Obstructive sleep apnea (OSA) is the most common type of sleep apnea. OSA affects an estimated 18-40 million adults and 0.7-3% of all children in the US. The marketplace currently does not have an affordable, easy-to-use, over-the-counter, home-based OSA screening device. An affordable, available, FDA-approved and easy-to-use over-the-counter OSA screening tool would allow greater screening of at-risk individuals, especially in underserved communities with low socioeconomic status, hopefully encouraging a greater proportion of such individuals to seek treatment for their condition. The specific goal of this project is to compare the Zansors® micro sleep sensor screening device against gold-standard polysomnography to establish the device's preliminary validity to screen for OSA accurately.
Obstructive Sleep Apnea (OSA) results in tiredness, depression and fatigue, and has several associated common comorbidities. It is believed that over 80% of OSA remains undiagnosed. Poorer and disadvantaged communities are at higher risk for sleep disorders, including OSA, even after accounting for other risk factors. The gold-standard method for diagnosing OSA is in-laboratory polysomnography; however, this procedure is generally available only to patients with health insurance due to its high cost. As a result, communities at particularly high risk for OSA are less likely to have this serious sleep disorder appropriately diagnosed and treated.
An affordable, available, FDA-approved and easy-to-use over-the-counter OSA screening tool would allow greater screening of at-risk individuals, especially in underserved communities with low socioeconomic status, hopefully encouraging a greater proportion of such individuals to seek treatment for their condition. Zansors® has developed a bioengineered, semiconductor prototype that measures breathing and movement during sleep. It is a 1.5 x 2.5 x 0.2 inch wireless package using four key technologies:
The product will be designed as an FDA-approved over-the-counter device that the patient can wear during sleep and wake up with a color score of red, yellow, or green depending on their sleep apnea status. The features of this product include that it is home-based; easy to use; non-invasive; wireless; disposable; low cost ($20-50); and presents easily understandable test results. However, such a device must first be validated against gold-standard polysomnography.
The specific goal of this project is to compare the Zansors® micro sleep sensor screening device against gold-standard polysomnography to establish the device's preliminary validity to screen for OSA accurately.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Zansors® sleep screening device | Experimental | Zansors device compared to overnight polysomnography |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Zansors® sleep screening device | Device | Intervention is the validation of a sleep apnea screening device against the gold-standard assessment of in-laboratory polysomnography |
|
| Measure | Description | Time Frame |
|---|---|---|
| Specificity | Specificity of Zansors' device to detect apnea events compared to gold-standard polysomnography over an 8-hour period of sleep at 30-second intervals | 8 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Sensitivity | Sensitivity of Zansors' device to detect apnea events compared to gold-standard polysomnography over an 8-hour period of sleep at 30-second intervals | 8 hours |
| Positive Predictive Value (PPV) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| J. Todd Arnedt, PhD | University of Michigan | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Michigan | Ann Arbor | Michigan | 48109 | United States |
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Zansors® Sleep Screening Device | Zansors device compared to overnight polysomnography Zansors® sleep screening device: Intervention is the validation of a sleep apnea screening device against the gold-standard assessment of in-laboratory polysomnography |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Zansors® Sleep Screening Device | Zansors device compared to overnight polysomnography Zansors® sleep screening device: Intervention is the validation of a sleep apnea screening device against the gold-standard assessment of in-laboratory polysomnography |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Specificity | Specificity of Zansors' device to detect apnea events compared to gold-standard polysomnography over an 8-hour period of sleep at 30-second intervals | Posted | Number | percentage of true negatives | 8 hours |
|
|
8 hours
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Zansors® Sleep Screening Device | Zansors device compared to overnight polysomnography Zansors® sleep screening device: Intervention is the validation of a sleep apnea screening device against the gold-standard assessment of in-laboratory polysomnography |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| J. Todd Arnedt, PhD | University of Michigan | 734-615-8666 | tarnedt@med.umich.edu |
Not provided
| ID | Term |
|---|---|
| D020181 | Sleep Apnea, Obstructive |
| ID | Term |
|---|---|
| D012891 | Sleep Apnea Syndromes |
| D001049 | Apnea |
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
PPV of Zansors' device to detect apnea events compared to gold-standard polysomnography over an 8-hour period of sleep at 30-second intervals
| 8 hours |
| Negative Predictive Value (NPV) | NPV of Zansors' device to detect apnea events compared to gold-standard polysomnography over an 8-hour period of sleep at 30-second intervals | 8 hours |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
|
| Secondary | Sensitivity | Sensitivity of Zansors' device to detect apnea events compared to gold-standard polysomnography over an 8-hour period of sleep at 30-second intervals | Posted | Number | percentage of true positives | 8 hours |
|
|
|
| Secondary | Positive Predictive Value (PPV) | PPV of Zansors' device to detect apnea events compared to gold-standard polysomnography over an 8-hour period of sleep at 30-second intervals | Posted | Number | positive predictive value | 8 hours |
|
|
|
| Secondary | Negative Predictive Value (NPV) | NPV of Zansors' device to detect apnea events compared to gold-standard polysomnography over an 8-hour period of sleep at 30-second intervals | Posted | Number | negative predictive value | 8 hours |
|
|
|
| 0 |
| 52 |
| 0 |
| 52 |
Not provided
Not provided
Not provided
| D020919 |
| Sleep Disorders, Intrinsic |
| D020920 | Dyssomnias |
| D012893 | Sleep Wake Disorders |
| D009422 | Nervous System Diseases |