The closed-loop delivery system is composed of an insulin pump, a continuous glucose sensor and a dosing algorithm that calculates the insulin dose to infuse based on sensor readings. Pramlintide is a drug and an analog of amylin, a hormone that is co-secreted with insulin in healthy individuals, and is deficient in people with type 1 diabetes. Co-injection of pramlintide with insulin at meal times improves glucose control in type 1 diabetes. Literature data suggests that regular insulin may better match the effect of pramlintide compared to rapid insulin in regulating post-prandial glucose levels.
The purpose of this study is to compare the effectiveness of 3 strategies to control your day-and-night glucose levels:
The primary hypotheses are:
The closed-loop delivery system is composed of an insulin pump, a continuous glucose sensor and a dosing algorithm that calculates the insulin dose to infuse based on sensor readings. Pramlintide is a drug and an analog of amylin, a hormone that is co-secreted with insulin in healthy individuals, and is deficient in people with type 1 diabetes. Co-injection of pramlintide with insulin at meal times improves glucose control in type 1 diabetes.
Literature data suggests that the pharmacodynamics of regular insulin may better match the effect of pramlintide compared to the pharmacodynamics of fast-acting insulin. Moreover, the cost of regular insulin is significantly lower than fast-acting insulin. Therefore, if a similar (or better) glucose profile can be achieved with regular insulin-plus-pramlintide compared to fast-acting insulin-plus-pramlintide, then a co-formulation employing regular insulin should be prioritized.
Therefore, in this protocol, we aim to assess the effect of the simultaneous, closed-loop, basal-bolus infusion of pramlintide with insulin at a fixed ratio in controlling glucose levels. In the first experimental arm, we propose to infuse pramlintide with fast-acting insulin. In the second experimental arm, pramlintide will be infused with regular insulin. The control arm will be fast-acting insulin-alone closed-loop system.
The aim of the study is to assess the efficacy of the simultaneous, closed-loop, basal-bolus infusion of pramlintide with fast-acting insulin at a fixed ratio and pramlintide with regular insulin at a fixed ratio in controlling glucose levels compared to fast-acting insulin-alone closed-loop infusion.
The investigators aim to conduct a randomized, three-way, crossover trial to compare the efficacy of 1) fast-acting insulin-plus-pramlintide closed-loop delivery, 2) regular insulin-plus-pramlintide closed-loop delivery, and 3) fast-acting insulin-alone closed-loop delivery in regulating glucose levels over a period of 24 hours in a study on adults in inpatient settings. Insulin (fast-acting and regular) and pramlintide are given with fixed ratio (6 µg of pramlintide for each unit of insulin).
Before each 24-hour intervention visit, the participant's insulin therapy (basal rates and insulin-to-carbohydrate ratios) will be optimized for a minimum of 10 days, with a target of 14 days.
There will be a wash-out period of 0 to 42 days between the three intervention arms (termination of 24-hr intervention and start of next optimization period).
The primary hypotheses are:
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Rapid Insulin-alone closed-loop delivery | Active Comparator | Rapid Insulin will be delivered by subcutaneous infusion. Interventions: 24-hour inpatient intervention Drug: Rapid acting Insulin (aspart, lispro, glulisine) |
|
| Rapid Insulin-plus-pramlintide closed-loop delivery | Experimental | Rapid insulin and pramlintide will be delivered by subcutaneous infusion using a fixed ratio (6 µg pramlintide/unit insulin). Interventions: 24-hour inpatient intervention Drug: Rapid acting Insulin (aspart, lispro, glulisine) Drug: Pramlintide |
|
