Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The investigator's workplace and department were changed so that the study could no longer be carried out.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Hypotension often happens immediately after anesthetic induction. Particularly in 5-10 minutes after anesthetic induction it is reported to happen more frequently. Patients may have preexisting hypovolemia resulting from dehydration and impaired compensatory responses, which increase the risk. However, it is still challenging to assess intravascular volume status in spontaneously breathing patients before anesthetic induction. Recently, the measurement of corrected flow time in carotid artery was introduced as quite useful, simple and noninvasive for the evaluation of circulating blood volume. The aim of this study is to evaluate whether corrected carotid artery flow time as determined by ultrasonography in spontaneously breathing patients before general anesthesia can predict hypotension after induction.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Hypotension after anesthetic induction group | Patients with hypotension after anesthetic induction |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| ultrasonographic measurement of corrected flow time(FTc) in carotid artery | Procedure | Corrected carotid artery flow time is measured using 10-5 MHz linear probe on a portable ultrasound machine. On the two-dimensional image, the optimal image of the long-axis view is obtained at the left common carotid artery. The sample volume is placed on the center of the lumen, 2 cm proximal to the bulb, and a pulsed wave Doppler examination was performed. Then, cardiac cycle time and carotid flow time is measured. Carotid flow time is measured between the upstroke of the flow tracing and the dicrotic notch, and it is corrected for pulse rate by dividing flow time by the square root of the cardiac cycle time to calculate corrected carotid artery flow time (flow time/√cycle time). The blood pressure was taken before anesthetic induction and every two minutes after anesthetic induction till ten minutes after endotracheal intubation. |
| Measure | Description | Time Frame |
|---|---|---|
| corrected flow time (FTc) in carotid artery | the area under the receiver operating characteristics curve of corrected flow time in carotid artery measured by ultrasonography to predict hypotension after anesthetic induction | 10 minutes before induction of general anesthesia. |
Not provided
Not provided
Inclusion Criteria:
• adult patients (19-80 years of age) who were scheduled to undergo elective surgery under general anesthesia
Exclusion Criteria:
Not provided
Not provided
Patients who were scheduled to undergo elective surgery under general anesthesia
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institue, Yonsei Universiy College of Medicine | Seoul | 03722 | South Korea |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|