This is a single center, prospective study to evaluate the efficacy and reproducibility of frequency doubling technology (FDT)-based visual field devices compared to conventional Humphrey Visual Field (HVF) perimetry. The investigators plan to enroll 500 patients in this study.
Glaucoma is a leading cause of irreversible and preventable blindness world-wide. Insufficient evidence exists to support routine screening for glaucoma in a primary care setting due to the relatively low prevalence of the disease (Guirguis-Blake, 2005 and Moyer, 2013). Frequency doubling technology (FDT)-based perimetry is a relatively inexpensive and portable visual field testing device with a short testing time that has shown reasonable efficacy, sensitivity and specificity in screening for glaucoma in clinic- and community-based settings (Mansberger, 2005 and Nomoto 2009).
The aim of our study is to compare the efficacy and reproducibility of FDT perimetry platforms compared with Humphrey Visual Field (HVF) perimetry (which is the gold clinical standard in clinics and hospitals) in detecting glaucomatous visual field defects.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Experimental | Experimental | FDT visual field will be compared to standard HVF in detecting glaucomatous visual field loss |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| FDT visual field | Device |
| ||
| Standard HVF |
| Measure | Description | Time Frame |
|---|---|---|
| Pattern of visual field loss in FDT visual fields as compared with standard HVF | Visual Field | The investigators anticipate to enroll the subjects over a period of 12 months. The estimated time required for data analysis is 6 months following enrollment of all subjects. |
| Measure | Description | Time Frame |
|---|---|---|
| Mean deviation (MD) in FDT visual fields as compared with standard HVF | Visual Field | The investigators anticipate to enroll the subjects over a period of 12 months. The estimated time required for data analysis is 6 months following enrollment of all subjects. |
| Pattern standard deviation (PSD) in FDT visual fields as compared with standard HVF |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Richard K Lee, MD, PhD | Contact | 305-326-6000 | rlee@med.miami.edu |
| Name | Affiliation | Role |
|---|---|---|
| Richard Lee, MD, PhD | University of Miami / Bascom Palmer Eye Institute | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Bascom Palmer Eye Institute, University of Miami Miller School of Medicine | Recruiting | Miami | Florida | 33136 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 16225022 | Background | Guirguis-Blake J. Rationale for the USPSTF recommendation on screening for glaucoma. Am Fam Physician. 2005 Oct 1;72(7):1184, 1187. No abstract available. | |
| 24325017 | Background | Moyer VA; U.S. Preventive Services Task Force. Screening for glaucoma: U.S. Preventive Services Task Force Recommendation Statement. Ann Intern Med. 2013 Oct 1;159(7):484-9. doi: 10.7326/0003-4819-159-6-201309170-00686. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D005901 | Glaucoma |
| ID | Term |
|---|---|
| D009798 | Ocular Hypertension |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
Visual Field |
| The investigators anticipate to enroll the subjects over a period of 12 months. The estimated time required for data analysis is 6 months following enrollment of all subjects. |
| 15741814 | Background | Mansberger SL, Johnson CA, Cioffi GA, Choi D, Krishnadas SR, Srinivasan M, Balamurugan V, Kim U, Smith SD, Wilkins JH, Gritz DC. Predictive value of frequency doubling technology perimetry for detecting glaucoma in a developing country. J Glaucoma. 2005 Apr;14(2):128-34. doi: 10.1097/01.ijg.0000151883.07232.54. |
| 19225357 | Background | Nomoto H, Matsumoto C, Takada S, Hashimoto S, Arimura E, Okuyama S, Shimomura Y. Detectability of glaucomatous changes using SAP, FDT, flicker perimetry, and OCT. J Glaucoma. 2009 Feb;18(2):165-71. doi: 10.1097/IJG.0b013e318179f7ca. |