Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Patients with colorectal adenomas are suggested to receive polypectomy. A substantial number of adenomas may be missed in patients with polyps found by previous colonoscopy. And water exchange (WE) method may increase the detection of missed adenoma compared with traditional air insufflation (AI) colonoscopy. The investigators aim to investigate whether water exchange colonoscopy method, compared with air insufflation method, can improve the detection of missed adenomas in patients undergoing selective polypectomy.
For WE method, the air pump was turned off for the full duration of insertion to avoid inadvertent air insufflations and colon elongation. Residual air in the lumen was suctioned to minimize angulations at flexures. Water at 37°C was infused with a pump (Olympus) through the biopsy channel to confirm correct tip orientation for scope advancement. The infused water was removed predominantly by suction when the colonoscope was smoothly advanced during the insertion phase, and turbid luminal water due to residual feces was exchanged by clean water until the lumen was clearly visualized. Occasionally, if it was difficult to determine whether the colonoscope tip was in the cecum, air was allowed to be insufflated for observation. If the position of the scope tip was confirmed to be not in the cecum, insufflated air would be removed by suction and the WE method would be continuously used until successful intubation.
For the AI method, water was not used, and air was insufflated during insertion.
Air was insufflated to distend the lumen for inspection and biopsy or polypectomy during withdrawal for both methods. Polyps will be removed by forceps biopsy (polyps size <3mm), cold snare technique (3-6mm) or endoscopic mucosal resection (size≥6mm).
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Water exchange (WE) method | Experimental | Water exchange (WE) method was used for insertion to the cecum. |
|
| Air insufflation (AI) method | Active Comparator | Air insufflation (AI) method was used for insertion to the cecum. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Water exchange (WE) method | Other | Water exchange (WE) method was used for insertion to the cecum. And air was insufflated to distend the lumen for inspection and biopsy or polypectomy during withdrawal procedure. |
| Measure | Description | Time Frame |
|---|---|---|
| Adenoma miss rate | Adenoma miss rate was calculated as the number of patients with one and more additional adenomas during polypectomy procedure divided by the total number of patients in each group. | 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| adenoma-level miss rate | Adenoma-level miss rate was calculated as the number of additional adenomas detected in polypectomy procedure divided by the total number of adenomas in each group. | 12 months |
| Advanced adenoma miss rate/Miss advanced adenoma per colonoscopy |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Gui Ren, MD | Contact | +86298477136 | renguigz@hotmail.com |
| Name | Affiliation | Role |
|---|---|---|
| Yanglin Pan, MD | Xijing Hospital of Digestive Diseases | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Endoscopic center, Xijing Hospital of Digestive Diseases | Recruiting | Xi'an | Shaanxi | 710032 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 26873868 | Background | Veitch AM, Vanbiervliet G, Gershlick AH, Boustiere C, Baglin TP, Smith LA, Radaelli F, Knight E, Gralnek IM, Hassan C, Dumonceau JM. Endoscopy in patients on antiplatelet or anticoagulant therapy, including direct oral anticoagulants: British Society of Gastroenterology (BSG) and European Society of Gastrointestinal Endoscopy (ESGE) guidelines. Gut. 2016 Mar;65(3):374-89. doi: 10.1136/gutjnl-2015-311110. | |
| 20579648 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000236 | Adenoma |
| D011127 | Polyps |
| ID | Term |
|---|---|
| D009375 | Neoplasms, Glandular and Epithelial |
| D009370 | Neoplasms by Histologic Type |
| D009369 | Neoplasms |
| D020763 | Pathological Conditions, Anatomical |
Not provided
Not provided
| ID | Term |
|---|---|
| D008722 | Methods |
| ID | Term |
|---|---|
| D008919 | Investigative Techniques |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Air insufflation (AI) method. | Other | Air insufflation (AI) method was used for insertion to the cecum. And air was insufflated to distend the lumen for inspection and biopsy or polypectomy during withdrawal procedure. |
|
Advanced adenoma: any with 3 or more adenomas of any size, 1 or more large adenomas 1 cm, or 1 or more adenomas with villous architecture or highgrade dysplasia. |
| 12 months |
| Adenoma per positive patient (APP) | The mean number of adenoma per positive patient | 12 months |
| Quality of Bowel Preparation | The Boston Bowel Preparation Scale (BBPS): cleanliness of each part of the colon: 0=unprepared colon segment with mucosa not seen because of solid stool that cannot be cleared; 1=portion of mucosa of the colon segment seen, but other areas of the colon segment not well seen because of staining, residual stool, and/or opaque liquid; 2=minor amount of residual staining, small fragments of stool and/or opaque liquid, but mucosa of colon segment seen well; 3=entire mucosa of colon segment seen well with no residual staining, small fragments of stool, or opaque liquid. | 12 months |
| Complication rate | Bleeding, perforation and others | 12 months |
| Pain Scores on the Visual Analog Scale compared with previous colonoscopy | 0 = no pain, to 10 = most severe pain | 12 months |
| Background |
| Hewett DG, Rex DK. Cap-fitted colonoscopy: a randomized, tandem colonoscopy study of adenoma miss rates. Gastrointest Endosc. 2010 Oct;72(4):775-81. doi: 10.1016/j.gie.2010.04.030. Epub 2010 Jun 25. |
| 33390353 | Derived | Ren G, Wang X, Luo H, Yao S, Liang S, Zhang L, Dong T, Chen L, Tao Q, Guo X, Han Y, Pan Y. Effect of water exchange method on adenoma miss rate of patients undergoing selective polypectomy: A randomized controlled trial. Dig Liver Dis. 2021 May;53(5):625-630. doi: 10.1016/j.dld.2020.11.012. Epub 2020 Dec 31. |
| D013568 | Pathological Conditions, Signs and Symptoms |