the study algorithm M-arm includes real-time remote monitoring for hypoglycemia |
| FG001 | UCM First, Then UC, Then IOBPM, Then IOBP, Then BBPM, Then BBP | UC=usual care-Subjects will manage their own diabetes and wear a Dexcom CGM G5 to record their glucose data during the week IOBP-insulin only bionic pancreas. Subjects will wear the insulin only bionic pancreas consisting of a Dexcom G5 CGM, an insulin pump, and an iPhone running the study algorithm. BBP- bihormonal bionic pancreas- Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G5 CGM, and insulin and glucagon pump and an iPhone running the study algorithm M-arm includes real-time remote monitoring for hypoglycemia |
| FG002 | IOBPM First, Then IOBP, Then BBPM, Then BBP, Then UCM, Then UC | UC=usual care-Subjects will manage their own diabetes and wear a Dexcom CGM G5 to record their glucose data during the week IOBP-insulin only bionic pancreas. Subjects will wear the insulin only bionic pancreas consisting of a Dexcom G5 CGM, an insulin pump, and an iPhone running the study algorithm. BBP- bihormonal bionic pancreas- Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G5 CGM, and insulin and glucagon pump and an iPhone running the study algorithm M-arm includes real-time remote monitoring for hypoglycemia |
| FG003 | UC First, Then UCM, Then BBP, Then BBPM, Then IOBP, Then IOBPM | UC=usual care-Subjects will manage their own diabetes and wear a Dexcom CGM G5 to record their glucose data during the week IOBP-insulin only bionic pancreas. Subjects will wear the insulin only bionic pancreas consisting of a Dexcom G5 CGM, an insulin pump, and an iPhone running the study algorithm. BBP- bihormonal bionic pancreas- Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G5 CGM, and insulin and glucagon pump and an iPhone running the study algorithm M-arm includes real-time remote monitoring for hypoglycemia |
| FG004 | IOBP First, Then IOBPM, Then UC, Then UCM, Then BBP, Then BBPM | UC=usual care-Subjects will manage their own diabetes and wear a Dexcom CGM G5 to record their glucose data during the week IOBP-insulin only bionic pancreas. Subjects will wear the insulin only bionic pancreas consisting of a Dexcom G5 CGM, an insulin pump, and an iPhone running the study algorithm. BBP- bihormonal bionic pancreas- Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G5 CGM, and insulin and glucagon pump and an iPhone running the study algorithm M-arm includes real-time remote monitoring for hypoglycemia |
| FG005 | BBP First, Then BBPM, Then IOBP, Then IOBPM, Then UC, Then UCM | UC=usual care-Subjects will manage their own diabetes and wear a Dexcom CGM G5 to record their glucose data during the week IOBP-insulin only bionic pancreas. Subjects will wear the insulin only bionic pancreas consisting of a Dexcom G5 CGM, an insulin pump, and an iPhone running the study algorithm. BBP- bihormonal bionic pancreas- Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G5 CGM, and insulin and glucagon pump and an iPhone running the study algorithm M-arm includes real-time remote monitoring for hypoglycemia |
| Title | Milestones | Reasons Not Completed | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | All Participants | All participants who began participating in the study |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Percentage of Time Spent With Dexcom CGMG < 60 mg/dl | A measure of hypoglycemia capturing amount of time the continuous glucose monitor is reading less than 60 mg/dl | Posted | Mean | Standard Deviation | percentage of time | days 2-7 |
|
6 weeks
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Usual Care Arm - Monitored | Subjects will manage their own diabetes and will wear a blinded Dexcom G4 CGM to record their glucose data during the week. They will be monitored for CGM connectivity and hypoglycemia. Monitored for hypoglycemia Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity and hypoglycemia, and will be notified by study staff any time their continuous glucose monitor reads less than 50 mg/dl for 15 mintues. |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Hypoglycemia | Endocrine disorders | Non-systematic Assessment | The subject reported a hypoglycemic event that he was not called for. Remote monitoring did not see this or notify study staff. The subject reported that he treated using oral carbohydrates, and it resolved without incident. |
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Courtney Balliro, BS RN CDE | MGH | 617-726-1242 | cballiro@partners.org |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Apr 10, 2017 | Feb 7, 2018 | Prot_SAP_000.pdf |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Insulin Only Bionic Pancreas - Monitored | Experimental | Subjects will wear the insulin only bionic pancreas, consisting of a Dexcom G4 CGM, an insulin pump, and an iPhone running the study algorithm. They will be monitored for CGM connectivity and hypoglycemia. Monitored for hypoglycemia |
|
| Insulin Only Bionic Pancreas - Unmonitored | Experimental | Subjects will wear the insulin only bionic pancreas, consisting of a Dexcom G4 CGM, an insulin pump, and an iPhone running the study algorithm. They will be monitored only for CGM connectivity, not hypoglycemia. Not monitored for hypoglycemia |
|
| Insulin Only Bionic Pancreas | Device | Participants will wear a Bionic Pancreas that uses just insulin (insulin-only) to automate their glucose control based on continuous glucose monitor readings. |
|
| Monitored for Hypoglycemia | Other | During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity and hypoglycemia, and will be notified by study staff any time their continuous glucose monitor reads less than 50 mg/dl for 15 mintues. |
|
| Not Monitored for Hypoglycemia | Other | During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity only, not hypoglycemia. |
|
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Hemoglobin A1c | Mean | Standard Deviation | percent |
|
