Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The left atrium appendage (LAA) is a remnant of the original embryonic left atrium formed during the third week of gestation. LAA is believed to function as a decompression chamber during left ventricular systole and other periods when left atrial pressure is elevated. The LAA is also a major endocrine organ and is the main producer of ANP (atrial natriuretic peptide) in the human heart. The ANP concentration is 40 times higher in the LAA walls than in the rest of the atrial wall. A study of patients having undergone the maze procedure and associated LAA removal found a significantly lower ANP secretion and an increase in salt and water retention. Whether this could eventually lead to hypertension or heart failure symptoms is not known.
Removal of the LAA is routinely performed during antiarrhythmic surgical techniques ("MAZE surgery") to reduce the risk of subsequent LAA thrombus. Furthermore, new percutaneous ablation techniques target LAA to reduce further risks of atrial fibrilation recurrences. However, in addition to effects on diastolic atrial function and atrial natriuretic peptide (ANP) secretion, this could potentially reduce stroke volume and cardiac output and may thus promote heart failure. Its removal could be particularly detrimental in patients with existing heart failure and high intraatrial pressure, as it would further promote pulmonary congestion and also reduce their cardiac output.
The study will be conducted at the CHU Brugmann Hospital, with collaboration between cardiac surgery and cardiology wards. Subjects referred for non valvular cardiac surgery will be prospectively included during the first 6 months following the onset of the protocol. Echocardiographic and invasive data will be collected simultaneously.
The goals of the study are:
A significant role of the LAA in the cardiac hemodynamic including the left ventricle outflow might have different clinical implications and will raise questions about:
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Non valvular cardiac surgery | Experimental | The study will be conducted at the CHU Brugmann Hospital, with collaboration between cardiac surgery and cardiology wards. Subjects referred for non valvular cardiac surgery will be prospectively included during the first 6 months following the onset of the protocol. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Transesophageal echocardiogram | Device | All patients will undergo a standard surgical procedure by the surgical team of CHU Brugmann. A transesophageal echocardiogram (TEE) will be performed and the TEE probe will stay continuously during the entire procedure, to allow all necessary measurements. |
| Measure | Description | Time Frame |
|---|---|---|
| Left atrium (LA) dP/dt max | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. | Baseline (before LAA clamping) |
| Left atrium dP/dt max | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. | 5 minutes after LAA clamping |
| Left atrium output | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA). | Baseline (before LAA clamping) |
| Left atrium output | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA). |
| Measure | Description | Time Frame |
|---|---|---|
| Area fractional shortening (AFS) of the left atrium appendage (LAA) | Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: AFS 2CME90°= (Amax-Amin)/Amax. | Baseline (before LAA clamping) |
| Area fractional shortening (AFS) of the left atrium appendage (LAA) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Pierre Wauthy, MD | CHU Brugmann | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| CHU Brugmann | Brussels | 1020 | Belgium |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 12651054 | Background | Pritchett AM, Jacobsen SJ, Mahoney DW, Rodeheffer RJ, Bailey KR, Redfield MM. Left atrial volume as an index of left atrial size: a population-based study. J Am Coll Cardiol. 2003 Mar 19;41(6):1036-43. doi: 10.1016/s0735-1097(02)02981-9. | |
| 12695291 | Background | Moller JE, Hillis GS, Oh JK, Seward JB, Reeder GS, Wright RS, Park SW, Bailey KR, Pellikka PA. Left atrial volume: a powerful predictor of survival after acute myocardial infarction. Circulation. 2003 May 6;107(17):2207-12. doi: 10.1161/01.CIR.0000066318.21784.43. Epub 2003 Apr 14. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001733 | Bites and Stings |
| ID | Term |
|---|---|
| D011041 | Poisoning |
| D064419 | Chemically-Induced Disorders |
| D014947 | Wounds and Injuries |
Not provided
