Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
To prospectively compare clinical outcomes using straight (perpendicular) versus angled trocar insertion during 27 gauge pars plana vitrectomy surgery for epiretinal membrane
Primary Endpoints:
Sclerotomy suture rates and incidence of suture blebs at the end of 27 gauge MIVS.
Secondary Endpoints:
Rate of postoperative wound-related complications such as hypotony, choroidal detachments, endophthalmitis, and sclerotomy-related retinal tears with a minimum follow-up of 30 days.
Microincision vitrectomy surgery (MIVS) has largely replaced use of conventional, 20-gauge vitrectomy, offering more rapid visual recovery, decreased postoperative pain and inflammation, and reduced surgical time with use of smaller diameter instruments1. Most recently, 27 gauge vitrectomy instrumentation has been introduced2, offering an additional small gauge option to the currently available 23, 25, or 25+ gauge systems.
Initial experience with small gauge MIVS yielded mixed results, with early reports noting increased rates of wound-related postoperative complications including hypotony, choroidal detachments, endophthalmitis, and sclerotomy-related retinal tears3,4. However, with more experience and instrument modifications, outcomes with MIVS improved1,3. In a 2010 Ophthalmic Technology Assessment report by the American Academy of Ophthalmology, outcomes of MIVS were found comparable to that of 20 gauge vitrectomy benchmarks5.
Prior studies have established that a two-stage, angled incision results in improved wound integrity with 23, 25, and 25+ MIVS systems6,7, helping to prevent complications such as post-operative endophthalmitis and hypotony. However, in the two clinical series describing outcomes of 27 gauge MIVS, a one-stage, perpendicular wound construction was performed without complication in a series of 31 patients2,8. Thus far, direct comparison between wound construction techniques (one-stage, perpendicular or two-stage, angled) has not been evaluated.
The purpose of this study is to prospectively compare clinical outcomes using straight, one-stage (perpendicular) versus angled, two-stage trocar insertion during 27 gauge minimally invasive vitrectomy surgery (MIVS). The design of the study will be a randomized, clinical trial. Primary outcomes will be sclerotomy suture rates and incidence of suture blebs at the end of 27 gauge MIVS surgery for epiretinal membrane and macular pucker indications (no air or gas tamponade). Secondary endpoints will include rate of postoperative wound-related complications such as hypotony, choroidal detachments, endophthalmitis, and sclerotomy-related retinal tears with a minimum of 30 days follow-up.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Angled incision | Active Comparator | Patients in this arm will undergo 27-gauge vitrectomy wound construction using angled (tunnel-like) incisions for trocar entry. |
|
| Straight Incision | Active Comparator | Patients in this arm undergo 27-gauge vitrectomy wound construction using straight (perpendicular) incisions for trocar entry. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 27-gauge vitrectomy wound construction | Device | Conventional, 3-port pars plana vitrectomy with membrane peeling is performed for epiretinal membrane indication. Angled and straight trocar entry will be directly compared. |
| Measure | Description | Time Frame |
|---|---|---|
| Rate of sclerotomy site suturing and suture bleb formation | Minimum follow-up 30 days. |
| Measure | Description | Time Frame |
|---|---|---|
| Rate of post-operative, wound related complications | Rate of complications including hypotony, choroidal detachment, and endophthalmitis | Minimum follow-up of 30 days |
| Change in mean intraocular pressure |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Carl D Regillo, MD | Wills Eye Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mid Atlantic Retina- Wills Eye Institute | Philadelphia | Pennsylvania | 19107 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 21236459 | Background | Thompson JT. Advantages and limitations of small gauge vitrectomy. Surv Ophthalmol. 2011 Mar-Apr;56(2):162-72. doi: 10.1016/j.survophthal.2010.08.003. Epub 2011 Jan 14. | |
| 19880185 | Background | Oshima Y, Wakabayashi T, Sato T, Ohji M, Tano Y. A 27-gauge instrument system for transconjunctival sutureless microincision vitrectomy surgery. Ophthalmology. 2010 Jan;117(1):93-102.e2. doi: 10.1016/j.ophtha.2009.06.043. Epub 2009 Oct 31. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Date | Date Unknown |
|---|---|---|
| Release | Nov 15, 2017 | |
| Reset | Dec 13, 2017 |
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Nov 15, 2017 | Dec 13, 2017 |
| ID | Term |
|---|---|
| D019773 | Epiretinal Membrane |
| ID | Term |
|---|---|
| D012164 | Retinal Diseases |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Measured in mm Hg by tonometry
| Minimum follow-up of 30 days |
| 19390437 | Background | Spirn MJ. Comparison of 25, 23 and 20-gauge vitrectomy. Curr Opin Ophthalmol. 2009 May;20(3):195-9. doi: 10.1097/ICU.0b013e328329eaea. |
| 17435424 | Background | Chen E. 25-Gauge transconjunctival sutureless vitrectomy. Curr Opin Ophthalmol. 2007 May;18(3):188-93. doi: 10.1097/ICU.0b013e328133889a. |
| 20816248 | Background | Recchia FM, Scott IU, Brown GC, Brown MM, Ho AC, Ip MS. Small-gauge pars plana vitrectomy: a report by the American Academy of Ophthalmology. Ophthalmology. 2010 Sep;117(9):1851-7. doi: 10.1016/j.ophtha.2010.06.014. |
| 25946694 | Background | Rizzo S, Barca F, Caporossi T, Mariotti C. Twenty-seven-gauge vitrectomy for various vitreoretinal diseases. Retina. 2015 Jun;35(6):1273-8. doi: 10.1097/IAE.0000000000000545. No abstract available. |
| 18947818 | Background | Gupta OP, Maguire JI, Eagle RC Jr, Garg SJ, Gonye GE. The competency of pars plana vitrectomy incisions: a comparative histologic and spectrophotometric analysis. Am J Ophthalmol. 2009 Feb;147(2):243-250.e1. doi: 10.1016/j.ajo.2008.08.025. Epub 2008 Oct 23. |
| 23533705 | Background | Teixeira A, Rezende FA, Salaroli C, Souza N, Sousa BA, Allemann N. In vivo comparison of 23- and 25-gauge sutureless vitrectomy incision architecture using spectral domain optical coherence tomography. J Ophthalmol. 2013;2013:347801. doi: 10.1155/2013/347801. Epub 2013 Mar 4. |