| Usual Care Arm - Unmonitored |
Subjects will manage their own diabetes and will wear a blinded Dexcom G4 CGM to record their glucose data during the week. They will be monitored only for CGM connectivity, not hypoglycemia. Not monitored for hypoglycemia Not Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity only, not hypoglycemia. |
| OG002 | Bihormonal Bionic Pancreas - Monitored | Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G4 CGM, an insulin and glucagon pump and an iPhone running the study algorithm. They will be monitored for CGM connectivity and hypoglycemia. Monitored for hypoglycemia Bihormonal Bionic Pancreas: Participants will wear a Bionic Pancreas that uses glucagon and insulin (bihormonal) to automate their glucose control based on continuous glucose monitor readings. Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity and hypoglycemia, and will be notified by study staff any time their continuous glucose monitor reads less than 50 mg/dl for 15 mintues. |
| OG003 | Bihormonal Bionic Pancreas - Unmonitored | Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G4 CGM, an insulin and glucagon pump and an iPhone running the study algorithm. They will be monitored only for CGM connectivity, not hypoglycemia. Not monitored for hypoglycemia Bihormonal Bionic Pancreas: Participants will wear a Bionic Pancreas that uses glucagon and insulin (bihormonal) to automate their glucose control based on continuous glucose monitor readings. Not Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity only, not hypoglycemia. |
| OG004 | Insulin Only Bionic Pancreas - Monitored | Subjects will wear the insulin only bionic pancreas, consisting of a Dexcom G4 CGM, an insulin pump, and an iPhone running the study algorithm. They will be monitored for CGM connectivity and hypoglycemia. Monitored for hypoglycemia Insulin Only Bionic Pancreas: Participants will wear a Bionic Pancreas that uses just insulin (insulin-only) to automate their glucose control based on continuous glucose monitor readings. Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity and hypoglycemia, and will be notified by study staff any time their continuous glucose monitor reads less than 50 mg/dl for 15 mintues. |
| OG005 | Insulin Only Bionic Pancreas - Unmonitored | Subjects will wear the insulin only bionic pancreas, consisting of a Dexcom G4 CGM, an insulin pump, and an iPhone running the study algorithm. They will be monitored only for CGM connectivity, not hypoglycemia. Not monitored for hypoglycemia Insulin Only Bionic Pancreas: Participants will wear a Bionic Pancreas that uses just insulin (insulin-only) to automate their glucose control based on continuous glucose monitor readings. Not Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity only, not hypoglycemia. |
|
|
| 0 |
| 24 |
| 1 |
| 24 |
| 0 |
| 24 |
| EG001 | Usual Care Arm - Unmonitored | Subjects will manage their own diabetes and will wear a blinded Dexcom G4 CGM to record their glucose data during the week. They will be monitored only for CGM connectivity, not hypoglycemia. Not monitored for hypoglycemia Not Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity only, not hypoglycemia. | 0 | 24 | 0 | 24 | 0 | 24 |
| EG002 | Bihormonal Bionic Pancreas - Monitored | Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G4 CGM, an insulin and glucagon pump and an iPhone running the study algorithm. They will be monitored for CGM connectivity and hypoglycemia. Monitored for hypoglycemia Bihormonal Bionic Pancreas: Participants will wear a Bionic Pancreas that uses glucagon and insulin (bihormonal) to automate their glucose control based on continuous glucose monitor readings. Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity and hypoglycemia, and will be notified by study staff any time their continuous glucose monitor reads less than 50 mg/dl for 15 mintues. | 0 | 24 | 0 | 24 | 0 | 24 |
| EG003 | Bihormonal Bionic Pancreas - Unmonitored | Subjects will wear the bihormonal bionic pancreas, consisting of a Dexcom G4 CGM, an insulin and glucagon pump and an iPhone running the study algorithm. They will be monitored only for CGM connectivity, not hypoglycemia. Not monitored for hypoglycemia Bihormonal Bionic Pancreas: Participants will wear a Bionic Pancreas that uses glucagon and insulin (bihormonal) to automate their glucose control based on continuous glucose monitor readings. Not Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity only, not hypoglycemia. | 0 | 24 | 0 | 24 | 0 | 24 |
| EG004 | Insulin Only Bionic Pancreas - Monitored | Subjects will wear the insulin only bionic pancreas, consisting of a Dexcom G4 CGM, an insulin pump, and an iPhone running the study algorithm. They will be monitored for CGM connectivity and hypoglycemia. Monitored for hypoglycemia Insulin Only Bionic Pancreas: Participants will wear a Bionic Pancreas that uses just insulin (insulin-only) to automate their glucose control based on continuous glucose monitor readings. Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity and hypoglycemia, and will be notified by study staff any time their continuous glucose monitor reads less than 50 mg/dl for 15 mintues. | 0 | 24 | 0 | 24 | 0 | 24 |
| EG005 | Insulin Only Bionic Pancreas - Unmonitored | Subjects will wear the insulin only bionic pancreas, consisting of a Dexcom G4 CGM, an insulin pump, and an iPhone running the study algorithm. They will be monitored only for CGM connectivity, not hypoglycemia. Not monitored for hypoglycemia Insulin Only Bionic Pancreas: Participants will wear a Bionic Pancreas that uses just insulin (insulin-only) to automate their glucose control based on continuous glucose monitor readings. Not Monitored for Hypoglycemia: During half of the study arms (one each bihormonal bionic pancreas, insulin-only bionic pancreas and usual care) the subjects will be remotely monitored for device connectivity only, not hypoglycemia. | 0 | 24 | 0 | 24 | 0 | 24 |
|
Not provided
Not provided
Not provided