The purpose of this trial is to determine the effectiveness, safety and tolerability of robot-assisted rehabilitation using ARBOT in patients with ankle dysfunction resulting from work related ankle fractures, compared with conventional rehabilitation programs.
INTRODUCTION:
Robotic devices for lower-limb rehabilitation have been mainly tested in neurologically injured patients. Up to now, clinical studies using robotic training in orthopedic conditions are few. A pilot study was carried out at INAIL Physical Rehabilitation Center of Volterra using ARBOT, a prototypal robotic system for ankle rehabilitation. This device has been developed by IIT - Italian Institute of Technology and it consists of a two-degree-of-freedom electromechanical platform which is able to perform most of the exercises foreseen by the standard rehabilitation programs. By virtue of its innovative motion system and control architecture, ARBOT integrates multiple rehabilitation equipment functions, performing also special exercise programs such as elastic and fluid-dynamic resistance.
ARBOT allows training according to programmed sequences, in order to promote range of movement, muscular function and proprioceptive recovery. Exercises can be performed with or without bearing weight. Moreover, ARBOT is a powerful evaluation instrument for physiotherapists in order to verify and record the results of rehabilitative intervention.
The primary aim of this trial was to determine the effectiveness, safety and tolerability of robot-assisted rehabilitation using ARBOT in patients with ankle dysfunction resulting from work related ankle fractures, compared with conventional rehabilitation programs. Secondary objectives was to investigate correlations among physical and disability parameters, to collect data in order to define further study protocols and improve ARBOT's performance and ergonomics, and ultimately to evaluate patient satisfaction with respect to robot assisted rehabilitation programs.
METHODS:
Thirty-two patients with work related injuries resulting in ankle and/or hindfoot fractures and subsequent to the immobilization phase was enrolled in an open randomized controlled trial over a 30 month period. Each participant was randomly allocated to experimental or control group and received a 4-week rehabilitation program (20 sessions, for 5 days/week from admission to discharge in the Rehabilitation Centre) and weekly robotic and clinical assessments.
Subjects in the experimental group were treated using ARBOT with passive, active and active assisted range-of-motion exercises, resistive exercises in isometric, isotonic, isokinetic, elastic and fluid-dynamic conditions, and proprioceptive training. Control subjects were assisted by a physiotherapist during range of motion recovery exercises and performed resistive and proprioceptive training using Biodex System 3 dynamometer and ProKin PK254 mobile electronic platform.
The assessment sessions included measurements of dorsiflexion ROM, isometric and isokinetic plantar-flexion torque and proprioceptive performance with ARBOT and 2 minutes walking and timed stair climbing test, LEFS-Lower Extremity Functional Scale and AOFAS-Ankle-Hindfoot Scale.
Site monitoring of the study has been conducted according to the standard ISO 14155.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Experimental: ARBOT Group | Experimental | The patients in the "ARBOT Group" underwent to following interventions:
|
|
| Control Group | Other | The patients in the Control Group underwent to following interventions:
|
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Specific ankle rehabilitation by ARBOT device | Device | ARBOT is a programmable robotic device consisting in a two-degree-of-freedom electromechanical platform developed by Italian Institute of Technology - Advanced Robotics and Rehab Technologies. It is composed of a fixed base, a central strut, a moving platform supporting patient's foot and three actuated limbs with a universal-prismatic-spherical kinematic chain. A six-axis force/torque sensor mounted between the moving platform and the footplate senses the human-robot interaction force and torque. The device is interfaced to a standard all-in-one touch screen Personal Computer with graphic applications to give patients visual feedback in real time. |
| Measure | Description | Time Frame |
|---|---|---|
| Change of Dorsiflexion Range of Motion | At baseline and after 1, 2, 3 and 4 weeks intervention | |
| Change of Isometric peak torque at 0° and 10° of plantar flexion | At baseline and after 2 and 4 weeks intervention | |
| Change of Isokinetic plantar-flexion torque at speed of 30°, 60°, 120°/sec | At baseline and after 2 and 4 weeks intervention | |
| Change of 2 Minute Walk Test (2MWT) | At baseline and after 2 and 4 weeks intervention | |
| Side Effects using ARBOT | Through study completion, up to 4 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Timed Stair Climbing Test (10 steps) | At baseline and after 2 and 4 weeks intervention | |
| Proprioceptive tests (time taking and accuracy) | At baseline and after after 2 and 4 weeks intervention | |
Not provided
Inclusion Criteria:
Functional limitation following work-related ankle injuries, including:
Post-immobilization phase;
Time interval since fracture event of less than 12 months;
Signed informed consent acquisition.
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Paolo Catitti, MD | INAIL - Centro di Riabilitazione Motoria di Volterra | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| INAIL - Centro di Riabilitazione Motoria di Volterra | Volterra | Pisa | 56048 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| Background | Saglia JA, Tsagarakis NG, Dai JS, Caldwell DG. Control Strategies for Patient-Assisted Training Using the Ankle Rehabilitation Robot (ARBOT). IEEE ASME TRANSACTIONS ON MECHATRONICS 2013; PP (99): 1-10. | ||
| Background | Saglia JA, Tsagarakis NG, Dai JS, Caldwell DG. A high-performance redundantly actuated parallel mechanism for ankle rehabilitation. International Journal of Robotics Research 2009; 28 (9): 1216-1227. | ||
| Background | Saglia JA, Tsagarakis NG, Dai JS, Caldwell DG. Inverse-Kinematics-Based Control of a Redundantly Actuated Platform for Rehabilitation. Journal of Systems and Control Engineering, IMechE Proceedings 2009; 223 (1): 53-70. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| General Rehabilitation | Other | All patients underwent general rehabilitation (gait training, aerobic conditioning), including - if necessary - an initial weight training phase before the functional full weight-bearing program. |
|
| Specific ankle rehabilitation performed by physiotherapist | Other | Subjects in the control group underwent manually assisted range of motion exercises. |
|
| Specific ankle rehabilitation by Biodex System 3 dynamometer | Device | Subjects in the control group performed non-robotic resistive training using a Biodex System 3 dynamometer |
|
| Specific ankle rehabilitation by ProKin PK254 platform | Device | Subjects in the control group performed non-robotic proprioceptive training using a ProKin PK254 mobile electronic platform. |
|
| Pain (VAS 0-10) |
| At baseline and after 1, 2, 3 and 4 weeks intervention |
| LEFS - The Lower Extremity Functional Scale | At baseline and after after 4 weeks intervention |
| AOFAS - Ankle-Hindfoot Scale | At baseline and after 4 weeks intervention |
| Patient Satisfaction (VAS 0-10) | After 4 weeks intervention |
| ID | Term |
|---|---|
| D064386 | Ankle Fractures |
| ID | Term |
|---|---|
| D050723 | Fractures, Bone |
| D014947 | Wounds and Injuries |
| D016512 | Ankle Injuries |
| D007869 | Leg Injuries |
Not provided