Recording Data Sheet:
All data and information of each woman in both groups (A & B) participated in this study were recorded in a recording data sheet (Appendix II).
Weight-Height scale:
A valid and reliable weight -height scale, with a range of 1 to 150 kilograms weight, and 1 to 200 centimeters height was used to measure the relevant subject's data.
Siemens Immulite Immunoassay System:
(Siemens Medical Solutions Diagnostics Immulite 1000,Los Angles, CA, 900-456900 U.S.A) to measure the serum Progesterone and Estradiol levels in both groups (A& B) using (TKE 21 Kit) for Estradiol and (TKPG 1 Kit) for Progesterone.
Biodex balance system:
Biodex Balance System (BBS), P.O. Box 702, Shirley, Ny 11967.It is an apparatus used to measure the dynamic balance. It utilizes dynamic multi axial platform. This platform allows approximately 20 degree inclination in 360 degree range and is interfaced with computer software. It measures the patient's ability to control the platform's angle of tilt, which is quantified as a variance from the center, as well as the degree of deflection over time at various stability levels as shown in (Fig. 6).
Stability levels allowed by the system ranged from one to eight. Stability level 8, allows the highest level of stability as it makes the platform to be the least tilted. On the other hand, stability level one represents the least level of stability and is more difficult for the subject to maintain stability on.
The test consists of recording the patient's ability to control the platform variance from a perfectly balanced position. A large variance is indicative of poor control and balance. Further definition is realized with the quantification of Anterior/ Posterior and Medial/Lateral responses.
Recording Data Sheet:
All data and information of each woman in both groups (A & B) participated in this study were recorded in a recording data sheet.
Weight-Height scale:
A valid and reliable weight -height scale, with a range of 1 to 150 kilograms weight, and 1 to 200 centimeters height was used to measure the relevant subject's data.
Siemens Immulite Immunoassay System:
(Siemens Medical Solutions Diagnostics Immulite 1000,Los Angles, CA, 900-456900 U.S.A) to measure the serum Progesterone and Estradiol levels in both groups (A& B) using (TKE 21 Kit) for Estradiol and (TKPG 1 Kit) for Progesterone.
Biodex balance system:
Biodex Balance System (BBS), P.O. Box 702, Shirley, Ny 11967.It is an apparatus used to measure the dynamic balance. It utilizes dynamic multi axial platform. This platform allows approximately 20 degree inclination in 360 degree range and is interfaced with computer software. It measures the patient's ability to control the platform's angle of tilt, which is quantified as a variance from the center, as well as the degree of deflection over time at various stability levels as shown in .
Stability levels allowed by the system ranged from one to eight. Stability level 8, allows the highest level of stability as it makes the platform to be the least tilted. On the other hand, stability level one represents the least level of stability and is more difficult for the subject to maintain stability on.
The test consists of recording the patient's ability to control the platform variance from a perfectly balanced position. A large variance is indicative of poor control and balance. Further definition is realized with the quantification of Anterior/ Posterior and Medial/Lateral responses.
The BBS Consists of the Following:
Stability levels:
- Biodex balance system has been allowed for eight stability levels, which has been ranged from stability level (1) to stability level (8).which allows setting up of the test parameters.
Stability indices:
III-Methods:
The evaluation procedures were explained in details for every woman in both groups (A&B) to increase her interest and co-operation.
Body Mass Index
The data of each woman in both groups were taken according to items of the recording data sheet then, the weight and height were measured and BMI was calculated according to the following equation BMI = Weight/Height (Kg/m2)
Blood sampling
Evening Blood sample was collected from each woman to limit the effect of hormone diurnal variations,For both groups samples have been collected at mid-luteal phase (20th to 23th days of the cycle), at Al-Madina Lab.
The sample was allowed to clot in water bath at room temperature.the serum was separated using a centrifuge at 4000 rmp for 15 min.Then using the TKE 21 and TKPG 1 Kits in a low temperature air conditioned room to measure serum Estradiol and Progesterone levels.