Not provided
| ID | Term |
|---|---|
| D017548 | Echocardiography, Transesophageal |
| D004452 | Echocardiography |
| ID | Term |
|---|---|
| D057791 | Cardiac Imaging Techniques |
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Thermistor-tipped catheter | Device | All patients will undergo a standard surgical procedure by the surgical team of CHU Brugmann.During the procedure, a thermistor-tipped catheter (model 93A-131-7F, Edwards, Santa Ana, CA) will be inserted into the pulmonary artery to measure right atrial pressure (Pra), pulmonary arterial pressure (Ppa), Ppao and thermodilution cardiac output. Ringer's lactate will be infused to maintain an occluded pulmonary arterial pressure (Ppao) of 8-10 mmHg. |
|
| Pressure/volume catheter | Device | All patients will undergo a standard surgical procedure by the surgical team of CHU Brugmann.During the procedure, a pressure/volume catheter (CD Leicom, Zoetermeer, Netherland) will be placed in the left ventricle through a left superior pulmonary vein purse string, in order to measure alternatively LV pressure/volume loops and LA pressure. |
|
| Transthoracic echocardiography | Device | A complete transthoracic echocardiography will be performed the day before the surgical procedure. It will establish the presence of the inclusion and exclusion criteria, as stipulated above. This will be done using a Philips IE33 echocardiograph (Koninklijke Philips Electronics N.V., Netherlands). During the surgical procedure, a transesophageal echocardiogram will be performed, using an Acuson Sequoia system (Siemens AG, Germany). |
|
| 5 minutes after LAA clamping |
| Left atrium contractility index (dP/dt max)/P | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. | Baseline (before LAA clamping) |
| Left atrium contractility index (dP/dt max)/P | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. | 5 minutes after LAA clamping |
| Left ventricle (LV) dP/dt max | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. | Baseline (before LAA clamping) |
| Left ventricle dP/dt max | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. | 5 minutes after LAA clamping |
| Left ventricle output | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA). | Baseline (before LAA clamping) |
| Left ventricle output | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. The cardiac output will be measured by thermodilution (REF-1 computer, Edwards, Irvine, CA). | 5 minutes after LAA clamping |
| LV contractility index (dP/dt max)/P | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. LV contractility will be estimated from the slope of the end-systolic pressure-volume relation. | Baseline (before LAA clamping) |
| LV contractility index (dP/dt max)/P | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. LV contractility will be estimated from the slope of the end-systolic pressure-volume relation. | 5 minutes after LAA clamping |
| Occluded pulmonary arterial pressure (Ppao) | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. | Baseline (before LAA clamping) |
| Occluded pulmonary arterial pressure (Ppao) | Fluid-filled catheter-derived pressures will be zero-referenced at mid-chest level and processed using disposable transducers (Baxter-Bentley, Uden, the Netherlands) and a Sirecust 404 monitoring system (Siemens, Erlangen, Germany). Micromanometer-derived pressures and conductance catheter data will be processed using a Leicom INCA intracardiac monitor (CD Leycom, Zoetermeer, Netherlands). All pressures and volume signals will be digitalized at 200 Hz and stored in a PC for off-line analysis. | 5 minutes after LAA clamping |
Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: AFS 2CME90°= (Amax-Amin)/Amax. |
| 5 minutes after LAA clamping |
| Ejection volume of the LAA (left atrium appendage) | Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: LAA ejection volume= 3,14*D1*D2*TVI PW LAA/4, where D1 and D2 are the diameters of the opening of the LAA at 0° and 90° | Baseline (before LAA clamping) |
| Ejection volume of the LAA (left atrium appendage) | Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: LAA ejection volume= 3,14*D1*D2*TVI PW LAA/4, where D1 and D2 are the diameters of the opening of the LAA at 0° and 90° | 5 minutes after LAA clamping |
| Stroke volume | Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: Stroke volume= 3,14D²*Aortic PW TVI /4, where D is the LVOT (left ventricular outflow tract)diameter in A3C. | Baseline (before LAA clamping) |
