the aim of this study are to explore the characteristics of mean airway pressure, oscillatory amplitude and power spectral density (PSD) of oscillatory airway pressure that generate by various loaded and flow rate during expiration and inspiration in healthy subjects and to explore the best loaded and flow rate for airway secretion clearance using the BreatheMAX® device
For inspiratory group, the resistive load 3, 4, 5, 6 and 7 cm H2O were test with three flow rate: 0.2, 0.4, and 0.6 L/sec in each load. In each flow rate, the subjects were instructed to inspire as deeply as possible with steady flow rate for 3 seconds with end-inspiratory pause for 2-3 seconds through the inspiratory circuit and follow by passive exhalation. For expiratory group, the resistive load and flow rate were test similar inspiratory group. In each flow rate, the subjects were instructed to inspire as deeply as possible through the nose with end-inspiratory pause for 2-3 seconds and partially forced exhalation with reach to 1/3 of expiratory reserve volume (ERV) for at least 3 seconds through expiratory circuit
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Inspiratory group | Experimental | the subjects will be instructed to inspire as deeply as possible with steady flow rate for 3 seconds with end-inspiratory pause for 2-3 seconds through the inspiratory circuit and follow by passive exhalation |
|
| expiratory group | Experimental | the subjects will be instructed to inspire as deeply as possible through the nose with end-inspiratory pause for 2-3 seconds and partially forced exhalation with reach to 1/3 of expiratory reserve volume (ERV) for at least 3 seconds through expiratory circuit |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| BreatheMAX breathing device | Device |
|
| Measure | Description | Time Frame |
|---|---|---|
| PSD of oscillatory airway pressure | 5 seconds during inspiration and expiration testing period |
| Measure | Description | Time Frame |
|---|---|---|
| mean airway pressure | 5 seconds during inspiration and expiration testing period | |
| oscillatory amplitude | 5 seconds during inspiration and expiration testing period |
Not provided
Inclusion Criteria:
Exclusion Criteria:
- fever
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| sujittra Kluayhomthong, master degree | faculty of associated medical science, KhonKaen University, Thailand 40002 | Principal Investigator |