Biodex balance system:
The procedures were performed in dynamic balance lab at physical therapy faculty CairoUniversity.
Biodex Balance System used for assessment of the postural stability in female oral contraceptive users and non-users. The assessment was conducted for each woman individually.
The protocol of the work was explained to the woman before conducting this study.
A) Biodex balance system:
Operating the balance system:
Testing Protocol:
Preparatory step: the parameters of each examined woman (weight, height and age) as well as, test duration and stability level of the platform of the BBS were typed to the software of the device as shown in Fig. (8). All woman were asked to stand on the platform of the BBS in an erect posture as possible and kept it all through the test duration (i.e. stand on both feet, chin in, shoulders were leveled, as well as, retracted , back was straight and knees were drawn backward). Hence, the support handle rails and display screen were adjusted according to the height of each examined woman.
Centering step: with the aim of positioning the center of gravity (COG) of the subject at the middle of her base of support between the two feet and recoding the women's feet position. Centering was achieved by asking each woman to stand on the platform of the BBS while grasping the support handle rails by both hands while the platform was locked . Formerly, the platform was unlocked at stability level 8, the display screen showed a circle with a central cursor. At that time, the subject was asked to achieve a central position on the platform by shifting her feet position until she was able to keep the cursor (which represents the center of platform) centered on the circle that appeared on the display screen and correspondingly the platform was kept easily leveled.
- Once centering was achieved and the cursor was in the center of the display screen, each woman was instructed to maintain her feet at that position constant until the end of test procedures. At that time, the platform was locked again to allow recording the feet angles and heel's coordinates from the platform grid. The heel's coordinates were determined by finding the location of the center of the back of each heel in relation to X and Y coordinates of the platform, while the feet angles were determined by finding a line on the platform parallel to the 2nd metatarsal bone of each foot. Then, the feet angles and heels coordinates for each womanwere entered to the software of the BBS
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Oral contraceptive pills users | Active Comparator | The participants received treatment for 6 consecutive cycles. Each treatment cycle consisted of 3 weeks of ring/pill treatment followed by a 1-week pill-free period. The women were randomized in a 1:1 ratio to receive the COC containing 30 μg of EE and 3mg of drospirenone (Yasmin; Schering AG, Berlin, Germany) |
|
| control | No Intervention | no drugs |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| COC containing 30 μg of EE and 3mg of drospirenone | Drug | treatment for 6 consecutive cycles. Each treatment cycle consisted of 3 weeks of pill treatment followed by a 1-week pill-free period. |
| Measure | Description | Time Frame |
|---|---|---|
| overall joint stability | A) Biodex balance system: Testing procedures was done at mid-luteal phase (20th to 23th days of the cycle). Each woman was received verbal explanation about the test steps. The woman was tested without footwear and with eyes opened. Two test trials was done before specific test condition for the purpose of instrument familiarity prior to data collection. A high stability level (stability level 8) and reduced test time (20 sec) was chosen to avoid falling. Each woman was asked to perform two trial tests and their mean was calculated. Each test started with the balance platform in the locked position and standing on its center. | 6 months after pill use |
| Measure | Description | Time Frame |
|---|---|---|
| side effects | 6 months after pill use |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Ahmed Maged, MD | Kasr Alainy medical school | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Kasr Alainy medical school | Cairo | Cairo Governorate | 12151 | Egypt |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 28805601 | Derived | Maged AM, Salah E, Kamel AM, Hussein AM, Saad H, Meshaal H, Kamal WM. Effect of oral contraceptives on balance in women: A randomized controlled trial. Taiwan J Obstet Gynecol. 2017 Aug;56(4):463-466. doi: 10.1016/j.tjog.2017.02.003. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| C035144 | drospirenone |
| C534342 | drospirenone and ethinyl estradiol combination |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|