The main objective of this work is to validate the dynamometer LABIN in comparison with the technique of gold-standard reference JAMAR, in a healthy population.
The infringement of the prehension is frequent and impacts on the social and professional quality of life of the patients. There are numerous instruments measuring the strength of prehension. The JAMAR is a mechanical, hydraulic dynamometer, exploring in kilograms the maximal strength of the prehension. It is at present Gold Standard for the measure of the strength of prehension. There is for the moment no electronic known instrument exploring the endurance of the strength of prehension during an effort of tightening. This parameter would indeed be interesting for the exploration in geriatrics and in the neuromuscular pathologies.
This study justifies itself by the fact that the dynamometer LABIN should allow the evaluation of the muscular endurance of the strength of hand as complement of the peak of strength
Measure of the strength of prehension with JAMAR and LABIN according to the following protocol:
The order "Jamar then Labin" or Labin then Jamar is chosen by randomization. The operator encourages the subject to every test. The subject does not see the curve displaying.
Total duration of participation in the study for the patient: 30 minutes
Main analysis: the calculation of the coefficient of correlation (Pearson or Spearman with regard to the statistical distribution), coefficient of linen concordance and the coefficient of intra-classy correlation.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Jamar then Labin | Experimental | The order of the using of the dynamometers "Jamar then Labin" or "Labin then Jamar" is chosen by randomization |
|
| Labin then Jamar | Experimental | The order of the using of the dynamometers "Jamar then Labin" or "Labin then Jamar" is chosen by randomization |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Dynamometer LABIN | Device | LABIN is a prototype of dynamometer containing a handle of metal strength, connected with a sensor of pressure registering(recording) the applied strength and transmitting the data in a computer showing an IT curve of the strength according to time. |
| Measure | Description | Time Frame |
|---|---|---|
| Measure of the strength of prehension (in Kg). | measure of the strength of prehension in kilogram by using of the JAMAR ( hydraulic dynamometer), and the LABIN (electronic dynamometer provided with a sensor of pressure). | at day 1 |
| Measure | Description | Time Frame |
|---|---|---|
| The comfort of the using the dynamometer LABIN | A note of discomfort on Simple Verbal Scale from 0 to 10 (max.) is attributed by the subject | at day 1 |
| muscular endurance, estimated by dynamometer LABIN preservation of the strength for the LABIN |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Emmanuel COUDEYRE | University Hospital, Clermont-Ferrand | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| CHU Clermont-Ferrand | Clermont-Ferrand | 63003 | France |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 18796752 | Result | Hamilton GF, McDonald C, Chenier TC. Measurement of grip strength: validity and reliability of the sphygmomanometer and jamar grip dynamometer. J Orthop Sports Phys Ther. 1992;16(5):215-9. doi: 10.2519/jospt.1992.16.5.215. | |
| 8124439 | Result | Harkonen R, Harju R, Alaranta H. Accuracy of the Jamar dynamometer. J Hand Ther. 1993 Oct-Dec;6(4):259-62. doi: 10.1016/s0894-1130(12)80326-7. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D004194 | Disease |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Change from baselin in measure muscular endurance (The calculation of the horizontal length under the graphic curve which will be exploited by the colleagues of the IUT)
| at day 1 |
| 16110735 | Result | Bautmans I, Mets T. A fatigue resistance test for elderly persons based on grip strength: reliability and comparison with healthy young subjects. Aging Clin Exp Res. 2005 Jun;17(3):217-22. doi: 10.1007/BF03324600. |
| 10718222 | Result | Bellace JV, Healy D, Besser MP, Byron T, Hohman L. Validity of the Dexter Evaluation System's Jamar dynamometer attachment for assessment of hand grip strength in a normal population. J Hand Ther. 2000 Jan-Mar;13(1):46-51. doi: 10.1016/s0894-1130(00)80052-6. |
| 25531922 | Result | Martin-Ponce E, Hernandez-Betancor I, Gonzalez-Reimers E, Hernandez-Luis R, Martinez-Riera A, Santolaria F. Prognostic value of physical function tests: hand grip strength and six-minute walking test in elderly hospitalized patients. Sci Rep. 2014 Dec 22;4:7530. doi: 10.1038/srep07530. |