| Regular Insulin-plus-pramlintide closed-loop delivery | Experimental | Regular insulin and pramlintide will be delivered by subcutaneous infusion using a fixed ratio (6 µg pramlintide/unit insulin). Interventions: 24-hour inpatient intervention Drug: Regular Insulin (humulin R) Drug: Pramlintide |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 24-hour inpatient intervention | Other | Subjects will be admitted at the research facility at 7:30. A cannula will be inserted into an arm or a hand vein for blood sampling purposes. Each 24-hour intervention visit includes 3 standardized meals (8:00, 12:00, and 17:00), an evening snack (21:00) and an overnight stay. The glucose level as measured by the real time sensor will be entered manually into the computer every 10 minutes. The insulin and pramlintide pumps' infusion rates will then be changed manually based on the computer generated recommendation, while still maintaining the ratio. The computer generated recommendations are based on a predictive algorithm. |
| Measure | Description | Time Frame |
|---|---|---|
| Percentage of time of plasma glucose levels spent in target range. Target range is defined to be between 3.9 and 10.0 mmol/L of fast-acting insulin-plus-pramlintide closed-loop delivery vs. fast-acting insulin-alone closed-loop delivery. | Up to 24 hours | |
| Percentage of time of plasma glucose levels spent in target range. Target range is defined to be between 3.9 and 10.0 mmol/L of regular insulin-plus-pramlintide closed-loop delivery vs. fast-acting insulin-alone closed-loop delivery. | Up to 24 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Percentage of time of plasma glucose levels spent in target range, comparing fast-acting insulin-plus-pramlintide closed-loop delivery vs. regular insulin-plus-pramlintide closed-loop delivery. | Up to 24 hours | |
| Percentage of time (8:00-8:00) of plasma glucose levels spent: a. 3.9-7.8 mmol/L; b. 3.9-10 mmol/L; c. <3.9 mmol/L; d. <3.3 mmol/L; e. <2.8 mmol/L; f. >7.8 mmol/L; g. >10 mmol/L; h. >13.9 mmol/L; i. >16.7 mmol/L |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Ahmad Haidar | McGill University | Principal Investigator |
| Laurent Legault | McGill University Health Centre/Research Institute of the McGill University Health Centre | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| McGill University Health Centre | Montreal | Quebec | Canada |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31974099 | Derived | Haidar A, Tsoukas MA, Bernier-Twardy S, Yale JF, Rutkowski J, Bossy A, Pytka E, El Fathi A, Strauss N, Legault L. A Novel Dual-Hormone Insulin-and-Pramlintide Artificial Pancreas for Type 1 Diabetes: A Randomized Controlled Crossover Trial. Diabetes Care. 2020 Mar;43(3):597-606. doi: 10.2337/dc19-1922. Epub 2020 Jan 23. | |
| 31613140 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Dec 12, 2017 | Jan 2, 2018 | Prot_SAP_000.pdf |
| ICF | No | No | Yes | Informed Consent Form | Dec 12, 2017 | Jan 2, 2018 | ICF_001.pdf |
Not provided
| ID | Term |
|---|---|
| D003922 | Diabetes Mellitus, Type 1 |
| D007333 | Insulin Resistance |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Up to 24 hours |
| Percentage of overnight time (23:00-8:00) of plasma glucose levels: a. 3.9-7.8 mmol/L; b. 3.9-10 mmol/L; c. <3.9 mmol/L; d. <3.3 mmol/L; e. <2.8 mmol/L; f. >7.8 mmol/L; g. >10 mmol/L; h. >13.9 mmol/L; i. >16.7 mmol/L | Up to 24 hours |
| Standard deviation of glucose levels as a measure of glucose variability. | Up to 24 hours |
| Total insulin delivery. | Up to 24 hours |
| Total pramlintide delivery. | Up to 24 hours |
| Mean plasma glucose level during: a. the overall study period; b. overnight period. | Up to 24 hours |
| Mean plasma insulin concentration. | Up to 24 hours |
| Mean plasma glucagon concentration. | Up to 24 hours |
| Mean plasma amylin concentration. | Up to 24 hours |
| Number of subjects experiencing hypoglycemia requiring oral treatment during: a. the overall study period; b. the night. | Up to 24 hours |
| Gastrointestinal symptoms during the treatment optimization (i.e., the minimum 10 days prior to the 24-hour closed-loop visits) and during the 24-hour closed-loop visits. | Up to 24 hours |
| Tsoukas M, Rutkowski J, El-Fathi A, Yale JF, Bernier-Twardy S, Bossy A, Pytka E, Legault L, Haidar A. Accuracy of FreeStyle Libre in Adults with Type 1 Diabetes: The Effect of Sensor Age. Diabetes Technol Ther. 2020 Mar;22(3):203-207. doi: 10.1089/dia.2019.0262. Epub 2020 Jan 23. |
| D004700 | Endocrine System Diseases |
| D001327 | Autoimmune Diseases |
| D007154 | Immune System Diseases |
| D006946 | Hyperinsulinism |