| Stroke volume | Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). Computed with the following formula: Stroke volume= 3,14D²*Aortic PW TVI /4, where D is the LVOT (left ventricular outflow tract) diameter in A3C. | 5 minutes after LAA clamping |
| Amplitude of the emptying pulse wave of the LAA (left atrium appendage) | Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). 2C ME 90° measure | Baseline (before LAA clamping) |
| Amplitude of the emptying pulse wave of the LAA (left atrium appendage) | Transesophageal echocardiography data (Acuson Sequoia system - Siemens AG, Germany). 2C ME 90° measure | 5 minutes after LAA clamping |
| TVI (Aortic Time-Velocity Integral) of the emptying pulse wave of the LAA (left atrium appendage) | Transgastric or deep transgastric aortic Pulse Wave Doppler. 2C ME 90° measure | Baseline (before LAA clamping) |
| TVI (Aortic Time-Velocity Integral) of the emptying pulse wave of the LAA (left atrium appendage) | Transgastric or deep transgastric aortic Pulse Wave Doppler. 2C ME 90° measure | 5 minutes after LAA clamping |
| Amplitude of the mitral A wave | Amplitude A wave: measured with DTI (Tissue Doppler ) 4C ME 0° lateral ring | Baseline (before LAA clamping) |
| Amplitude of the mitral A wave | Amplitude A wave: measured with DTI (Tissue Doppler ) 4C ME 0° lateral ring | 5 minutes after LAA clamping |
| TVI (Aortic Time-Velocity Integral) of the left upper pulmonary vein (LUPV) | Measured by aortic Pulse Wave (PW) Doppler flow | Baseline (before LAA clamping) |
| TVI (Aortic Time-Velocity Integral) of the left upper pulmonary vein (LUPV) | Measured by aortic Pulse Wave (PW) Doppler flow | 5 minutes after LAA clamping |
| 14522480 | Background | Tsang TS, Barnes ME, Gersh BJ, Takemoto Y, Rosales AG, Bailey KR, Seward JB. Prediction of risk for first age-related cardiovascular events in an elderly population: the incremental value of echocardiography. J Am Coll Cardiol. 2003 Oct 1;42(7):1199-205. doi: 10.1016/s0735-1097(03)00943-4. |
| 16904549 | Background | Osranek M, Fatema K, Qaddoura F, Al-Saileek A, Barnes ME, Bailey KR, Gersh BJ, Tsang TS, Zehr KJ, Seward JB. Left atrial volume predicts the risk of atrial fibrillation after cardiac surgery: a prospective study. J Am Coll Cardiol. 2006 Aug 15;48(4):779-86. doi: 10.1016/j.jacc.2006.03.054. Epub 2006 Jul 25. |
| 12480035 | Background | Tsang TS, Barnes ME, Gersh BJ, Bailey KR, Seward JB. Left atrial volume as a morphophysiologic expression of left ventricular diastolic dysfunction and relation to cardiovascular risk burden. Am J Cardiol. 2002 Dec 15;90(12):1284-9. doi: 10.1016/s0002-9149(02)02864-3. |
| 14665520 | Background | Stollberger C, Schneider B, Finsterer J. Elimination of the left atrial appendage to prevent stroke or embolism? Anatomic, physiologic, and pathophysiologic considerations. Chest. 2003 Dec;124(6):2356-62. doi: 10.1378/chest.124.6.2356. |
| 10525506 | Background | Al-Saady NM, Obel OA, Camm AJ. Left atrial appendage: structure, function, and role in thromboembolism. Heart. 1999 Nov;82(5):547-54. doi: 10.1136/hrt.82.5.547. |
| 11997272 | Background | Sievert H, Lesh MD, Trepels T, Omran H, Bartorelli A, Della Bella P, Nakai T, Reisman M, DiMario C, Block P, Kramer P, Fleschenberg D, Krumsdorf U, Scherer D. Percutaneous left atrial appendage transcatheter occlusion to prevent stroke in high-risk patients with atrial fibrillation: early clinical experience. Circulation. 2002 Apr 23;105(16):1887-9. doi: 10.1161/01.cir.0000015698.54752.6d. |
| 7874938 | Background | Akosah KO, Funai JT, Porter TR, Jesse RL, Mohanty PK. Left atrial appendage contractile function in atrial fibrillation. Influence of heart rate and cardioversion to sinus rhythm. Chest. 1995 Mar;107(3):690-6. doi: 10.1378/chest.107.3.690. |
| 17198808 | Background | Kamohara K, Popovic ZB, Daimon M, Martin M, Ootaki Y, Akiyama M, Zahr F, Cingoz F, Ootaki C, Kopcak MW Jr, Dessoffy R, Liu J, Thomas JD, Gillinov AM, Fukamachi K. Impact of left atrial appendage exclusion on left atrial function. J Thorac Cardiovasc Surg. 2007 Jan;133(1):174-81. doi: 10.1016/j.jtcvs.2006.08.057. |
| 16376782 | Background | Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ; Chamber Quantification Writing Group; American Society of Echocardiography's Guidelines and Standards Committee; European Association of Echocardiography. Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr. 2005 Dec;18(12):1440-63. doi: 10.1016/j.echo.2005.10.005. No abstract available. |
| D014463 | Ultrasonography |
| D006334 | Heart Function Tests |
| D003935 | Diagnostic Techniques, Cardiovascular |