The study will evaluate the accuracy of BP measurements by a new algorithm to be embedded to the existing CE-marked WinPack device, compared to two reference devices (one oscillometric and one volume-clamp device), in healthy subjects and patients undergoing a standardized physical-activity hypertensive protocol.
Current standard for patient monitoring in acute care such as intensive care units (ICU), operating rooms (OR) or emergency rooms (ER) is the use of expensive, bulky and uncomfortable monitors.
Unfortunately, once discharged from the acute care setting and transferred to a general division for example (low acuity), patients are left with manual measurements of vital signs every 4 to 6 hours, depending on the available resources in nursing. Furthermore, these measurements reflect only the results of the time the measurement is taken (spot check). The combination of manual spot checks and lack of innovative medical technology in 60% of hospital care settings (all non-ICUs and non-OR) represents an important limitation to patient follow-up, with its associated risks and costs.
In particular, when referring to the monitoring of blood pressure (BP), current monitoring practice relies on the use of occlusive pneumatic cuffs inflated around the arm. Based on oscillometric technique, occlusive cuffs not only are uncomfortable, but they provide only intermittent measurements, with the inability to provide a full view of the BP regulation landscape. Therefore, un-detected hypertensive events can be omitted, putting the patient at risk.
The continuous, comfortable and portable measurement of BP in low acuity hospital departments is a major unsolved problem of modern healthcare systems with regards to patient monitoring and safety.
Winmedical (device manufacturer) commercializes a wearable multi-parametric modular medical system, WinPack, to deliver continuous real-time monitoring and recording of vital signs, such as electrocardiography (ECG), respiration rate, BP, blood oxygen saturation, body temperature, and posture, in low-acuity departments to increase the overall clinical performance. A new algorithm to process the raw physiological signals acquired by the WinPack to provide more accurate and more continuous BP measurement is now to be tested.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| WinMedical WinPack device | Experimental | 50 volunteers undergoing experimental protocol according to IEEE 1708:2014 standard |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| WinMedical WinPack device | Device |
|
| Measure | Description | Time Frame |
|---|---|---|
| Assessment of the accuracy of a novel algorithm to extract BP estimates from data acquired by the WinPack system, when compared to gold-standard BP devices, with respect to limits of agreement as stated by the IEEE 1708:2014 standard | 3 Months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Cyril Pellaton, Dr | HNE - Hôpital Neuchâtelois, Site de Pourtalès | Principal Investigator |